Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Finite elements analysis of stresses formed in core and spongious bone tissue by restored implanted fixed prostheses with Polyetheretherketone (PEEK) and fiber-reinforced composite

    Aim: This study uses the finite element analysis method to compare the effects of different abutments and prosthetic materials on stress distribution in the rehabilitation of maxillary anterior tooth deficiencies with fixed implanted prostheses. Methodology: In our study, two titanium implant models with a diameter of 4.1 mm and a length of 10 mm were designed for the maxillary central and canine teeth regions. 3D models of the prosthetic restorations were created with PEEK and fiber-reinforced composite and two different abutment materials (titanium and zirconia). After meshing the materials used with cortical and cancellous bone, Poisson ratio and young module values were loaded into the program. Maxillary central and canine to the palatal surface of the tooth, 2 mm below the incisal edge; a 178 N force was applied in both the vertical and 45° oblique directions, and analysis was performed. The distributions of the highest compression and tensile stress values in peri-implant cortical and cancellous bone were examined, and the results were compared. Results: Material with low elastic modulus caused higher stress accumulation in the cortical and cancellous bone tissue around the implant during oblique force application. In all study groups, the maximum stress values ​​observed in the cancellous and cortical bone during oblique force application were significantly higher than those observed during vertical force application. Thus, different prosthetic materials had different effects on stress distribution in peri-implant cortical and cancellous bone tissue, and the highest stress accumulations were in the peri-implant cortical bone. Conclusion: Different prosthetic materials had different effects on stress distribution in peri-implant cortical and cancellous bone tissue.   How to cite this article: Çelik H, Zengingül Aİ, Göncü Başaran E. Finite elements analysis of stresses formed in core and spongious bone tissue by restored implanted fixed prostheses with Polyetheretherketone (PEEK) and fiber-reinforced composite. Int Dent Res 2021;11(Suppl.1):250-8. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.37     Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Polyetheretherketone, PEEK composite, fiber-reinforced composite, finite element stress analysis, dental implant
    Hidayet Çelik, Emine Göncü Başaran, Ali İhsan Zengingül
    30.09.2021
    250-258
    Abstract Views: 2028 Download: 488 DOI 10.5577/intdentres.2021.vol11.suppl1.37
  • Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength

    Aim: In this in vitro study, the effect of two adhesive systems applied to surfaces of different polyether-ether-ketone (PEEK) composites on the shear bond strength (SBS) of a composite resin was compared. Methodology: Eighty PEEK specimens were divided into four groups (n=20): Unfilled PEEK (UF), carbon-fiber-reinforced PEEK (CFR), glass-fiber-reinforced PEEK (GFR), and ceramic-reinforced PEEK (CR). Each group was further divided into two subgroups (n=10): Visio.link (VL) and Single Bond Universal (SB). The specimens with 8-mm diameter and 5-mm thickness were prepared. SBS was examined using a universal testing machine. Results were statistically analyzed by multivariate analysis of variance and Tukey’s post-hoc test. Failure modes were analyzed using a stereomicroscope at 20× magnification. Surface properties were examined by scanning electron microscopy. The surface properties of the specimens were examined by scanning electron microscopy (SEM).  Results: Effect of different PEEK and adhesive systems on SBS was found to be statistically significant (p<0.05). SBS values for CFR-VL and UF-VL groups were statistically more significant than those for CFR-SB and UF-SB groups (p=0.001). SBS values for the GFR-VL group were statistically more significant than that for the UF-VL group (p=0.001). SBS values for the CF-SB group were statistically more significant than those for CFR-SB and CFR-SB groups (p=0.001). Failure modes were examined using a stereomicroscope at 20× magnification, and adhesive and mixed failure modes were observed. Conclusion: PEEK composites with different contents and properties can be used in fixed prosthetic restorations. However, additional experimental and clinical studies are required to investigate different PEEK frameworks and composite veneers.   How to cite this article: Demirci F, Tekin S. Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength. Int Dent Res 2021;11(2):54-61. https://doi.org/10.5577/intdentres.2021.vol11.no2.1   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    adhesion, PEEK, PEEK composites, Polyetheretherketone, shear bond strength, veneering
    Fatih Demirci, Samet Tekin
    31.08.2021
    54-61
    Abstract Views: 1866 Download: 1136 DOI 10.5577/intdentres.2021.vol11.no2.1
  • Use of novel polyetheretherketone (PEEK) polymer in pediatric dentistry

    The purpose of this study is to discuss the applications of PEEK in pediatric dentistry and the advantages of PEEK material in terms of periodontal health. In pediatric dentistry, there is a continuous search for biocompatible, esthetic, and durable materials to overcome the limitations of conventional options such as stainless steel and zirconia. Polyetheretherketone (PEEK), a high-performance semicrystalline polymer, has emerged as a novel alternative due to its superior mechanical properties, resistance to heat and chemicals, and an elastic modulus comparable to human bone. This review aims to evaluate the material characteristics of PEEK, its impact on periodontal health, and its clinical applications within pediatric dentistry. PEEK is amenable to digitalization and can be fabricated using CAD/CAM milling and 3D printing, ensuring precise fit and patient comfort. In pediatric orthodontics and space maintenance, PEEK serves as an esthetic, metal-free alternative, eliminating risks of nickel allergy while providing high strength and significantly reduced weight compared to traditional appliances. For restorative procedures, PEEK is utilized in crowns, endocrowns, and post-core systems. Its shock-absorbing capability allows for favorable stress distribution in dentin, reducing the risk of root fractures often associated with rigid materials like metal or glass fibers. Additionally, its low specific gravity and biocompatibility make it an effective material for obturators in treating cleft lip and palate defects. Regarding periodontal health, polished PEEK surfaces demonstrate low plaque affinity and acceptable surface roughness, supporting gingival health. PEEK offers distinct advantages in pediatric dentistry, particularly for patients requiring metal-free, lightweight, and shock-absorbing restorations. While it presents a promising alternative to traditional materials, achieving durable adhesion requires specific surface treatments, and further prospective clinical studies are warranted to validate its long-term performance.
    PEEK, pediatric dentistry, space maintainers, biocompatibility, CAD/CAM, periodontal health, dental application
    Semih Ercan Akgün, Şemsettin Yıldız, Samet Tekin
    31.08.2025
    85-91
    Abstract Views: 1697 Download: 572 DOI 10.5577/intdentres.486
  • An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study

    Aim: Metal-supported ceramics as crown material and glass fiber posts as dental post materials are in frequent current use. In recent years, it has been claimed that stress-based biomechanical problems in dentistry can be resolved with the benefit of the low elasticity modulus of polyetheretherketone (PEEK) material. The aim of this study was to use finite element analysis (FEA) to compare the stresses formed by forces applied after the use of PEEK material as dental post and crown material as an alternative to glass fiber posts and metal-supported ceramic crowns. Methodology: The stress analysis method used in this study was FEA. First, micro-computed tomography (micro-CT) images were obtained of a maxillary central incisor tooth and the data of the post materials scanned with a 3-dimensional (3D) laser scanner were uploaded to a computer program. 3D models were obtained with designs made in the computer program of all the materials. The modelling of a maxillary central tooth was completed using 2 different post materials (glass fiber and PEEK) and 2 different crown materials (metal ceramic and PEEK) and 4 groups were formed for analysis. By applying force of 100 N at 135 o from the absolute central point of the palatinal surface of the tooth, the stress values and distribution occurring in the 3D periodontal models were compared. Results: The use of PEEK post reduced the stresses occurring on the periodontal ligament (PDL) and the cortical bone, and caused no significant change in the stresses on the crown. The use of PEEK crown reduced the stresses occurring on the crown and increased the stresses occurring on the PDL and cortical bone. Conclusions: With further in vitro and clinical studies of PEEK material, it can be considered that within a short time PEEK post and PEEK crown could be in routine use in dentistry.   How to cite this article:  Tekin S, Adıgüzel Ö, Cangül S. An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study. Int Dent Res 2018;8(3):144-50.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Polyetheretherketone, PEEK post, glass fiber post, PEEK crown, finite element analysis, micro-CT
    Samet Tekin, Özkan Adıgüzel, Suzan Cangül
    30.12.2018
    144-150
    Abstract Views: 4697 Download: 1137 DOI 10.5577/intdentres.2018.vol8.no3.8
  • Areas for use of PEEK material in dentistry

    Polyetheretherketone (PEEK) material is a polycyclic, aromatic, thermoplastic polymer that is semi-crystalline and has a linear structure. PEEK has good mechanical and electrical properties such as resistance to high temperature and resistance to hydrolysis. In addition, because of the property of high biocompatibility, use of PEEK has increased in orthopedic and trauma cases. The most characteristic property of PEEK material is that it has a low elasticity modulus, close to that of bone. It has been suggested that stress-based problems could be reduced with this material due to the low elasticity modulus. In the light of this information, PEEK material could be considered as an alternative to conventional materials in the field of dentistry.   How to cite this article: Tekin S, Cangül S, Adıgüzel Ö, Değer Y. Areas for use of PEEK material in dentistry. Int Dent Res 2018;8(2):84-92.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Polyetheretherketone, PEEK, polymer, dental application, dental implant
    Samet Tekin, Suzan Cangül, Özkan Adıgüzel, Yalçın Değer
    27.08.2018
    84-92
    Abstract Views: 9560 Download: 15128 DOI 10.5577/intdentres.2018.vol8.no2.6
  • Comparison of marginal adaptation and fracture strength of PEEK endocrown restorations fabricated using additive and subtractive methods

    Aim: The aim of this in vitro study was to compare the marginal fit and fracture strength of endocrown restorations applied to maxillary canines, using different manufacturing methods. Methodology: An extracted upper canine tooth was prepared for endocrown placement. Three methods were used to create the endocrowns: Fused Deposition Modeling (FDM) 3D printing with Essentium Polyetheretherketone (PEEK) filament, CAD/CAM milling with Juvara PEEK disk, and SLS 3D printing with Cr-Co metal (N=10). Additionally, 30 identical canine tooth replicas were produced using an Asiga 3D printer with a model resin, and the crown restorations were cemented with a resin luting cement. Fracture strengths were tested, and marginal fits were evaluated using Geomagic Control X software. Statistical analysis was performed, and Weibull analysis was used to assess fracture strength values. Results: The laser-sintered endocrowns exhibited higher fracture strength (1351 N) compared to PEEK FDM (735.341 N) and milled PEEK (826.733 N) endocrowns. The highest Weibull modulus was found for milled PEEK (3.978), while the lowest was for the Cr-Co laser-sintered material (2.912). A significant difference in marginal fit was observed on the palatal surface of the PEEK FDM group compared to the other two groups (p=0.048). However, no significant differences were found on the mesial, distal, or buccal surfaces. Conclusion: The findings indicate that PEEK endocrowns produced by FDM and milling offer clinically acceptable fracture strength and marginal fit, with PEEK being closer to the dentin elastic modulus. The significantly higher Weibull modulus of PEEK endocrowns produced by the FDM Printer and milling enables us to make more accurate intraoral fracture predictions.
    Endocrown, PEEK, FDM, fracture strength, milling, Weibull analysis
    Ayşe Rençber Kızılkaya, Oğuzhan Kaya, Aybüke Kara, Eyyüp Altıntaş, Samet Tekin
    31.08.2025
    45-52
    Abstract Views: 1160 Download: 497 DOI 10.5577/intdentres.628
1 - 6 of 6 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information