Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Graphical abstract: Shade selection for anterior IPS e.max crowns

    Shade selection for IPS e.max lithium disilicate crowns on maxillary central incisors: A case report and literature review

    Shade selection is a critical step in the esthetic rehabilitation of anterior teeth, because the final appearance of an all-ceramic restoration depends on the selected shade, the ceramic material and its thickness, the color of the underlying tooth structure, and the luting cement. This case report and literature review describes the restoration of both maxillary central incisors with IPS e.max lithium disilicate crowns. A 32-year-old woman with a history of dental trauma and repeated composite restorations was dissatisfied with the appearance of her maxillary central incisors, which were lingually inclined, contained extensive composite resin restorations, and showed morphological irregularities. A conservative plan limited to these two teeth was adopted, and IPS e.max crowns were preferred over laminate veneers because of the volume of the existing restorations. After minimal buccal reduction with a knife-edge finish line, shade was selected with the Vita 3D-Master guide and clinical photographs, and the prepared dentin shade (1M2) was also recorded. The first crowns, fabricated in shade 2M1 and cemented with a translucent light-cured resin cement, appeared darker than the neighboring teeth. One week later, they were replaced with higher-value 1M1 crowns, which were cemented with a bleach-shade cement using the same bonding protocol. At the 6-month follow-up, the restorations blended with the neighboring dentition in color, form, and surface texture. The reviewed literature indicates that visual shade selection is subjective and is best combined with instrumental methods; that value is the most important dimension of color perception; and that ceramic thickness, substrate color, and cement shade can cause perceptible color differences in glass-ceramic restorations. Within the limitations of a single case, natural esthetic results can be achieved even when only two anterior teeth are restored, provided that visual and digital methods are combined, the color–material–cement interaction is managed, and clinician and technician communicate closely.
    Ceramics, color perception, crowns, dental esthetics, prosthesis coloring, resin cements
    Ekin Gökmen Akmansu, Nihal Özcan
    03.11.2026
    e260671
    Abstract Views: 124 Download: 118 DOI 10.5577/intdentres.671
  • Investigation of the effect of different application techniques on microhardness in bulk-fill composite resins

    Aim: The aim of this study was to investigate the effect of different application techniques on microhardness in one universal resin material and three different bulk-fill composite resin materials. Materials and Methods: In this study, one universal composite resin (Universal Restorative 200 [U], 3M-ESPE, USA) and three different bulk-fill composite resins (Filtek-One Bulk-Fill Restorative [F]; 3M-ESPE, USA: Tetric Evo-Ceram Bulk-Fill [E]; and Ivoclar-Vivadent, Liechtenstein; Tetric N-Ceram Bulk-Fill [N], Ivoclar-Vivadent, Liechtenstein) materials were used. A total of 60 disk-shaped samples, including 20 samples from each bulk-fill composite resin group, were prepared. The polymerization of the bulk-fill composite resins in one group was completed using a 2 mm (40 sec) + 2 mm (40 sec) incremental technique, and in the other group, it was completed using a 4 mm bulk technique (40 sec). The U composite resin (control group) polymerization was completed using a 2 mm + 2 mm (40 sec) incremental technique (n = 10). The Vickers microhardness (VHN) values ​​of the samples were calculated. The data were analyzed with Kruskal–Wallis and Mann–Whitney U tests (p < 0.05). Results: Higher VHN values ​​were found in the U composite resin compared to those in the bulk-fill composite resins (p < 0.05). In the bulk technique, a lower VHN value ​​was observed in the N bulk-fill composite resin than in the control group (p < 0.05), while there was no difference between the N and E composite resin groups (p > 0.05). A lower N bulk-fill composite resin was observed in the groups in which the incremental technique was applied than in the control group (p < 0.05). When the techniques applied to the bulk-fill composite resins were evaluated within themselves, higher VHN values ​​were observed in the E composite resin in the group in which the incremental technique was applied but not in the group in which the bulk was applied. Conclusion: It was observed that the content differences of composite resins were effective at different VHN values. The U composite resin (control) group showed higher VHN values than all the bulk-fill composite groups.   How to cite this article: Fidan M, Gönder HY. Investigation of the effect of different application techniques on microhardness in bulk-fill composite resins. Int Dent Res 2021;11(Suppl.1):32-7. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.6   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    bulk-fill composite resin, bulk technique, incremental technique, microhardness
    Muhammet Fidan, Hakan Yasin Gönder
    30.09.2021
    32-37
    Abstract Views: 1582 Download: 724 DOI 10.5577/intdentres.2021.vol11.suppl1.6
  • Shear bond strength of composite to demineralized enamel conditioned with resin infiltration

    Aim: The aim of this in vitro study was to evaluate the influence of resin infiltration on bond-strength of composite resin to demineralized enamel. Methodology: Thirty bovine incisors were used in this study. Buccal enamel surfaces of bovine incisors were wet polished and then were divided into three groups: sound enamel; demineralized enamel; demineralized enamel infiltrated with a low-viscosity resin (ICON, DMG, Hamburg, Germany). After acid-etching with 37% phosphoric acid for 20 seconds, a two-step, total-etch adhesive (Single Bond 2, 3M ESPE, St. Paul, MN, USA) was applied using a microbrush for 20 seconds, followed by gentle air-drying for 5 seconds. The adhesive was light-cured for 10 seconds. Following the adhesive application, flowable composite resin (Filtek Supreme Flowable, 3M ESPE, St. Paul, MN, USA) was gently placed into a microtubule and was photopolymerized using an LED curing unit (Elipar Deep Cure; 3M ESPE, St. Paul, MN, USA). The microshear bond strength (µSBS) tests were performed using a microshear testing machine at a cross-head speed of 0.5 mm/min. One-way ANOVA and Bonferroni tests were used to analyze the data (5%). Results: Significant differences were found according to the ANOVA ( p < 0.05). Pair-wise comparison results of µSBS (mean ± SD) were: sound enamel (25.16 ± 2.3); demineralized enamel (17.93 ± 2.1); demineralized enamel infiltrated with a low-viscosity resin (28.51 ± 3.76). Conclusion: Resin infiltration applied to demineralized enamel before composite application increased the bond strength. No difference was found in the bond strength values obtained for sound enamel and resin infiltrated enamel.   How to cite this article: Durukan SM, Gümüştaş B, Şişmanoğlu S. Shear bond strength of composite to demineralized enamel conditioned with resin infiltration. Int Dent Res 2022;12(Suppl.1):114-19. https://doi.org/10.5577/intdentres.441   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Enamel, bond strength, resin infiltration, demineralization, remineralization, composite resin
    Sebahat Melike Durukan, Burak Gümüştaş, Soner Şişmanoğlu
    31.12.2022
    114-119
    Abstract Views: 1465 Download: 625 DOI 10.5577/intdentres.441
  • Bonding performance of different types of expired and unexpired composite resin cements

    Aim: The aim of this study was to compare the bond strength of three expired and unexpired composite resin cements used between tooth and ceramic surfaces. Methodology: In this study, the dentin surfaces of 60 non-carious human teeth and ceramic specimens were bonded with three different resin cements. The resin cements used to bond the teeth and ceramic blocks were divided into two subgroups by expiration date (Group 1a. Variolink II-unexpired, 1b. Variolink II-expired 12 months prior. Group 2a. RelyX Unicem-unexpired, 2b. RelyX Unicem-expired 12 months prior. Group 3a. Panavia F 2.0-unexpired, 3b. Panavia F 2.0-expired 12 months prior). The samples were thermally cycled for 3,000 cycles in a temperature range of 5°C–55°C. The shear bonding test was performed using a universal tester. The force required for ceramic debonding was recorded. Surface fracture analysis was performed using a stereomicroscope. Mann–Whitney U test was used to compare the bond strength of resin cements with different expiration dates. P -value < 0.05 was considered statistically significant. Results: The difference in bond strength between the unexpired resin and the resin that had expired 12 months before the analysis was found not to be statistically significant in the Variolink II and Panavia pairs but significant in the RelyX resin cement pair. Conclusion: The self-adhesive resin cements that expired one year earlier showed lower bond strength than their unexpired counterparts; however, the use of expired total-etch and self-etch systems did not significantly affect bond strength.   How to cite this article: Karagözoğlu İ, Aksel L. Bonding performance of different types of expired and unexpired composite resin cements. Int Dent Res 2023;13(2):54-59. https://doi.org/10.5577/idr.2023.vol13.no2.2   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Composite resin cements, expiration date, bond strength, storage conditions
    İrem Karagözoğlu, Leyla Aksel
    31.08.2023
    54-59
    Abstract Views: 2069 Download: 1548 DOI 10.5577/idr.2023.vol13.no2.2
  • The effect of immediate dentin sealing on fracture resistance and failure modes of resin composite onlay restorations

    Aim: This study aimed to investigate the fracture resistance, failure modes, and reparability of molars restored with laboratory-processed resin composite (Ceramage, SHOFU Inc., Kyoto, Japan) onlays above or below the cemento-enamel junction (CEJ) in the presence or absence of immediate dentin sealing (IDS). Methodology: Forty extracted sound human molars were selected and divided into four groups: 1) Below CEJ with IDS, 2) Below CEJ without IDS, 3) Above CEJ with IDS, and 4) Above CEJ without IDS. Standardized mesio-occlusal (MO) onlay preparations were made with the reduction of mesio-buccal and mesio-palatinal cusps. Butt-joint preparation was used in the proximal box area extending 1 mm below the CEJ (Groups 1 and 2) or 1 mm above the CEJ (Groups 3 and 4). In Groups 1 and 3, IDS was applied immediately after tooth preparation. After cementation (Variolink N, Ivoclar Vivadent AG, Schaan, Liechtenstein), the specimens were thermally aged (20000 cycles, 5–55 ºC) and then subjected to load to failure (1 mm/min). The failure types and reparability of the onlays were recorded, and the data were analyzed using two-way ANOVA and Fisher’s exact tests. Results: The restorations in Group 4 showed the highest mean fracture strength compared to Group 1 ( p =0.038), Group 2 ( p =0.008), and Group 3 ( p =0.019). The interaction between the level of proximal extension and the presence of IDS did not influence fracture mode or reparability ( p >0.05). Conclusion: No difference in the fracture strength of resin composite onlays below CEJ with or without IDS was found; however, not using IDS for resin composite onlays above CEJ appears to be preferable.   How to cite this article: Gözetici Çil B, Köymen SS, Ünal S, Dönmez N. The effect of immediate dentin sealing on fracture resistance and failure modes of resin composite onlay restorations. Int Dent Res 2024;14(1):27-33. https://doi.org/10.5577/intdentres.510  
    Onlays, fracture strength, immediate dentin sealing, composite resin
    Burcu Gözetici Çil, Safiye Selin Köymen, Serpil Ünal, Nazmiye Dönmez
    30.04.2024
    27-33
    Abstract Views: 1610 Download: 558 DOI 10.5577/intdentres.510
  • Investigation of microhardness, surface roughness, and color change of preheated composite resins

    Aim: Applying heat is a method currently used to enhance the depth of polymerization in composite resin. This study aimed to evaluate the effects of heat treatment on resin hardness, color change, and surface roughness. Methodology: In this study, 64 samples (8 mm 2 × 2 mm 2 ) were produced (3M Filtek Universal, G-aenial A’CHORD, Neo Spectra and Clearfil Majesty ES-2) using a Teflon mold (n = 8). Half of the samples were preheated to 50 o C, while the other half were polymerized at room temperature. Initial color measurements were performed using a spectrophotometer, the surface roughness was assessed with a profilometer, and the microhardness was determined using a Vickers microhardness device. Subsequently, all samples were immersed in a coffee solution at 37 o C. The color changes were documented by the seventh day. The changes in color, roughness, and hardness of the materials were examined by the thirtieth day. Results: The groups that received heat treatment exhibited higher hardness values. The unheated G-aenial A’CHORD composite resin demonstrated the most significant color change by the end of the thirtieth day, while heated and unheated Clearfil Majesty ES-2 composite samples exhibited the least color change. By the end of the thirtieth day, the surface roughness of all samples increased significantly from the baseline, with the 3M Filtek Universal samples, both heated and unheated, showing the highest surface roughness. Conclusion: According to the results of this study, heat treatment of composite resins before polymerization reduces discoloration and improves hardness. Therefore, it is recommended to heat composite resins before application.   How to cite this article: Çekmez MB, Karaoğlanoğlu S, Aybala Oktay E, Aydın N, Ersöz B. Investigation of microhardness, surface roughness, and color change of preheated composite resins. Int Dent Res 2024;14(1):42-49. https://doi.org/10.5577/intdentres.523    
    Composite resin, microhardness, surface roughness, color change, preheating, polymerization
    Malhun Begüm Çekmez, Serpil Karaoğlanoğlu, Elif Aybala Oktay, Numan Aydın, Bilge Ersöz
    30.04.2024
    42-49
    Abstract Views: 2062 Download: 598 DOI 10.5577/intdentres.523
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex

    Aim: Secondary caries is an important problem in dental composite restoration, and nanoparticles are commonly added to the structures of resin composites to improve their antimicrobial properties. The aim of this study is to evaluate the mechanical properties of composite materials containing bioactive glass (BAG) and an experimental nano zinc-silica (NZS) complex. Methodology: An experimental resin composite containing 70 wt% filler was produced and used as a control sample. This experimental resin composite was then modified by adding different amounts of BAG (10%), NZS (10%), and both BAG and NZS (10% + 10%). NZS was synthesized in situ by milling zinc and silica to nanoscale level. Compressive strength and flexural strength were investigated using a universal testing machine. Data were analyzed using one-way ANOVA and the Tukey post-hoc test. Results: There were no statistically significant differences in compressive strength caused by the filler amount, but statistically significant changes were found in flexural strength. Although the addition of antimicrobial agents to resin composites reduces their physical properties, this is not a clinically unacceptable limit. Conclusion: NZS exhibits better mechanical properties than does BAG, but both materials can be used safely in restorative materials.   How to cite this article: Tunçdemir MT, Demirel MG. Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex. Int Dent Res 2021;11(Suppl.1):137-42.  https://doi.org/10.5577/intdentres.2021.vol11.suppl1.21   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    bioactive glass, experimental composites, mechanical properties, resin composites, nano zinc-silica
    Mehmet Gökberkkaan Demirel, Makbule Tuğba Tunçdemir
    30.09.2021
    137-142
    Abstract Views: 11127 Download: 599 DOI 10.5577/intdentres.2021.vol11.suppl1.21
  • Two-year clinical evaluation of Class I composite resin restorations using three adhesive systems: A double-blind randomized clinical trial

    Aim: The purpose of this randomized split-mouth clinical study was to assess the effect of three adhesive systems on the 2-year clinical success of Class I composite resin restorations. Methodology: In the treatment of the Class I carious lesions of 20 participants aged 18–24 years with at least three similar carious lesions, three adhesives—Clearfil SE Bond (CSE; Kuraray, Osaka, Japan), Single Bond 2 (SB2; 3M ESPE, St. Paul, MN, USA), and Tri-S Bond (TSB; Kuraray, Osaka, Japan)—and a Filtek Z550 nanohybrid composite resin (3M ESPE, St. Paul, MN, USA) were cured. The baseline and 2-year results of the restorations were assessed according to the World Dental Federation (FDI) and the United States Public Health Service (USPHS) criteria. The chi-square test was used to analyze the data obtained. Results: There was no loss of restoration in any group at 2 years. No significant differences were observed in any criteria (marginal staining, fracture retention, secondary caries, and postoperative sensitivity) evaluated except marginal adaptation, in accordance with FDI and USPHS criteria ( p > 0.05). At 2 years, SB2 showed the best marginal adaptation, followed by CSE and TBS. There was a statistically significant difference between SB2 and TSB ( p ˂ 0.05). Conclusion: All three adhesive systems can be used successfully in the restoration of Class I carious lesions.     How to cite this article: Çakır Kılınç NN, Demirbuğa S. Two-year clinical evaluation of Class I composite resin restorations using three adhesive systems: A double-blind randomized clinical trial. Int Dent Res 2023;13(2):67-74. https://doi.org/10.5577/idr.2023.vol13.no2.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Adhesive system, clinical follow-up, composite resin, Class I restoration, USPHS, FDI
    Nazire Nurdan Çakır, Sezer Demirbuğa
    31.08.2023
    67-74
    Abstract Views: 2266 Download: 599 DOI 10.5577/idr.2023.vol13.no2.4
  • Comparative evaluation of the effects of sodium ascorbate, alcohol, and calcium hydroxide on the bond strength of composite resin to dentin in non-vital teeth bleaching

    Aim: The aim of this in vitro study was to investigate the effects of sodium ascorbate, alcohol, and calcium hydroxide as a buffering agent on composite resin-dentin bond strength of non-vital teeth bleaching. Methodology: For our study, we used 80 human upper central teeth. An endodontic access cavity was opened on the palatal surface of the teeth. The root portion of the teeth was removed 2-3 mm below the enamel-cementum junction. Sodium perborate was used for the nonvital bleaching of all teeth. Following bleaching, four experimental groups were created: sodium ascorbate, alcohol, calcium hydroxide, and a control group. 1x1 mm specimens were obtained using a precision cutting device in all four experimental groups restored with bond and composite resin. The specimens were then subjected to tension tests in a microtensile device, and the resulting data were compared in terms of composite resin-dentin bond strength. Results: The study data were analyzed using the Kruskal-Wallis H test due to non-normal distributions of variables to compare groups. If the Kruskal-Wallis test indicated significant differences, a post-hoc multiple-comparison test was used to identify which groups differed. The Shapiro-Wilk test was used to determine whether the variables followed a normal distribution, based on the number of units. A statistically significant difference in binding strength was found between the study groups ( p <0.05). Specifically, the binding strength value of the sodium ascorbate group was significantly higher than that of the calcium hydroxide and control groups ( p <0.05). However, no statistically significant difference was observed between the other groups. Conclusion: After non-vital bleaching, sodium ascorbate can be used to improve the bond strength between composite resin and dentin. Further studies are needed to support the effect of alcohol and calcium hydroxide applications on bond strength.
    non-vital bleaching, bond strength, sodium perborate, sodium ascorbate, alcohol, calcium hydroxide
    Beyhan Başkan, Özkan Adıgüzel
    30.04.2025
    38-44
    Abstract Views: 1534 Download: 429 DOI 10.5577/intdentres.536
  • Investigation of the coloring effects of different ground-based coffee types on composite resin materials

    Aim: The aim of this study is to investigate the effect of different ground-based coffee types on the color change of nanohybrid and bulk-fill composites. Methodology: A total of 80 disk-shaped samples were made using Teflon molds (5 mm in diameter and 8 mm thick) and two types of A2 resin with nanohybrid (Tetric N Ceram Ivoclar Vivadent, Schaan, Liechtenstein) and bulk-fill (Filtek Bulk-Fill, 3M ESPE, St. Paul, MN, USA) structures. All samples were finished and polished with four-stage (thick, medium, fine, and superfine) polishing disks (Sof-lex, 3M ESPE, St. Paul, MN, USA) and kept at 37°C for 24 hours. Color measurements of the samples were performed using a spectrophotometer (Vita Easy Shade, Vita ZahnFabrik, Bad Sackingen, Germany) and were divided into subgroups: the control group, filter coffee, Turkish coffee, espresso, and Mırra (n = 8). Distilled water was used as a control. Prepared coffees were added to the microcentrifuge tubes and refreshed daily during the 14-day exposure period. ΔE values were calculated for each material. Statistical analyses were performed using one-way variance analysis and Tukey multiple comparisons ( p = 0.05). Results: There was no significant color change for either the nano-fill or bulk-fill composite groups in the control group samples (p>0.05). Filter coffee was found to be the most effective colorant coffee type for both composites ( p < 0.05). Among the coffee types, Mırra caused the least coloration for both composites. Conclusion: The consumption of two or more cups of coffee per day, especially filter coffee, can cause color changes in both conventional and bulk-fill composites, and it should be considered an important factor in aesthetic problems with dental restorations.   How to cite this article: Erdoğdu M, Tunçdemir MT, Güntekin N. Investigation of the coloring effects of different ground-based coffee types on composite resin materials. Int Dent Res 2022;12(Suppl.1):16-21. https://doi.org/10.5577/intdentres.448   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Bulk-fill composite, nanohybrid composite, coffee, composite resin, colorant effect, staining
    Meryem Erdoğdu, Makbule Tuğba Tunçdemir, Neslihan Güntekin
    31.12.2022
    16-21
    Abstract Views: 1620 Download: 699 DOI 10.5577/intdentres.448
  • Investigation of nanohardness values of dual-cure, bulk-fill composite resins at different time intervals

    Aim: The aim of this study was to evaluate the surface hardness of dual-cure, bulk-fill composite resins at different depths and time intervals using nanoindentation. Methodology: In the study, a comparison was conducted of the nanohardness values of Fill-Up, HyperFIL, and Cention N dual-cure, bulk-fill composite resins in the experimental group and Reveal HD, a light-cured, bulk-fill composite, in the control group. The dual-cure, bulk-fill composites used in the experimental group were divided into two subgroups. The first group was polymerized with an LED light source, and the second group was chemically polymerized in line with the manufacturer's instructions. The dual-cure composite resins were prepared in two different depths, 5 mm and 10 mm. In the control group, specimens with a depth of 5 mm were prepared, and their polymerization was provided by an LED light source. The nanohardness values of the lower and upper surfaces of the samples were measured using the Hysitron TI 950 Triboindenter 24 hrs and 7 days after polymerization. Results: Following statistical evaluations, no statistically significant difference was found between the nanohardness values measured 24 hrs and 7 days after light or chemical polymerization of the dual-cured, bulk-fill composite resins. It was observed that light polymerization of HyperFIL and Fill-Up dual-cure, bulk-fill composite resins had no effect on nanohardness values. When Cention N dual-cure, bulk-fill composite resin was polymerized with a light source, higher values of nanohardness were obtained. Conclusion: It was determined that the investigated dual-cure, bulk-fill composites reached their final hardness after 24 hrs. In all groups, it was observed that the highest nanohardness values belonged to Cention N for both polymerization methods.   How to cite this article: Bolgül B, Özdemir E. Investigation of nanohardness values of dual cure bulk-fill composite resins at different time intervals. Int Dent Res 2021;11(Suppl.1):19-25. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    dual-cure, bulk-fill, composite resin, nanohardness, pediatric dentistry
    Eda Özdemir, Behiye Bolgül
    30.09.2021
    19-25
    Abstract Views: 2925 Download: 669 DOI 10.5577/intdentres.2021.vol11.suppl1.4
  • Unilateral peg-shaped mandibular central incisor and direct composite resin treatment: A case report

    Aim: This case report describes the restorative treatment process of a non-syndromic unilateral peg-shaped left mandibular central incisor. Case presentation: A 23-year-old female patient was admitted for aesthetic concerns related to the appearance of the anterior mandible and a peg-shaped incisor. The color selection was done on clean, hydrated teeth. The teeth were roughened with a minimal red belt bur, a 37% phosphoric acid gel was applied to the enamel for 30 seconds, and the teeth were washed with water for 30 seconds to remove the acid agent. Following the application of a universal adhesive to the surface according to the manufacturer’s instructions, the palatal and proximal walls were formed using a mylar strip and an A2B-colored resin composite. Then, polymerization of the restoration was completed using an incremental layering technique. After the removal of any excess restoration, low-speed finishing and polishing were done using aluminum oxide and flexible rubber polishing disks containing diamond particles. After the resin application, the treatment was completed. Conclusion: To achieve optimal results in the treatment of patients, restorative treatment can be recommended, considering the position and condition of the tooth. When choosing the most appropriate treatment for a patient, the advantages and limitations of each technique should be carefully explained, and the most conservative treatment should be recommended.   How to cite this article: Fidan M. Unilateral peg-shaped mandibular central incisor and direct composite resin treatment: A case report. Int Dent Res 2023;13(1):44-47. https://doi.org/10.5577/idr.2023.vol13.no1.7   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Dental anomalies, microdontia, peg-shaped teeth, resin composite, morphological disorders
    Muhammet Fidan
    30.04.2023
    44-47
    Abstract Views: 2516 Download: 636 DOI 10.5577/idr.2023.vol13.no1.7
  • The effect of different herbal teas on the color stability of nanohybrid and bulk-fill composites

    Aim: The aim of this study is to investigate the effects of green tea and rosehip tea, on the color stability of nanohybrid and bulk-fill composite resins. Methodology: A total of 60 disc-shaped samples were made from two types of A2 resin with nanohybrid (Tetric N Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) and bulk-fill (Filtek Bulk-Fill, 3M ESPE, MN, USA) structure with the help of 10 mm diameter and 2 mm thick Teflon molds in this study. All samples were finished and polished with 4-stage (thick, medium, fine, superfine) polishing discs (Sof-lex, 3M ESPE, MN, USA) and kept in an oven at 37 °C for 24 hours. The samples, whose initial color measurements were made by spectrophotometer, were divided into subgroups for the control group and two different herbal teas (Green tea, Rosehip) (n=10). Color measurements were repeated, and ΔE values were calculated. Wilcoxon, Kruskal-Wallis, and Bonferroni tests were used to analyze the data (p < 0.05). Results: There was no statistically significant difference in color change between the composite resins ( p > 0.05). No significant color change was found for either the Tetric N-Ceram or Filtek Bulk-Fill composite resin samples immersed in distilled water ( p > 0.05, ΔE<3.3). Conclusion: Rosehip and green tea affect the color stability of composite resin restorations. Whereas the color change caused by green tea is at a clinically acceptable level, that stemming from rosehip tea falls within clinically unacceptable levels.   How to cite this article: Tunçdemir MT, Dereli Z, Bahar A. The effect of different herbal teas on the color stability of nanohybrid and bulk-fill composites. Int Dent Res 2022;12(Suppl.1):103-7. https://doi.org/10.5577/intdentres.445   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Herbal tea, green tea, rosehip tea, nanohybrid, bulk-fill composite resin, color stability
    Makbule Tuğba Tunçdemir, Zeynep Dereli, Ayşe Bahar
    31.12.2022
    103-107
    Abstract Views: 1327 Download: 672 DOI 10.5577/intdentres.445
  • Evaluation of shear bond strength of amalgam restorations repaired with composite resin by different surface treatments

    Aim: Repairing amalgam restorations with composite resins is a clinical practice with many advantages. An effective adhesion is achieved between amalgam and composite by applied different surface treatment on amalgam surface. In this study, the effect of adhesive systems applied on amalgam surface on composite-amalgam connection was investigated. Methodology: Standard cavities were opened in 70 acrylic molds that had completed their polymerization and amalgams were placed in these cavities. Seven groups were randomly assigned to different surface treatments on amalgam. In group 1 only roughening with diamond bur , in group 2 acid etch, in group 3 acid application after roughening with diamond bur, in group 4 roughening with diamond bur and silane, in group 5 acid etch and silane, in group 6 roughening with diamond bur and Alloy Primer and finally 7. acid etch and Alloy Primer was applied in the samples. After the application of clearfil universal bond to all groups, composite resins were placed and polymerized. Shear bond strengths were tested with a Universal testing machine. Obtained data were evaluated by one way ANOVA and Tukey B tests. Results: In the statistical evaluation of the groups, the highest shear bond strength between amalgam-composite was seen in the 3rd group where both roughening with diamond bur and acid were applied together, and the lowest shear bond strength was seen in the first group with only roughening with diamond bur. The differences between the groups were statistically significant (p <0.05). Conclusion: The roughening of the amalgam surface affects the shear bond strength between amalgam and composite resin. These results obtained in vitro conditions should be supported with clinical studies.   How to cite this article: Cangül S, Adıgüzel Ö, Erpaçal B, Ünal M, Acartürk M, Satıcı Ö. Evaluation of shear bond strength of amalgam restorations repaired with composite resin by different surface treatments. Int Dent Res 2019;9(3):105-10.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    amalgam, composite, shear bond strength
    Suzan Cangül, Özkan Adıgüzel, Begüm Erpaçal, Mehmet Ünal, Musa Acartürk, Ömer Satıcı
    31.12.2019
    105-110
    Abstract Views: 2565 Download: 854 DOI 10.5577/intdentres.2019.vol9.no3.3
  • A Composite Laminate Veneer Technique for Diastema Closure: A Report of Ten Cases

    Aim: Diastemas can be treated using periodontal, surgical, orthodontic, or prosthetic procedures. Composite laminate veneers can be applied to reduce or eliminate diastemas and represent a good aesthetic non-invasive alternative for these patients. This study presents the treatment results of 10 patients with diastemas between the anterior teeth of the maxilla and mandible with composite veneers. Methodology: Ten patients with diastemas between the anterior maxillary and mandibular teeth complaining of esthetic problems were treated at the Department of Operative Dentistry, University of Dicle. The periodontal health of the patients was acceptable and no caries were detected. Patients were informed of the treatment choices and composite resin veneers were selected as the better approach for each case. The presence of a diastema causes esthetic problems, especially in adolescents. Prosthetic and conservative methods are usually used to treat diastemas because these approaches are minimally invasive. The direct laminate technique has the advantages of low cost, treatment reversibility, and easy repair of the restoration intraorally. The direct composite laminate technique has become more effective because of improvements in adhesive dentistry. Conclusion: This study describes a direct composite laminate technique for the restoration of the anterior teeth of 10 patients with diastemas. These restorations were conservative and provide an inexpensive, one-visit aesthetic treatment for anterior teeth.  How to cite this article:  Bahşi E, Callea M, İnce B, Montanari M, Dallı M, Batteli F, Akdoğan M, Gabriella C, Toptancı İR, Gabriela P, Yavuz İ. A Composite Laminate Veneer Technique for Diastema Closure: A Report of Ten Cases. Int Dent Res 2012;2:67-74. Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Diastema closure, esthetic treatment, composite laminate
    Emrullah Bahşi, Michele Callea, Bayram İnce, Marco Montanari, Mehmet Dallı, Filippo Batteli, Mehmet Akdoğan, Clarich Gabriella, İsmet Rezani Toptancı, Piana Gabriela, İzzet Yavuz
    15.12.2012
    67-74
    Abstract Views: 2748 Download: 778 DOI 10.5577/intdentres.2012.vol2.no3.2
  • Effect of repolishing on the surface roughness and color stability of air-abraded resin composites

    Aim: Air powder polishing (APP) can cause roughness on composite surfaces, and consequently the color change that occurs over time affects the aesthetic negatively. Here, we aim to investigate the effect of repolishing on the roughness and discoloration of resin composites after APP to avoid its negative effects for the first time. Methodology: A total of 39 composite discs were randomly allocated into three groups: Group I: Control (n = 13), Group II: Air Powder Polished (n = 13), and Group III: Air Powder Polished + Re-polished (n = 13). Color and surface roughness of the discs were measured before and after immersion in coffee for 1 week. Color was measured using a colorimeter (CR-400, Konica Minolta), and roughness was measured using a surface roughness analyzer (SJ-400, Mitutoyo, Japan). Results: All specimens in the groups, except those in Group III, showed significant changes in roughness, and all materials showed significant color changes after immersion in the coffee relative to the baseline. There was no statistically significant difference between the groups in terms of roughness and color. Conclusion: In this study, we showed that repolishing after APP does not significantly improve the color stability and roughness of the composite restorations.   How to cite this article: Altaş N, Sağır K, Aydınoğlu A, Gözetici Çil B, Keleşoğlu E, Sağır K, Hazar Yoruç AB. Effect of repolishing on the surface roughness and color stability of air-abraded resin composites. Int Dent Res 2022;12(3):137-42. https://doi.org/10.5577/intdentres.2022.vol12.no3.5   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Dental air abrasion, surface roughness, repolishing, composite resin, colorimeter, coloring agent
    Nurcan Altaş, Aysu Aydınoğlu, Burcu Gözetici Çil, Ergün Keleşoğu, Kadir Sağır, Afife Binnaz Hazar Yoruç
    31.12.2022
    137-142
    Abstract Views: 1977 Download: 619 DOI 10.5577/intdentres.2022.vol12.no3.5
  • Evaluation of color stability after the application of a bleaching agent to different composite resins

    Aim: In dentistry, it is desirable to preserve the properties of composites for a long time. With the development of technologies, the number of different composites used in dental treatment has increased. With contemporary patients’ aesthetic expectations, bleaching treatmens are often sought, and the literature contains many studies on the effects of bleaching on composites. Our study aimed to examine the color stability of different types of composites immersed in different solutions after bleaching treatment. Methodology: A total of 72 samples (n = 8) of three composite materials were examined: Omnichroma (Tokuyama Dental Co., Tokyo, Japan), Estelite Posterior (Tokuyama Dental Co., Tokyo, Japan), and Quadrant (Cavex, Holland BV, Netherlands). All specimens were subjected to Total Blanc (Nova DFL, Rio de Janeiro, Brazil), which is an office-type bleaching agent. After bleaching treatments, the specimens were immersed in distilled water. The baseline measurements were then recorded. After being immersed in distilled water, tea, or coffee for seven days, the final color measurements were recorded. A VITA Easy Shade device (Vita Zahnarzt, Bad Säckingen, Germany) was used to take color measurements. The CIEDE2000 formula was used to calcuate ΔE 00 values. The Kruskal–Wallis test was used to compare the ΔE 00 values obtained from the composite samples to assess color stability. The results were rated at a significance level of p < 0.05. Results: After bleaching treatments, the interaction between the different composites and the solutions in which they were immersed had a statistically significant effect on ΔE 00 values ( p < 0.05). The highest mean value was obtained with the quadrant composite material that was immersed in the coffee solution. Conclusion: It is clear that tea and coffee cause discoloration in dental composites after bleaching treatments. Due to the sorption of these solutions into the composite structure, dentists should warn patients to be cautious about consuming beverages after bleaching.   How to cite this article: Köse HD, Güner Z. Evaluation of color stability after the application of a bleaching agent to different composite resins. Int Dent Res 2022;12(Suppl.1):79-84. https://doi.org/10.5577/intdentres.453   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Tooth bleaching, color stability, composite resin, CIEDE2000
    Hazal Deniz Köse, Zehra Güner
    31.12.2022
    79-84
    Abstract Views: 1746 Download: 582 DOI 10.5577/intdentres.453
  • A micro-computed tomography evaluation of the change in volume of different bulk-fill composite materials caused by polymerization shrinkage

    Aim: Composite resins contain different monomers and fillers that are directly affected by polymerization shrinkage.  Therefore, an accurate and reliable method is needed to measure the volume changes. The aim of this study was to evaluate the amount of volume change associated with polymerization shrinkage in four different bulk-fill composite materials in class II restorations using a micro-CT device, which has high resolution and provides 3-dimensional images. Methodology: A total of 40 human 3rd molar teeth were used. First, standard class II cavities were opened on the mesial surfaces of all the teeth, and then the first micro-CT images were obtained. The same adhesive material was applied to all the teeth. The teeth were then separated into four groups, and a different bulk-fill composite was applied to each group; Filtek (FTK), X-tra Fil (XTF), Tetric Evo Ceram (TEC), and Filtek One (FLO) and the second micro-CT images were obtained. Then after polymerization of the materials, the final micro-CT images were taken, and analyses were made according to the scanning results. The Kruskal Wallis and Mann Whitney U-tests were used in the statistical evaluation of the data.  Results: The volumetric gap formed after polymerization of the composite resins was not determined to be statistically significant (p>0.05). Conclusion: The volumetric difference (%) between the composite resin and the dental tissue following polymerization was seen to be greatest in XTF and least in FTK. It was concluded that the volumetric gap caused by the polymerization shrinkage of the tested materials may be due to the structure of the material.   How to cite this article: Cangül S, Adıgüzel Ö, Sağmak S, Evran B. A micro-computed tomography evaluation of the change in volume of different bulk-fill composite materials caused by polymerization shrinkage. Int Dent Res 2021;11(2):75-82. https://doi.org/10.5577/intdentres.2021.vol11.no2.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    Micro-CT, bulk-fill composite, volumetric gap, polymerization shrinkage
    Suzan Cangül, Özkan Adıgüzel, Savaş Sağmak, Begüm Evran
    31.08.2021
    75-82
    Abstract Views: 2974 Download: 830 DOI 10.5577/intdentres.2021.vol11.no2.4
  • Effects of surface treatments on the bond strength of glass hybrid restorative system repaired with hybrid composite resin

    Aim: To assess the bonding strength of the Equia Forte resin modified glass ionomer cement to the hybrid composite material by applying different surface treatments. Methodology: 140 samples as 70 Equia Forte and 70 G-eanial composites were produced as 8 mm diameter 3 mm high cylindrical standardized samples. The samples were divided into 7 groups to treat surfaces. G-eanial composite resins as 4 mm diameter 3 mm high was placed onto the samples and polymerized. Then 1000 thermal cycle was applied and samples were mounted in the universal testing machine. Obtained bond strength values were recorded as Newton. One way Anova and Scheffe post hoc tests were performed for statistics. Results: In the G-aenial group, the highest bond strength was obtained with laser-bond method (N=17.71, P<0.05) and the lowest bonding strength was obtained with only laser-treated method (N=3.45, P<0.05). In the Equia group, the highest bond strength was obtained with air abrasion-bond method (N=9.29, P<0.05) and the lowest bonding strength was obtained with only laser-treated method (N=0.00, P<0.05). Conclusion: The fact that sufficient bond strength could not be reached by any surface treatment in Equia Forte may suggest that replacing the Equia Forte instead of repairs may be a better choice.   How to cite this article:  Arıcıoğlu B, Hatipoğlu Ö. Effects of surface treatments on the bond strength of glass hybrid restorative system repaired with hybrid composite resin. Int Dent Res 2018;8(3):131-8.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Bond strength, repair, surface treatment
    Banu Arıcıoğlu, Ömer Hatipoğlu
    30.12.2018
    131-138
    Abstract Views: 1915 Download: 1063 DOI 10.5577/intdentres.2018.vol8.no3.6
  • Examination of the Effect of Preheating Process on Microtensile Bond Strength in the Cementation of Indirect Restorations The Effect of Preheating Process on Microtensile Bond Strength

    Aim: The aim of this study was to investigate the effect of preheating of inlay and onlay restorations prepared from composite materials and using a CAD/CAM device on microtensile bond strength in different structures. Methodology: In this study, 90 impacted human third molar teeth unaffected by the mouth environment were used. These teeth were divided into 3 groups. MOD inlay cavity preparation was performed on all samples according to the parameters specified. For the first group, restorations were prepared using a CAD/CAM device. For the second group, a fiber-reinforced composite (EverX Posterior, GC, Tokyo, Japan) was used on the bottom of the cavity to simulate dentin structure. Restoration was then completed using the laboratory composite system (Gradia, GC, Tokyo, Japan). For the third group, restorations were completed using the laboratory composite system (Gradia, GC, Tokyo, Japan) alone. Er,Cr:YSGG laser (Fotona Laser AT Fidelis Plus III, Slovenia) was administered on all prepared restorations for surface roughening. In the cementation of the restorations, resin cement was administered with and without preheating. The prepared samples were placed in a microtensile tester, and the sticks were broken off by setting the loading speed at 1 mm/min. The prepared samples were tested for microtensile bond strength (Microtensile Tester, Bisco, Schaumburg, IL, USA). The results obtained in Newtons were divided into the surface area and converted to MPa. The results were recorded as microtensile bond strength values. Results: There was no statistically significant difference between the groups in terms of the statistical evaluation of the microtensile bond strengths of the samples in which the adhesive cement was pre-heated (P) and not pre-heated (N) during the cementations (p>0.05). There was a statistically significant difference (p<0.05) in terms of the microtensile bond strength values between the groups in which the adhesive cement was pre-heated during the cementation of restorations. Conclusion: It was observed that exposure of the adhesive cement to preheating in the cementation of the EverX Posterior-based inlays adversely affects the bond strength. It was observed that the preheating process statistically significantly increased the bond strength in the inlays made using the Gradia composite. Preheating of the cement in the cementation of Cerasmart composite inlays produced using the CAD/CAM system did not affect the microtensile bond strength.       
    Preheating, CAD/CAM, microtensile, fiber-reinforced composite
    Zuhal Görüş
    30.04.2018
    15-21
    Abstract Views: 1729 Download: 990 DOI 10.5577/intdentres.2018.vol8.no1.3
  • Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study

    Aim: Using AutoCAD, we examined the microleakage of permanent molars in Class I restorations using a conventional posterior composite resin, a bulk-fill composite resin, and a high-viscosity glass-ionomer cement (HVGIC). Methodology: In total, 33 extracted noncarious third molars were used. Class I cavities were prepared. The teeth were randomly divided into three groups of 11 teeth each, as follows: Group A (Filtek Z550), Group B (Filtek Bulk-Fill Posterior Restorative), and Group C (EQUIA Fil). All specimens were stored for 24 h at 37 °C in distilled water. The teeth were thermocycled 1,000 times between 5 ± 2°C and 55 ± 2°C prior to immersion in 0.5% basic fuchsin for 24 h. Two mesiodistal cuts of each tooth were photographed under a stereomicroscope equipped with a digital camera. The dye-infiltrated surface area was measured. Results: Statistical evaluations were performed by one-way analysis of variance [ANOVA]. One-way ANOVA showed no significant difference between the three groups in microleakage (P = 0.07). However, the lowest microleakage ratio was seen in Group C (EQUIA Fil).  Similar results were obtained with all tested materials, but the lowest microleakage rate was obtained with EQUIA Fil (Group C). Conclusion: In this study, the tested materials were not completely successful in eliminating microleakage, although the lowest microleakage rate was obtained with EQUIA Fil.   How to cite this article: Çelenk S, Ataş O, Ayna B, Günay A. Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study. Int Dent Res 2022;12(1):34-8. https://doi.org/10.5577/intdentres.2022.vol12.no1.6   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    composite resin, high-viscosity glass-ionomer cement, microleakage, AutoCAD
    Sema Çelenk, Osman Ataş, Buket Ayna, Ayşe Günay
    30.08.2022
    34-38
    Abstract Views: 1676 Download: 576 DOI 10.5577/intdentres.2022.vol12.no1.6
  • Comparison of different standardised bond strength tests and the influence of glycine powder treatment in composite resin repairs

    Aim: The repair of restorations is an eligible method to extend the survival rates of intraoral restorations. There is a consensus that the old surface has to be removed before repair by the use of a sandblaster or rotating instruments. This study aimed to investigate whether a glycine powder can be used successfully in composite repair by measurement of shear and tensile bond strength according to dental standards. Methodology: The influence of mechanical preparation by no powder, 25 µm glycine powder or 50 µm aluminium-oxide powder and chemical conditioning by the use of bonding, phosphoric acid and bonding or bonding, phosphoric acid and a silane on the repair bond strength of an artificially aged nano-hybrid composite was tested according to the guidelines of DIN 13990 (2017), ISO 29022 (2013) and ISO/TS 11405 (2015). The fracture modes were evaluated by adhesive, cohesive or mixed failures. Results: There was no significant difference in the performance of the different mechanical and chemical treatments. The shear bond test according to DIN 13990 (2017) produces higher repair bond strengths (26.0±8.9 MPa) than the test described in ISO 29022 (17.9±6.3 MPa). The tensile bond strength according to ISO/TS 11405 (6.9±1.8 MPa) was the lowest. Most adhesive failures occurred with the shear test according to ISO 29022 (41%), followed by DIN 13990 (18%) and the tensile test (4%). Conclusion: For evaluating the bond strength of composites the test described in ISO 29022 is recommended, because it produces the highest percentage of adhesive failures. Nano-hybrid-composites are robust to different repair protocols.   How to cite this article: Herrmann GP, Reimann S, Daratsianos N, Weber A, Keilig L, Nadal J, Bourauel C. Comparison of different standardized bond strength tests and the influence of glycine powder treatment in composite resin repairs. Int Dent Res 2020;10(1):36-43. https://doi.org/10.5577/intdentres.2020.vol10.no2.2     Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Composite resin, repair, sandblasting, bond strength test
    Gregor Herrmann, Susanne Reimann, Nikolaos Daratsianos, Anna Weber, Ludger Keilig, Jennifer Nadal, Christoph Bourauel
    31.08.2020
    36-43
    Abstract Views: 2111 Download: 2480 DOI 10.5577/intdentres.2020.vol10.no2.2
  • Examination of stress distributions on Class V restorations using nanohybrid resin composite: A 3D finite element stress analysis

    Aim: The aim of this study was to investigate and compare the distribution of stress zones in composite resins and dental tissues applied to different-sized Class V cavities in the cervical region of the tooth as a result of the forces acting on the tooth in a computer environment using the finite element method. Methodology: The extracted lower first molar tooth was scanned and recorded with a dental tomography device. Images were obtained as DICOM files, and these files were imported into the Mimics 12.00 program. In this program, a 3D image of the tooth was created and converted to Standard Tessellation Language (STL) files. The obtained STL files were transferred to the Geomagic Design X program, and Standard for the Exchange of Product Model Data (STP) files were created. The SolidWorks program was used to create different sizes of Class V cavity preparation, restorative material layers, adhesive material layers, and periodontal tissues. Finally, a finite element (FE) model was created in the ABAQUS program, and stress distributions were analyzed. Results: When the depth was kept constant and the width was increased, the amount of stress on the enamel tissue decreased, while the amount of stress on all other tissues and the restorative material increased. When the width was kept constant and the depth was increased, the amount of stress on the restorative material, adhesive layer, and cortical bone increased, while the amount of stress on the enamel layer, dentin layer, periodontal ligament, and trabecular bone decreased. Conclusion: Based on the values found in the study, the model that produced the least stress on the restorative material was the model with the least depth and width. However, the stress accumulation in the enamel tissue was higher in this model compared to the other models. As a result, the lifespan of restorative materials may be longer in cavities prepared more shallowly and narrowly during the preparation phase.   How to cite this article: Harmankaya A, Gönder HY, Mohammadi R, Karaköy H, Tunçdemir MT, Yüksel İB, Göktolga EG. Examination of stress distributions on Class V restorations using nanohybrid resin composite: A 3D finite element stress analysis. Int Dent Res. 2024;14(S1):90-97. https://doi.org/10.5577/indentres.562
    Finite element analysis, nanohybrid, composite, Class V, Von Mises stress
    Abdulkadir Harmankaya, Hakan Yasin Gönder, Reza Mohammadi, Hilal Karaköy, Makbule Tuğba Tunçdemir, İbrahim Burak Yüksel, Emine Gülşah Göktolga
    31.12.2024
    90-97
    Abstract Views: 2487 Download: 487 DOI 10.5577/indentres.562
  • Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays

    Aim: The aim of the study was to evaluate the fracture resistance and microleakage of different CAD-CAM inlay restorations. Methodology: Inlay restorations from nine restorative materials as monolithic zirconia (TZI), resin nano ceramic (LU), hybrid ceramic (VE), feldspathic ceramic (CB), zirconia reinforced lithium silicate (VS), lithium disilicate (e.max), leucite reinforced glass ceramic (Emp), resin ceramic (GCS), and conventional composite resin (CR) were used (n=10). For evaluating the fracture resistance, restorations were cemented to resin teeth and subjected to thermomechanical aging. The data of fracture resistance were analyzed using One-way Analysis of Variance (ANOVA) and Games-Howel tests (a=0.05). For evaluating the microleakage, restorations were cemented on human teeth and subjected to thermocycling. The teeth were vertically sectioned into two parts and microleakages were assessed as yes or no.  Results: The highest and lowest fracture resistance values were found in TZI and LU groups, respectively ( p >0.05). The most frequent microleakage was observed in TZI and CR groups, and the least microleakage was seen in the VE group. Microleakage was frequently found in cervical surfaces and followed by occlusal, axial, and pulpal surfaces. Conclusion: Hybrid ceramics showed similar fracture resistance with the monolithic zirconia; besides, the lowest microleakage was observed for these ceramics. Hybrid ceramics may be a good alternative for inlay restorations.   How to cite this article: Bankoğlu Güngör M, İnal CB, Hürbağ M, Toksoy B, Turhan Bal B, Karakoca Nemli S. Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays. Int Dent Res 2024;14(1):10-18. https://doi.org/10.5577/intdentres.324
    CAD-CAM, ceramic, inlays, aging, fracture resistance, microleakage
    Merve Bankoğlu Güngör, Ceyda Başak İnal, Meryem Hürbağ, Burcu Toksoy, Bilge Turhan Bal, Seçil Karakoca Nemli
    30.04.2024
    10-18
    Abstract Views: 1477 Download: 533 DOI 10.5577/intdentres.324
  • The effect of cold drinks on the coloration of resin-containing restorative materials

    Aim: Resin-containing restorative materials are widely used in the restoration of teeth. Our aim in this study is to examine the color change of beverages consumed cold on resin-containing restorative materials. Methodology: Samples were prepared using composite resins and resin-based CAD/CAM blocks. All prepared samples were kept in cold tea, cold coffee, coke, energy drink, and distilled water after polishing. The color values of the samples were measured with a spectrophotometer at the beginning, on the 1st, 7th and 30th days, and the color change values were calculated with the CIEDE2000 formula. Statistical analysis of color change values was performed using two-way analysis of variance (ANOVA) and Tukey multiple comparison tests (p<0.05). Results: While there was no statistically significant difference in the color changes of the resin-containing dental materials at the end of the 1st day (p>0.05), at the end of the 7th and 30th days, cold tea caused the statistically highest color change (p<0.05). There was no statistically significant difference between the color change values of cold coffee, coke and energy drink on the materials in all time periods (p>0.05). Composite resins showed more color change than resin-based CAD/CAM blocks (p<0.05). Conclusion: Cold tea causes the most discoloration on resin-based materials. While the resin-containing CAD/CAM blocks showed a color change under the AT value in all cold drinks, the composite resins showed a color change above the AT value in cold tea and coffee.   How to cite this article: Altıparmak ET, Aybala Oktay E, Karaoğlanoğlu S, Aydın N, Ersöz B, Özarslantürk S. The effect of cold drinks on the coloration of resin-containing restorative materials. Int Dent Res 2022;12(1):14-20. https://doi.org/10.5577/intdentres.2022.vol12.no2.3   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    CAD/CAM, composite resin, color change, cold drinks
    Elif Tuğba Altıparmak, Elif Aybala Oktay, Serpil Karaoğlanoğlu, Numan Aydın, Bilge Ersöz, Savaş Özarslantürk
    30.08.2022
    14-20
    Abstract Views: 1631 Download: 834 DOI 10.5577/intdentres.2022.vol12.no2.3
  • The effect of different surface treatments on the color change of CAD/CAM restorative materials caused by coffee

    Aim: This study aimed to evaluate the effect of different surface treatment protocols on the color stability of two CAD/CAM restorative materials, a hybrid ceramic (Vita Enamic) and a resin-based composite (Shofu Block HC), when exposed to filter coffee. Methodology: Sixty disk-shaped specimens (12 mm diameter, 1.5 mm thickness) were prepared from Vita Enamic and Shofu Block HC. The specimens were divided into six groups (n=10) based on the material and surface treatment: Mechanical Polishing Only, Glaze (Optiglaze) Only, and Mechanical Polishing + Glaze. After the surface treatments, baseline color measurements were performed using a spectrophotometer (Vita EasyShade V). The specimens were then immersed in a freshly prepared filter coffee solution, which was renewed daily for 15 days (simulating ~3 years of clinical exposure). Post-immersion color measurements were taken, and the color difference (ΔE) and lightness difference (ΔL) were calculated. Data were analyzed using two-way ANOVA and Tukey's HSD test (p < 0.05). Results: Two-way ANOVA revealed significant main effects of Material and Surface Treatment on both ΔE and ΔL (p < 0.001). A significant Material × Surface Treatment interaction was found for ΔL (p = 0.012) but not for ΔE (p = 0.207). Vita Enamic demonstrated significantly lower ΔE and higher ΔL values than Shofu Block HC, indicating better overall color stability and less darkening. For both materials, Mechanical Polishing Only resulted in significantly lower ΔE than glaze only or the combination group. For ΔL, Mechanical Polishing was superior for Vita Enamic, whereas Glaze Only yielded the most unfavorable results for Shofu Block HC. Conclusion: The color stability of CAD/CAM materials is significantly influenced by both material composition and surface treatment applied. Mechanical polishing provided the best color stability for both materials tested. Clinically, for restorations prone to coffee exposure, selecting a hybrid ceramic like Vita Enamic and finishing it with mechanical polishing is recommended to optimize long-term aesthetic performance.
    CAD-CAM, color stability, dental polishing, composite resin, coffee, surface properties
    Meryem Erdoğdu, Gözde Kaya Oğuz, Merve Karagöz, Ali Rıza Tunçdemir, Emine Begüm Büyükerkmen
    31.12.2025
    183-194
    Abstract Views: 798 Download: 244 DOI 10.5577/intdentres.670
  • Investigation of microleakage of polymerized with LED and halogen light devices four different restorative materials

    Aim: This study aimed to evaluate the in vitro effects on microleakage of LED and halogen light devices used in the polymerization of monomer structure composite resins of different viscosities and inorganic filling particle size applied to standard class V cavities in primary teeth. Methodology: 80 non caries primary molar teeth with standard class v cavity on the buccal surfaces were used. The teeth were randomly divided into 4 main groups and restored with composite resins (Herculite® XRV, Ultra™, Filtek™ Silorane, Vertise™ Flow, Æliteflo™). Each group was divided into 2 sub-groups for polymerization with LED or halogen light devices. Following the thermal cycle and subsequent procedures, the dye penetration method was used to evaluate microleakage. The microleakage scores were evaluated using the Kruskal-Wallis and Mann-Whitney U-tests. Results: According to the results of the statistical analysis, in polymerization made with halogen and LED light devices at the occlusal edge, the microleakage scores from lowest to highest were as follows: Filtek™ Silorane < Herculite® XRV Ultra™ < Æliteflo™ < Vertise™ Flow. In polymerization made with halogen and LED light devices at the gingival edge, the microleakage scores from lowest to highest were as follows: Filtek™ Silorane < Herculite® XRV Ultr™ < Vertise™ Flow < Æliteflo™. Conclusion: In the polymerizations made by using LED and halogen light devices, Herculite® XRV Ultra™, was found to be successful as it showed similar values to Filtek™ Silorane, which gave the best results in terms of microleakage. Moreover, as we have reached similar findings in our thesis study in respect of microleakage, in cases indicating the use of flow composite resin materials such as Æliteflo™, Vertise™ Flow can be used as it has the advantage of ease application and thus provide an ideal alternative in pediatric dentistry.   How to cite this article: Günay A, Tümen EC. Investigation of microleakage of polymerized with LED and halogen light devices four different restorative materials. Int Dent Res 2020;10(3):73-9. https://doi.org/10.5577/intdentres.2020.vol10.no3.2   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Primary tooth, microleakage, class V cavity, light devices
    Ayşe Günay, Emin Caner Tümen
    31.12.2020
    73-79
    Abstract Views: 1669 Download: 598 DOI 10.5577/intdentres.2020.vol10.no3.2
  • Evaluation of marginal microleakage in composite restorations with different placement techniques

    Aim: The purpose of this in vitro study was to evaluate the effect of different layering techniques (bulk, oblique, centripetal, split horizontal) on the marginal microleakage of Class II adhesive restorations. Methodology: Forty-eight standardized Class II cavities were prepared on both mesial and distal sides of extracted non-carious human molar teeth. Following preparation, all specimens were randomly divided into four groups (n=12). Group 1: bulk technique; Group 2: oblique incremental technique; Group 3: centripetal incremental technique; Group 4: split horizontal incremental technique. The teeth were restored with a total-etch adhesive system and a microhybrid composite resin. After thermocycling and immersion in a 0.2% methylene blue solution for 24 hours, the restorations were sectioned, and dye penetration was evaluated under a stereomicroscope. The microleakage scores (0 to 4) obtained from the occlusal and gingival margins were analyzed with Kruskal-Wallis and Mann-Whitney U tests (p<0,05).   Results: Incremental placement techniques showed lower microleakage compared with bulk and lower microleakage was seen at occlusal margin compared with gingival margin. However, there were no statistically significant differences among four placement techniques and the margins (p>0,05). Conclusions: Based on the results of the present study, none of the four placement techniques were found to be effective in eliminating marginal microleakage entirely in Class II restorations. All of the placement techniques showed similar results when the cavity margins were located on the enamel.   How to cite this article:  Misilli U, Yılmaz F. Evaluation of marginal microleakage in composite restorations with different placement techniques. Int Dent Res 2018;8(2):70-7.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Composite resin, incremental technique, microleakage, polymerisation shrinkage
    Umut Misilli, Fikret Yılmaz
    27.08.2018
    70-77
    Abstract Views: 2259 Download: 1193 DOI 10.5577/intdentres.2018.vol8.no2.4
  • The effect of thickness and cement shade on the color match of different CAD-CAM glass-ceramic materials

    Aim: This study aimed to assess the impact of the type and thickness of the ceramic and cement color on the targeted shade of glass-ceramics with various chemical compositions. Methodology: Thirty ceramic specimens were prepared from leucite-reinforced (GC Initial LRF, GC Group) and lithium-disilicate (IPS e.max CAD, EM Group) materials in three different thicknesses (0.5 mm, 0.7 mm, and 1 mm). Four 4-mm-thick substrates were then made from A3-shaded composite resin material to mimic tooth structure and be utilized for cement application. Four shades (Variolink II: transparent, white, yellow, and bleach) of 0.2-mm-thick resin cement were polymerized over these substrates. Next, the specimens were placed over these substrates, and color measurements were applied with a spectrophotometer (VITA Easyshade V) leading to 24 group combinations (n=5). The color difference (∆E) readings were obtained in the spectrophotometer's reference shade verification mode by selecting the A2 shade standard. Three-way mixed ANOVA, Tukey HSD, and Bonferroni tests were used for statistical analysis (α=0.05). Results: The main effects of material, cement, and thickness were found to be statistically significant ( p < 0.05), as were the interactions of cement×material, cement×thickness, and material×thickness ( p < 0.05). However, the material×cement×thickness interaction was not found to be statistically significant ( p = 0.568). Regardless of thickness or cement shade, the GC group had a lower mean ∆E value than that of the EM group ( p < 0.05). Lower ∆E values were achieved in both materials with a thickness of 1 mm and bleach-shaded cement ( p < 0.05). The materials with the greatest mean ∆E values were those with the thickness of 0.5 mm and the transparent shade cement combination ( p < 0.05). Conclusion: The thickness and shade of the cement used influenced the final color of the glass-ceramic materials with the same shade and translucency but diverse chemical compositions. When compared to the lithium disilicate glass-ceramic material, the leucite-reinforced feldspathic glass-ceramic material displayed lower color difference values and a better color match with the targeted shade.   How to cite this article: Yılmaz Savaş T. The effect of thickness and cement shade on the color match of different CAD-CAM glass-ceramic materials. Int Dent Res 2022;12(Suppl.1):108-13. https://doi.org/10.5577/intdentres.457   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    CAD-CAM, cement color, color difference, leucite, lithium disilicate, spectrophotometer
    Tuba Yılmaz Savaş
    31.12.2022
    108-113
    Abstract Views: 1519 Download: 531 DOI 10.5577/intdentres.457
  • Evaluating the masking ability of CAD/CAM hybrid ceramics with different thicknesses

    Aim:  A discoloration existing under the restoration can affect the final restoration color, and various techniques can be used to address this situation. The aim of this study was to investigate the masking ability of the substructure, color of different hybrid CAD/CAM ceramics in various thicknesses. Methodology: A total of 120 samples were produced from 4 different CAD/CAM hybrid ceramic blocks (Cerec blocs, GC Cerasmart, Vita Enamic, 3M Lava Ultimate) in 1, 1.5 and 2 mm thickness. The samples were sliced with 100 N pressure in a low-speed precision cutting device under water cooling. The specimens were placed over the neutral grey background for initial spectrophotometric measurements. A3 color posterior nanohybrid composite (14 X 7 X 1 mm) was preferred to mimic discoloration in the substructure. The cementation procedure of composite and the CAD/CAM hybrid ceramic complex was standardized under 10 N continuous pressure and was performed using a dual cured resin cement. All samples were incubated at 37 °C for 24 hours in incubator after cementation. And the second spectrophotometeric measurement was done via the L*, a*, and b* color attributes of the complex specimens. Additionally, ΔE* values were calculated to determine the color differences between each group. Kruskal Wallis test was used for statistical analysis and Dunn’s test was used for group comparison. Significance was evaluated at least p <0.05. Results: It was found that thickness of the ceramics increases, the substructure color is better masked and the thickness made a statistically significant difference on the masking ability (p<0.01). For 1 mm thick samples, the highest ΔE* value was found in Cerec blocs with 9.36, while the lowest value was found in GC Cerasmart as 4.27. Conclusion: Within the limitations of this study, it was concluded that the tested CAD/CAM hybrid ceramics showed better masking ability than Cerec blocs.   How to cite this article: Ünalan Değirmenci B, Wahid WF. Evaluating the masking ability of CAD/CAM hybrid ceramics with different thicknesses. Int Dent Res 2021;11(2):114-20. https://doi.org/10.5577/intdentres.2021.vol11.no1.9   Linguistic Revision:  The English language in this manuscript has been checked by at least two professional editors, both native speakers of English.
    CAD-CAM, ceramics, tooth discoloration
    Beyza Ünalan Değirmenci, Farhad Wahid Rasool
    31.08.2021
    114-120
    Abstract Views: 1664 Download: 765 DOI 10.5577/intdentres.2021.vol11.no2.9
  • Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength

    Aim: In this in vitro study, the effect of two adhesive systems applied to surfaces of different polyether-ether-ketone (PEEK) composites on the shear bond strength (SBS) of a composite resin was compared. Methodology: Eighty PEEK specimens were divided into four groups (n=20): Unfilled PEEK (UF), carbon-fiber-reinforced PEEK (CFR), glass-fiber-reinforced PEEK (GFR), and ceramic-reinforced PEEK (CR). Each group was further divided into two subgroups (n=10): Visio.link (VL) and Single Bond Universal (SB). The specimens with 8-mm diameter and 5-mm thickness were prepared. SBS was examined using a universal testing machine. Results were statistically analyzed by multivariate analysis of variance and Tukey’s post-hoc test. Failure modes were analyzed using a stereomicroscope at 20× magnification. Surface properties were examined by scanning electron microscopy. The surface properties of the specimens were examined by scanning electron microscopy (SEM).  Results: Effect of different PEEK and adhesive systems on SBS was found to be statistically significant (p<0.05). SBS values for CFR-VL and UF-VL groups were statistically more significant than those for CFR-SB and UF-SB groups (p=0.001). SBS values for the GFR-VL group were statistically more significant than that for the UF-VL group (p=0.001). SBS values for the CF-SB group were statistically more significant than those for CFR-SB and CFR-SB groups (p=0.001). Failure modes were examined using a stereomicroscope at 20× magnification, and adhesive and mixed failure modes were observed. Conclusion: PEEK composites with different contents and properties can be used in fixed prosthetic restorations. However, additional experimental and clinical studies are required to investigate different PEEK frameworks and composite veneers.   How to cite this article: Demirci F, Tekin S. Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength. Int Dent Res 2021;11(2):54-61. https://doi.org/10.5577/intdentres.2021.vol11.no2.1   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    adhesion, PEEK, PEEK composites, Polyetheretherketone, shear bond strength, veneering
    Fatih Demirci, Samet Tekin
    31.08.2021
    54-61
    Abstract Views: 1866 Download: 1136 DOI 10.5577/intdentres.2021.vol11.no2.1
  • Emergency Aesthetic Approaches to Patients with Body Dysmorphic Disorder: Report of Three Cases

    Body dysmorphic disorder (BDD) is an obsessive preoccupation with a perceived defect in one’s physical appearance for which the individual persistently seeks medical attention and surgical correction. This preoccupation can be persistent and pervasive, leading to social withdrawal.  A dentist may be the first health care worker who has an opportunity to intervene and assist these people in getting treatment. Patients may have unrealistic expectations for certain procedures, so assessing their psychological status is an important part of treatment planning and diagnosis. Patient expectations should be determined, and the ability to provide care that meets those expectations should be discussed. In the case reports, aesthetic treatments with composite resin restorations of three patients with BDD are reported. The cases highlight the need for dentists to be educated on this disorder so that they can recognize and refer accordingly. There is also a need for interdisciplinary interactions between the dentist and the psychologist. How to cite this article:  Sezgin Bolgül B, Ağaçkıran E, Tümen EC, Ayna Y, Çelenk S, Ayna B. Emergency Aesthetic Approaches to Patients with Body Dysmorphic Disorder: Report of Three Cases. Int Dent Res 2011;3:87-91. Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Body dysmorphic disorder, physical appearance, aesthetic dentistry
    Behiye Sezgin Bolgül, Engin Ağaçkıran, Emin Caner Tümen, Yunus Ayna, Sema Çelenk, Buket Ayna
    15.12.2011
    87-91
    Abstract Views: 2778 Download: 546 DOI 10.5577/intdentres.2011.vol1.no3.3
  • Investigation of the effect of the application of different full ceramic materials on stress distribution to minimally invasive posterior fixed bridge restorations by finite element analysis

    Aim: The aim of this study was to examine the effect of different types of all-ceramic materials used in various designs of partial posterior indirect restorations on stress distribution through finite element analysis. Methodology: Intact mandibular first premolar and first molar teeth were selected. After being soaked in saline solution for a week, 3D radiographic images were taken using cone-beam computed tomography (CBCT). Following root canal treatment, preparations were made for inlay restorations on both teeth. CBCT images were taken again after the preparations. Data from CBCT scans were used to create 3D models in the Mimics program. Restoration designs were prepared in Standard Tessellation Language (STL) format using the EXOCAD program. The models were transferred to SolidWorks for collision processes with cement designs and then exported in Standard for the Exchange of Product Model Data (STP) format. These files were imported into the ABAQUS program for finite element analysis, with properties assigned for each restoration type. Vertical forces of 600 N were applied to the occlusal surfaces, and stress values were recorded in Von Mises Stress (VMS) values. Results: The results of the study showed that the VMS value on inlay bridge restorations was lower in mesio-occluso-distal inlay (MODI) compared to MO-DOI. ZLS exhibited the lowest VMS value for enamel loads, while nano-hybrid composite ceramics with resin matrix (RMNH) showed the lowest stress distribution in the restoration material. In posterior adhesive indirect bridge restorations, material rigidity reduced tooth load distribution. Thus, MODI preparations are preferable due to reduced stress on teeth. ZLS is advantageous as the restoration material for minimizing enamel stress. Conclusion: In cortical and trabecular bone, similar values were found across all three restorations. The highest stress concentration, excluding the area around the restoration, was observed in lithium disilicate.   How to cite this article: Aydın S, Tunçdemir AR, Mohammadi R, Demirel MG. Investigation of the effect of the application of different full ceramic materials on stress distribution to minimally invasive posterior fixed bridge restorations by finite element analysis. Int Dent Res. 2024;14(S1):28-35. https://doi.org/10.5577/indentres.572
    Inlay bridge, indirect restorations, stress distribution, finite element analysis, Von Mises stress
    Salih Aydın, Ali Rıza Tunçdemir, Reza Mohammadi, Mehmet Gökberkkaan Demirel
    31.12.2024
    28-35
    Abstract Views: 2137 Download: 506 DOI 10.5577/indentres.572
  • Endodontic retreatment of mandibular molars with the presence of missed middle mesial root canals: An important clinical lesion

    Aim: Untreated root canals may have a direct impact on root canal treatment (RCT) outcome. The aim of this case report is to describe the nonsurgical root canal retreatment of two mandibular first molars in a patient's mesial roots that had previously missed middle mesial root canals (MMC). Methodology: A 14-year-old female was referred to the our clinic with the complaint of pain in the posterior areas of the right and left mandibula. During the examination, previous RCTs [teeth 36 (mandibular left first molar) and 46 (mandibular right first molar)] were observed. Besides, these teeth have periradicular lesions in the mesial roots probably due to unsuccessful previous treatment. Nonsurgical retreatment was suggested and accepted. Access cavities were prepared and the unnoticed MMCs were detected at the isthmus connecting both mesiobuccal and mesiolingual canals. All the root canals were shaped with NiTi rotary endodontic files. During the shaping, the root canals were irrigated copiously with NaOCl, EDTA, clorhexidine, and saline solutions under a certain protocol. Calcium hydroxide was used for intracanal dressing. Gutta-percha and a resin-based root canal sealer were used for filling. Coronal restorations of the teeth were completed with a composite resin. Conclusion: At follow-up examinations after 3-, 6-, and 12-months, the teeth were asymptomatic and radiographically showed repair of the lesion. Healing was achieved without any need for further endodontic surgical intervention.     How to cite this article: Başoğlu A, Harorlı H, Er K. Endodontic retreatment of mandibular molars with the presence of missed middle mesial root canals: an important clinical lesion. Int Dent Res 2023;13(2):99-103. https://doi.org/10.5577/idr.2023.vol13.no2.8   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Anatomy, case report, endodontic retreatment, middle mesial canal
    Abdullah Başoğlu, Hatice Harorlı, Kürşat Er
    31.08.2023
    99-103
    Abstract Views: 1857 Download: 739 DOI 10.5577/idr.2023.vol13.no2.8
  • Evaluation of stress distribution in maxillary central incisor restored with different post materials: A three-dimensional finite element analysis based on micro-CT data

    Aim: Post-core restorations have been developed to restore and re-functionalize endodontically treated teeth. Today, post-core materials used to show stress distribution similar to a solid tooth are still being researched. This study aimed to compare the von Mises stress (σvm) distributions created by the Zirconium post (ZP), Titanium post (TP), and Glass Fiber post (GFP) materials in the permanent maxillary central incisor using finite element stress analysis (FEA). Methodology: A permanent maxillary central incisor tooth scanned using microcomputed tomography (µCT) was reconstructed, and a three-dimensional model was created. To these models, ZP, TP, and GFP were applied. Composite resin was modeled as the core structure and ceramic crown as the superstructure. Using FEA, 100 N static force was applied in three directions with vertical (F1-0°), oblique (F2-45°), and horizontal (F3-90°) angles to the models whose restoration was completed. As a result of the applied forces, the stresses on the dentine model (Dm), post model (Pm), and the cement model in between the dentine and the post (Cm) were compared. Results: The maximum von Mises stress (σvm max) distribution under F1 for Dm was: ZP = 6,07888 MPa, TP = 6,35719 MPa and GFP = 6,81946 MPa. The σvm max distribution under the force F2 for Dm was: ZP = 26,6542 MPa, TP = 27,3694 MPa, and GFP = 28,4495 MPa. The σvm max distribution under the force F3 for Dm was: ZP = 34,7371 MPa, TP = 34,9828 MPa, and GFP = 35,287 MPa. The σvm max distribution under the force F1 for Pm was: ZP = 17,0361 MPa, TP = 13,1567 MPa, and GFP = 7,85452 MPa. The σvm max distribution under the force F2 for Pm was: ZP = 73,7999 MPa, TP = 52,0089 MPa, and GFP = 25,9903 MPa. The σvm max distribution under the force F3 for Pm was: ZP = 78,8934 MPa, TP = 55,0424 MPa, and GFP = 27,1787 MPa. The σvm max distribution under the force F1 for Cm was: ZP = 7,95074 MPa, TP = 6,66092 MPa, and GFP = 4,60832 MPa. The σvm max distribution under the force F2 for Cm was: ZP = 16,8296 MPa, TP = 16,8514 MPa, and GFP = 16,526 MPa. The σvm max distribution under the force F3 for Cm was: ZP = 17, 5577 MPa, TP = 16,891 MPa, and GFP = 16,5209 MPa. Conclusion: In all three forces, the highest σvm max was at ZP, and the least was at GFP. ZP and TP accumulated forces internally rather than transmitting them to the tooth tissue. GFP distributed the forces more homogeneously to the dentine.   How to cite this article: Yeniçeri Özata M, Adıgüzel Ö, Falakaloğlu S. Evaluation of stress distribution in maxillary central incisor restored with different post materials: A three-dimensional finite element analysis based on micro-CT data. Int Dent Res 2021;11(3):149-57. https://doi.org/10.5577/intdentres.2021.vol11.no3.3   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    stress distribution, zirconium post, glass fiber post, titanium post, finite element analysis
    Merve Yeniçeri Özata, Özkan Adıgüzel, Seda Falakaloğlu
    31.12.2021
    149-157
    Abstract Views: 2614 Download: 845 DOI 10.5577/intdentres.2021.vol11.no3.3
1 - 35 of 35 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information