Search
Search Results
##search.searchResults.foundPlural##
-
Evaluating the masking ability of CAD/CAM hybrid ceramics with different thicknesses
Aim: A discoloration existing under the restoration can affect the final restoration color, and various techniques can be used to address this situation. The aim of this study was to investigate the masking ability of the substructure, color of different hybrid CAD/CAM ceramics in various thicknesses. Methodology: A total of 120 samples were produced from 4 different CAD/CAM hybrid ceramic blocks (Cerec blocs, GC Cerasmart, Vita Enamic, 3M Lava Ultimate) in 1, 1.5 and 2 mm thickness. The samples were sliced with 100 N pressure in a low-speed precision cutting device under water cooling. The specimens were placed over the neutral grey background for initial spectrophotometric measurements. A3 color posterior nanohybrid composite (14 X 7 X 1 mm) was preferred to mimic discoloration in the substructure. The cementation procedure of composite and the CAD/CAM hybrid ceramic complex was standardized under 10 N continuous pressure and was performed using a dual cured resin cement. All samples were incubated at 37 °C for 24 hours in incubator after cementation. And the second spectrophotometeric measurement was done via the L*, a*, and b* color attributes of the complex specimens. Additionally, ΔE* values were calculated to determine the color differences between each group. Kruskal Wallis test was used for statistical analysis and Dunn’s test was used for group comparison. Significance was evaluated at least p <0.05. Results: It was found that thickness of the ceramics increases, the substructure color is better masked and the thickness made a statistically significant difference on the masking ability (p<0.01). For 1 mm thick samples, the highest ΔE* value was found in Cerec blocs with 9.36, while the lowest value was found in GC Cerasmart as 4.27. Conclusion: Within the limitations of this study, it was concluded that the tested CAD/CAM hybrid ceramics showed better masking ability than Cerec blocs. How to cite this article: Ünalan Değirmenci B, Wahid WF. Evaluating the masking ability of CAD/CAM hybrid ceramics with different thicknesses. Int Dent Res 2021;11(2):114-20. https://doi.org/10.5577/intdentres.2021.vol11.no1.9 Linguistic Revision: The English language in this manuscript has been checked by at least two professional editors, both native speakers of English.CAD-CAM, ceramics, tooth discolorationBeyza Ünalan Değirmenci, Farhad Wahid Rasool31.08.2021114-120 -
Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays
Aim: The aim of the study was to evaluate the fracture resistance and microleakage of different CAD-CAM inlay restorations. Methodology: Inlay restorations from nine restorative materials as monolithic zirconia (TZI), resin nano ceramic (LU), hybrid ceramic (VE), feldspathic ceramic (CB), zirconia reinforced lithium silicate (VS), lithium disilicate (e.max), leucite reinforced glass ceramic (Emp), resin ceramic (GCS), and conventional composite resin (CR) were used (n=10). For evaluating the fracture resistance, restorations were cemented to resin teeth and subjected to thermomechanical aging. The data of fracture resistance were analyzed using One-way Analysis of Variance (ANOVA) and Games-Howel tests (a=0.05). For evaluating the microleakage, restorations were cemented on human teeth and subjected to thermocycling. The teeth were vertically sectioned into two parts and microleakages were assessed as yes or no. Results: The highest and lowest fracture resistance values were found in TZI and LU groups, respectively ( p >0.05). The most frequent microleakage was observed in TZI and CR groups, and the least microleakage was seen in the VE group. Microleakage was frequently found in cervical surfaces and followed by occlusal, axial, and pulpal surfaces. Conclusion: Hybrid ceramics showed similar fracture resistance with the monolithic zirconia; besides, the lowest microleakage was observed for these ceramics. Hybrid ceramics may be a good alternative for inlay restorations. How to cite this article: Bankoğlu Güngör M, İnal CB, Hürbağ M, Toksoy B, Turhan Bal B, Karakoca Nemli S. Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays. Int Dent Res 2024;14(1):10-18. https://doi.org/10.5577/intdentres.324CAD-CAM, ceramic, inlays, aging, fracture resistance, microleakageMerve Bankoğlu Güngör, Ceyda Başak İnal, Meryem Hürbağ, Burcu Toksoy, Bilge Turhan Bal, Seçil Karakoca Nemli30.04.202410-18 -
The effect of cold drinks on the coloration of resin-containing restorative materials
Aim: Resin-containing restorative materials are widely used in the restoration of teeth. Our aim in this study is to examine the color change of beverages consumed cold on resin-containing restorative materials. Methodology: Samples were prepared using composite resins and resin-based CAD/CAM blocks. All prepared samples were kept in cold tea, cold coffee, coke, energy drink, and distilled water after polishing. The color values of the samples were measured with a spectrophotometer at the beginning, on the 1st, 7th and 30th days, and the color change values were calculated with the CIEDE2000 formula. Statistical analysis of color change values was performed using two-way analysis of variance (ANOVA) and Tukey multiple comparison tests (p<0.05). Results: While there was no statistically significant difference in the color changes of the resin-containing dental materials at the end of the 1st day (p>0.05), at the end of the 7th and 30th days, cold tea caused the statistically highest color change (p<0.05). There was no statistically significant difference between the color change values of cold coffee, coke and energy drink on the materials in all time periods (p>0.05). Composite resins showed more color change than resin-based CAD/CAM blocks (p<0.05). Conclusion: Cold tea causes the most discoloration on resin-based materials. While the resin-containing CAD/CAM blocks showed a color change under the AT value in all cold drinks, the composite resins showed a color change above the AT value in cold tea and coffee. How to cite this article: Altıparmak ET, Aybala Oktay E, Karaoğlanoğlu S, Aydın N, Ersöz B, Özarslantürk S. The effect of cold drinks on the coloration of resin-containing restorative materials. Int Dent Res 2022;12(1):14-20. https://doi.org/10.5577/intdentres.2022.vol12.no2.3 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.CAD/CAM, composite resin, color change, cold drinksElif Tuğba Altıparmak, Elif Aybala Oktay, Serpil Karaoğlanoğlu, Numan Aydın, Bilge Ersöz, Savaş Özarslantürk30.08.202214-20 -
The effect of different surface treatments on the color change of CAD/CAM restorative materials caused by coffee
Aim: This study aimed to evaluate the effect of different surface treatment protocols on the color stability of two CAD/CAM restorative materials, a hybrid ceramic (Vita Enamic) and a resin-based composite (Shofu Block HC), when exposed to filter coffee. Methodology: Sixty disk-shaped specimens (12 mm diameter, 1.5 mm thickness) were prepared from Vita Enamic and Shofu Block HC. The specimens were divided into six groups (n=10) based on the material and surface treatment: Mechanical Polishing Only, Glaze (Optiglaze) Only, and Mechanical Polishing + Glaze. After the surface treatments, baseline color measurements were performed using a spectrophotometer (Vita EasyShade V). The specimens were then immersed in a freshly prepared filter coffee solution, which was renewed daily for 15 days (simulating ~3 years of clinical exposure). Post-immersion color measurements were taken, and the color difference (ΔE) and lightness difference (ΔL) were calculated. Data were analyzed using two-way ANOVA and Tukey's HSD test (p < 0.05). Results: Two-way ANOVA revealed significant main effects of Material and Surface Treatment on both ΔE and ΔL (p < 0.001). A significant Material × Surface Treatment interaction was found for ΔL (p = 0.012) but not for ΔE (p = 0.207). Vita Enamic demonstrated significantly lower ΔE and higher ΔL values than Shofu Block HC, indicating better overall color stability and less darkening. For both materials, Mechanical Polishing Only resulted in significantly lower ΔE than glaze only or the combination group. For ΔL, Mechanical Polishing was superior for Vita Enamic, whereas Glaze Only yielded the most unfavorable results for Shofu Block HC. Conclusion: The color stability of CAD/CAM materials is significantly influenced by both material composition and surface treatment applied. Mechanical polishing provided the best color stability for both materials tested. Clinically, for restorations prone to coffee exposure, selecting a hybrid ceramic like Vita Enamic and finishing it with mechanical polishing is recommended to optimize long-term aesthetic performance.CAD-CAM, color stability, dental polishing, composite resin, coffee, surface propertiesMeryem Erdoğdu, Gözde Kaya Oğuz, Merve Karagöz, Ali Rıza Tunçdemir, Emine Begüm Büyükerkmen31.12.2025183-194 -
Examination of the Effect of Preheating Process on Microtensile Bond Strength in the Cementation of Indirect Restorations The Effect of Preheating Process on Microtensile Bond Strength
Aim: The aim of this study was to investigate the effect of preheating of inlay and onlay restorations prepared from composite materials and using a CAD/CAM device on microtensile bond strength in different structures. Methodology: In this study, 90 impacted human third molar teeth unaffected by the mouth environment were used. These teeth were divided into 3 groups. MOD inlay cavity preparation was performed on all samples according to the parameters specified. For the first group, restorations were prepared using a CAD/CAM device. For the second group, a fiber-reinforced composite (EverX Posterior, GC, Tokyo, Japan) was used on the bottom of the cavity to simulate dentin structure. Restoration was then completed using the laboratory composite system (Gradia, GC, Tokyo, Japan). For the third group, restorations were completed using the laboratory composite system (Gradia, GC, Tokyo, Japan) alone. Er,Cr:YSGG laser (Fotona Laser AT Fidelis Plus III, Slovenia) was administered on all prepared restorations for surface roughening. In the cementation of the restorations, resin cement was administered with and without preheating. The prepared samples were placed in a microtensile tester, and the sticks were broken off by setting the loading speed at 1 mm/min. The prepared samples were tested for microtensile bond strength (Microtensile Tester, Bisco, Schaumburg, IL, USA). The results obtained in Newtons were divided into the surface area and converted to MPa. The results were recorded as microtensile bond strength values. Results: There was no statistically significant difference between the groups in terms of the statistical evaluation of the microtensile bond strengths of the samples in which the adhesive cement was pre-heated (P) and not pre-heated (N) during the cementations (p>0.05). There was a statistically significant difference (p<0.05) in terms of the microtensile bond strength values between the groups in which the adhesive cement was pre-heated during the cementation of restorations. Conclusion: It was observed that exposure of the adhesive cement to preheating in the cementation of the EverX Posterior-based inlays adversely affects the bond strength. It was observed that the preheating process statistically significantly increased the bond strength in the inlays made using the Gradia composite. Preheating of the cement in the cementation of Cerasmart composite inlays produced using the CAD/CAM system did not affect the microtensile bond strength.Preheating, CAD/CAM, microtensile, fiber-reinforced compositeZuhal Görüş30.04.201815-21 -
Comparison of fracture strengths of post-core systems produced using traditional methods and CAD/CAM in endodontically treated teeth
Aim: The purpose of this study was to compare the fracture strengths of post systems used with CAD/CAM and traditional methods. Methodology: A total of 30 maxillary central teeth were used in the study. After the root lengths were standardized to be 10 mm, post sockets were prepared in the root canals. A total of 30 teeth were randomly divided into three groups (n=10). The post sockets were measured with silicone and sent to the laboratory. Samples were prepared after laboratory procedures. PEEK posts, fiber posts, and zirconia posts were cemented to the post sockets with resin cement. The test samples were kept at room temperature for 24 hours and then subjected to thermal cycling. After thermal cycling, force was applied to the test samples at a speed of 1 mm/min until the sample fractured. Statistical analysis was performed using one-way ANOVA (p<0.05) in SPSS. Results: The statistical analysis revealed a significant difference in mean fracture resistance among the groups (p<0.05). The highest mean fracture strength value in the tested groups was observed in the fiber post group (410.9 ± 106.2 N). The lowest mean was observed in the PEEK post group (215.1 ± 77.7). Conclusion: All groups of PEEK, glass fiber, and zirconium oxide post-cores showed sufficient fracture strength when compared with the mean of the maximum forces that can be applied to the teeth in the anterior region.PEEK, post-core, fracture strength, fiber post, zirconia post, CAD/CAMZuhal Görüş31.08.202579-84 -
Evaluation of the effects of different surface treatments on the bond strength of recent CAD-CAM hybrid ceramics
Aim: The aim of this study was to evaluate the effect of different surface treatments (control, hydrofluoric [HF] acid, sandblasting with Al 2 O 3 particles, tribochemical silica coating, and fiber laser) on the surface structure and shear bond strength of ceramics. Methodology: A total of 120 specimens were used for the evaluation of shear bond strength and 10 specimens for SEM. The ceramics were divided into two groups according to ceramic type and further divided into five subgroups according to surface treatments. SEM images were taken from each group after the surface treatments. Clearfil Ceramic Primer Plus silane was applied to all specimens. Panavia V5 adhesive resin cement was applied to the samples. The bond strength was measured through a shear test using the universal testing machine. A stereomicroscope was used to analyze the surfaces for the failure type. To determine statistical significance, one-way analysis of variance (ANOVA), Tamhane Multiple Comparison, Kruskal-Wallis H, Mann-Whitney U, and Bonferroni-corrected Mann-Whitney U tests were used. Results: The highest bond strengths were obtained for the groups treated with HF acid and sandblasting with Al 2 O 3 . The bonding strength values of Vita Enamic were higher than those of Lava Ultimate Conclusion: HF acid was the best treatment to increase the bond strength between ceramic and cement.Bond strength, CAD-CAM, hybrid ceramic, SEM analysis, surface treatmentsMerve Tokgöz Çetindağ, Ayşe Meşe, Begüm Evran31.12.2024105-113 -
Use of novel polyetheretherketone (PEEK) polymer in pediatric dentistry
The purpose of this study is to discuss the applications of PEEK in pediatric dentistry and the advantages of PEEK material in terms of periodontal health. In pediatric dentistry, there is a continuous search for biocompatible, esthetic, and durable materials to overcome the limitations of conventional options such as stainless steel and zirconia. Polyetheretherketone (PEEK), a high-performance semicrystalline polymer, has emerged as a novel alternative due to its superior mechanical properties, resistance to heat and chemicals, and an elastic modulus comparable to human bone. This review aims to evaluate the material characteristics of PEEK, its impact on periodontal health, and its clinical applications within pediatric dentistry. PEEK is amenable to digitalization and can be fabricated using CAD/CAM milling and 3D printing, ensuring precise fit and patient comfort. In pediatric orthodontics and space maintenance, PEEK serves as an esthetic, metal-free alternative, eliminating risks of nickel allergy while providing high strength and significantly reduced weight compared to traditional appliances. For restorative procedures, PEEK is utilized in crowns, endocrowns, and post-core systems. Its shock-absorbing capability allows for favorable stress distribution in dentin, reducing the risk of root fractures often associated with rigid materials like metal or glass fibers. Additionally, its low specific gravity and biocompatibility make it an effective material for obturators in treating cleft lip and palate defects. Regarding periodontal health, polished PEEK surfaces demonstrate low plaque affinity and acceptable surface roughness, supporting gingival health. PEEK offers distinct advantages in pediatric dentistry, particularly for patients requiring metal-free, lightweight, and shock-absorbing restorations. While it presents a promising alternative to traditional materials, achieving durable adhesion requires specific surface treatments, and further prospective clinical studies are warranted to validate its long-term performance.PEEK, pediatric dentistry, space maintainers, biocompatibility, CAD/CAM, periodontal health, dental applicationSemih Ercan Akgün, Şemsettin Yıldız, Samet Tekin31.08.202585-91 -
Endocrown restorations: A review
With advances in adhesive dentistry, endocrowns have emerged as a minimally invasive alternative to traditional methods for restoring endodontically treated teeth with severe tooth structure loss. Unlike traditional post applications, endocrowns are monoblock restorations anchored in the pulp chamber and the remaining coronal tooth tissue. The aim of this review is to evaluate the biomechanical properties, clinical performance, and key factors affecting the success of endocrown restorations in light of the current literature. While traditional post-core applications can weaken the tooth structure and increase the risk of root fractures, endocrowns offer advantages such as lower cost, shorter preparation time, and maximum preservation of tooth tissue. The literature reports that endocrowns exhibit excellent survival rates and adequate clinical performance in molar teeth. However, the higher non-axial (horizontal/lateral) forces and narrower bonding surfaces encountered in premolar and anterior teeth can increase the risk of restoration failure. One of the most important factors affecting clinical success is the preparation design. For optimal retention, the central retention cavity should have a minimum depth of 3 mm and a cervical margin width of at least 2 mm. Adding a ferrule, short axial walls, and a shoulder/chamfer finish line to the restoration design significantly increases fracture resistance. Furthermore, the application of immediate dentin sealing (IDS) protocols improves dentin bond strength and minimizes the risk of debonding. During fabrication, direct methods using composite resins can be used, or indirect methods using CAD/CAM technology with materials such as lithium disilicate, zirconia-reinforced ceramics, polymer-infiltrated ceramic networks (PICN), or PEEK can be preferred. Provided that appropriate cavity design, bonding surface, and material selection are ensured, endocrowns can perform similarly to, or better than, conventional treatments such as inlays/onlays, post-core restorations, or direct composite restorations. As a promising alternative for restoring heavily damaged, endodontically treated teeth, further long-term clinical studies are needed to confirm their overall suitability.Endocrown, endodontically treated teeth, Computer-Aided Design/Manufacturing, CAD/CAM, lithium disilicate, PEEK, dental materialsDersim Gökce, Emrah Ayna31.12.2025195-202 -
Comparison of light transmission of multilayered zirconia materials produced using different sintering methods
Aim: In multilayered zirconia blocks, the enamel layer consists of 5Y-TZP, whereas the transition and body layers consist of 3Y-TZP content. Zirconias, which have different compositions, can be sintered quickly and conventionally, but the effect of rapid sintering on light translucency is not fully known. The aim of this study was to investigate the effect of speed-sintering protocols on the light translucency of multilayered monolithic zirconia materials. Methodology: In this study, multilayered blocks underwent a speed sintering protocol: Katana Zirconia YML (Kuraray) and IPS e.max ZirCAD Prime (Ivoclar Vivadent). The samples were designed with a post-sintering diameter of 12 mm and thickness of 1 mm, and they were manufactured using a CAD/CAM milling machine (Onex Dental Coritec 350i). Samples obtained from the blocks were randomly divided into two groups and sintered in two different ways according to the sintering protocol (n=16). After sintering, L*, a*, b* values of all samples were measured with a spectrophotometer, and the measurements were recorded using black and white backgrounds. Translucency (TP) values were analyzed using a two-way analysis of variance (ANOVA) test to examine the effects of zirconia firing. Statistical analysis was performed using IBM SPSS. Results: The light translucency values of the ZirCAD Prime subgroup subjected to speed sintering were higher than those of the other groups. In the Katana YML group, no significant difference ( p =0.161) was observed between the subgroups that sintered rapidly and conventionally. Conclusion: The differences in light translucency values may be attributed to variations in the amount and thickness of 5Y-TZP zirconia in the enamel layer. The light translucency of the Katana Zirconia YML block was not affected by the sintering protocol, demonstrating that this block can be safely speed-sintered. How to cite this article: Güntekin N, Kızılırmak B, Tunçdemir AR. Comparison of light transmission of multilayered zirconia materials produced using different sintering methods. Int Dent Res. 2024;14(S1):55-59 https://doi.org/10.5577/indentres.551Monolithic zirconia, multilayered zirconia, speed-sintering, light translucency, 3Y-TZP, 5Y-TZPNeslihan Güntekin, Burcu Kızılırmak, Ali Rıza Tunçdemir31.12.202455-59 -
Retention in Orthodontics: A review
Skeletal and dental correction obtained by orthodontic treatment may tend to return to the pre-treatment state. This condition is defined as relapse. The retention phase applied after treatment is important to obtain stable results. Periodontium, soft tissue pressures, growth and occlusion are among the factors affecting stability. In the last decade, interest in retention procedures has increased and it has been found that retention regimes differ from country to country. Although retention affects nearly every patient, there is minimal agreement on the most appropriate approach to be taken in an individual case. The many variations of the retention procedure, the introduction of different materials for retention, or individual patient factors are among the reasons that lead to difficulties in selecting retention protocols. Basic retention protocol is provided with removable and fixed retention appliances. For removable retention, hawley, wraparound, vacuum formed retention appliance and positioners are used. For fixed retention, rigid steel retention wire bonded to terminal teeth or flexible retention wires bonded to all teeth between 3-3 can be preferred. NiTi retention wires produced with CAD / CAM technology are also among the current materials. While fixed retention appliances do not require patient cooperation, periodontal follow-up is recommended. Patient cooperation is needed for the use of removable retention appliances, but easy cleaning of removable appliances is an advantage. ‘Adjunct’ procedures may also be applied to the teeth or surrounding periodontium to assist the retention process. For example, it involves reshaping teeth such as interproximal reduction or circumferential supracrestal fiberotomy. In this review, information about retention is discussed in the light of current literature. How to cite this article: Seki Yurdakul M, Meriç P. Retention in Orthodontics: A review. Int Dent Res 2022;12(2):88-96. https://doi.org/10.5577/intdentres.2022.vol12.no2.7 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Orthodontic retention, relapse, stabilityMelis Seki Yurdakul, Pamir Meriç31.08.202288-96 -
Comparison of marginal adaptation and fracture strength of PEEK endocrown restorations fabricated using additive and subtractive methods
Aim: The aim of this in vitro study was to compare the marginal fit and fracture strength of endocrown restorations applied to maxillary canines, using different manufacturing methods. Methodology: An extracted upper canine tooth was prepared for endocrown placement. Three methods were used to create the endocrowns: Fused Deposition Modeling (FDM) 3D printing with Essentium Polyetheretherketone (PEEK) filament, CAD/CAM milling with Juvara PEEK disk, and SLS 3D printing with Cr-Co metal (N=10). Additionally, 30 identical canine tooth replicas were produced using an Asiga 3D printer with a model resin, and the crown restorations were cemented with a resin luting cement. Fracture strengths were tested, and marginal fits were evaluated using Geomagic Control X software. Statistical analysis was performed, and Weibull analysis was used to assess fracture strength values. Results: The laser-sintered endocrowns exhibited higher fracture strength (1351 N) compared to PEEK FDM (735.341 N) and milled PEEK (826.733 N) endocrowns. The highest Weibull modulus was found for milled PEEK (3.978), while the lowest was for the Cr-Co laser-sintered material (2.912). A significant difference in marginal fit was observed on the palatal surface of the PEEK FDM group compared to the other two groups (p=0.048). However, no significant differences were found on the mesial, distal, or buccal surfaces. Conclusion: The findings indicate that PEEK endocrowns produced by FDM and milling offer clinically acceptable fracture strength and marginal fit, with PEEK being closer to the dentin elastic modulus. The significantly higher Weibull modulus of PEEK endocrowns produced by the FDM Printer and milling enables us to make more accurate intraoral fracture predictions.Endocrown, PEEK, FDM, fracture strength, milling, Weibull analysisAyşe Rençber Kızılkaya, Oğuzhan Kaya, Aybüke Kara, Eyyüp Altıntaş, Samet Tekin31.08.202545-52 -
The effect of ytterbium-doped fiber laser on titanium fused to ceramic
Aim: The aim of our study is to compare the application of fiber lasers with aluminum oxide sandblasting and CoJet, which is one of the other surface roughening methods used for the first time in this study. Investigating the effect of titanium–porcelain bond strength is another aim of this study. Methodology: In total, 96 samples of titanium discs (6 mm in diameter and 3 mm in height) were prepared in a CAD/CAM device. Samples were divided into six groups (n: 10), including the control group, according to the applied surface treatments: one-way (horizontal) scanning with a Yb fiber laser, two-way (horizontal-vertical) scanning with a Yb fiber laser, three-way (horizontal–vertical–hypotenuse) scanning with a Yb fiber laser, CoJet, sandblasting, and the control group. After using the different surface treatments on the titanium discs, scanning electron microscope (SEM) imaging, a wettability test, and a profilometer test were applied to the samples in each group. After the surface treatments were applied to the titanium discs, including those in the control group, low heat porcelain (VITA Titanium Porcelain), which was 4 mm in diameter and 3 mm in height, was applied according to the manufacturer's instructions. Afterwards, porcelain samples prepared with titanium inlays were placed in acrylic blocks and kept in 37°C (±1°C) distilled water for 24 hours. Shear tests were applied to the samples embedded in prepared acrylic blocks, and the results were evaluated. Results: In the statistical evaluation of the obtained data, one-way analysis of variance (one-way ANOVA) was used to compare the statistical differences of the mean values of the bond strength between titanium and porcelain. In our study, Tukey’s HSD and Dunnett’s multiple comparison statistical tests were used to determine the differences among the groups. Conclusion: According to the results of our study, the highest average bond strength values were obtained from sandblasting and three-way fiber laser roughness. As a result, no statistically significant difference was found among the groups. Although Yb fiber laser application was not found to have a statistically significant effect on titanium porcelain bond strength, this method could be useful for titanium porcelain bonding. ain bonding. How to cite this article: Tepe İH, Nigiz R, Seyfioğlu Polat Z, Mutluay Ünal S. The effect of ytterbium-doped fiber laser on titanium fused to ceramic. Int Dent Res 2021;11(Suppl.1):128-36. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.20 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.titanium, ytterbium-doped fiber laser, bond strength, surface roughening, porcelainİbrahim Halil Tepe, Remzi Nigiz, Zelal Seyfioğlu Polat, Server Mutluay Ünal30.09.2021128-136 -
Shade selection for IPS e.max lithium disilicate crowns on maxillary central incisors: A case report and literature review
Shade selection is a critical step in the esthetic rehabilitation of anterior teeth, because the final appearance of an all-ceramic restoration depends on the selected shade, the ceramic material and its thickness, the color of the underlying tooth structure, and the luting cement. This case report and literature review describes the restoration of both maxillary central incisors with IPS e.max lithium disilicate crowns. A 32-year-old woman with a history of dental trauma and repeated composite restorations was dissatisfied with the appearance of her maxillary central incisors, which were lingually inclined, contained extensive composite resin restorations, and showed morphological irregularities. A conservative plan limited to these two teeth was adopted, and IPS e.max crowns were preferred over laminate veneers because of the volume of the existing restorations. After minimal buccal reduction with a knife-edge finish line, shade was selected with the Vita 3D-Master guide and clinical photographs, and the prepared dentin shade (1M2) was also recorded. The first crowns, fabricated in shade 2M1 and cemented with a translucent light-cured resin cement, appeared darker than the neighboring teeth. One week later, they were replaced with higher-value 1M1 crowns, which were cemented with a bleach-shade cement using the same bonding protocol. At the 6-month follow-up, the restorations blended with the neighboring dentition in color, form, and surface texture. The reviewed literature indicates that visual shade selection is subjective and is best combined with instrumental methods; that value is the most important dimension of color perception; and that ceramic thickness, substrate color, and cement shade can cause perceptible color differences in glass-ceramic restorations. Within the limitations of a single case, natural esthetic results can be achieved even when only two anterior teeth are restored, provided that visual and digital methods are combined, the color–material–cement interaction is managed, and clinician and technician communicate closely.Ceramics, color perception, crowns, dental esthetics, prosthesis coloring, resin cementsEkin Gökmen Akmansu, Nihal Özcan03.11.2026e260671 -
Effects of accelerated aging cycles on resin cement-glass ceramic bond strength
Aim: A successful restoration is the result of the proper adhesion between dental tissue, cement and restoration material. The long-term durability of this bond is mandatory for clinical success. The aim of the present study is to investigate the influences of three different thermal cycle applications on resin cement-glass ceramic shear bond strength. Methodology: In the present study, a single CAD/CAM glass ceramic block and five different resin cements (Panavia V5, RelyX U200, G-CEM LinkForce, RelyX Veneer,and Variolink Esthetic) were used. A total of 240 sections 2 mm in thickness were obtained under water cooling in a precision cutting machine with the aid of a diamond saw. Cementation of glass ceramic samples was conducted in accordance with the instructions of the manufacturer, and the cemented samples were incubated at 37 °C for 24 hours. Afterwards, samples were randomly divided into four groups according to thermal cycle: control group, 1750, 3500 and 7000 cycles (n = 12). Following aging procedures, the samples were tested for shear bond. Statistical analyses were done by using the IBM SPSS 20.0 program. While the ANOVA test was used for intra-group statistical analyses, LSD multi-comparison analysis was used for detection of the inter-group differences. Statistical significance was set at p < 0.05. Results: Although an overall reduction was seen in shear bond of all cement groups following thermal cycle applications, this reduction was found to be statistically significant for Panavia V5, RelyX Veneer and Variolink Esthetic (p<0.05). Following 1750 cycles of thermal cycle application, Panavia V5 and G-Cem LinkForce with dual-cure property showed higher shear bond strength than RelyX Veneer and Variolink Esthetic with light-cure structure (p<0.05). Conclusion: The reduction in bond strength following the thermal cycle procedure is associated with water absorption in the resin cement-glass ceramic interface. So resin cement preferred for cementation of restorations is among the key parameters for clinical success. How to cite this article: Eskitaşçıoğlu M, Bozbay R, Ünalan Değirmenci B. Effects of accelerated aging cycles on resin cement-glass ceramic bond strength. Int Dent Res 2021;11(2):121-8. https://doi.org/10.5577/intdentres.2021.vol11.no2.10 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.cementation, ceramics, resin cementsMurat Eskitaşçıoğlu, Rabia Bozbay, Beyza Ünalan Değirmenci31.08.2021121-128 -
Evaluation of surface roughness of composites obtained by additive and subtractive manufacturing methods after sandblasting
Aim: The aim of this study was to observe the change in the surface roughness of composite samples produced by different production methods after sandblasting with aluminum oxide particles and to evaluate the effect of this on the composite material. Methodology: The study tested three subtractive method composites (GC Cerasmart [GC], Vita Enamic [VE] and Grandio Voco [GV]) and one additive method composite (3D Formlabs [3D]) were used. Each subtractive composite had 11 samples (14 x 14 x 2 mm) prepared with an Isomet low-speed saw, whereas the additive composite had 11 specimens produced using an SLA-based 3D printer (Form 2; Formlabs Inc). For roughness measurements and sandblasting, the samples were marked with an adhesive circular paper. Surface roughness was measured using a MarSurf SF1 profilometer, with three readings per sample. Sandblasting with aluminum oxide particles (50 µm) was performed using an Aquacare twin in-mouth sandblaster, and surface roughness measurements were repeated. Statistical analysis was performed using one-way analysis of variance (ANOVA) via SPSS 26, with significance set at p =0.05. Results: Among the composite samples, Vita Enamic (VE) had the highest average roughness value, and 3D Formlabs (3D) had the lowest. VE had a mean roughness value of 0.4575 µm, GC had a mean roughness value of 0.4627 µm, GV had a mean roughness value of 0.665 µm and D had a mean roughness value of 0.4575 µm. All groups were compared pairwise with each other. A significant difference was found between the GV-D, VE-D, GC-GV, GC-VE, and GC-D group pairings ( p <0.05). There was no significant difference between the GV-VE and GC-D group pairings ( p >0.05). Conclusion: Sandblasting with aluminum oxide was observed to increase the roughness of the materials, and the roughness varied depending on the nature of the material. Further studies are required to investigate the effects of roughness on the bonding. How to cite this article: Güntekin N, Alkurt S, Çiftçi A, Gönder HY, Büyükerkmen EB. Evaluation of surface roughness of composites obtained by additive and subtractive manufacturing methods after sandblasting. Int Dent Res. 2024;14(S1):60-64 https://doi.org/10.5577/indentres.559CAD-CAM, composite, surface roughness, wear, sandblasting, 3D printingNeslihan Güntekin, Sinem Alkurt, Aslı Çiftçi, Hakan Yasin Gönder, Emine Begüm Büyükerkmen31.12.202460-64
1 - 16 of 16 items


















Open Access articles are distributed under the terms of the