Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Evaluation of ProTaper Ultimate, ProTaper Next, and ProTaper Gold system instruments for debris and irrigant extrusion

    Aim: The aim of this investigation was to compare recently released ProTaper Ultimate system (PTU) instruments, ProTaper Next (PTN), and ProTaper Gold (PTG) in terms of apically extruded debris and irrigant. Methodology: Forty-five human extracted mandibular molar teeth had their mesial roots decoronated. The roots were then split into three groups (n = 15) for the root canal preparation system: PTU, PTG, and PTN. Using the Myers and Montgomery technique, the roots were embedded in the experimental apparatus to collect and analyze the extruded material. The root canals were prepared according to the manufacturer's instructions. The weights of the extruded debris and irrigant were analyzed using ANOVA with post hoc Tukey tests to evaluate the level of significance (p < 0.05). Results: The PTU group produced the least amount of irrigant and debris. The amount of extruded irrigant produced by each group was statistically significantly comparable (p > 0.05). PTU produced lower debris weight than PTG in terms of debris extrusion (p < 0.05). For apically extruded debris, no statistically significant differences were observed among the other comparison pairs (p > 0.05). Conclusion: For apically extruded irrigant extrusion, the investigated instrument systems produced comparable results. Similar to PTG, the recently introduced PTU method showed promising findings.
    Irrigant extrusion, debris, rotary instruments, nickel-titanium, ProTaper Ultimate, ProTaper Next, ProTaper Gold
    Esma Sarıçam, Sümeyye Türker Konukman
    31.12.2025
    153-158
    Abstract Views: 609 Download: 235 DOI 10.5577/intdentres.614
  • Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion

    Aim: The aim of this study is to evaluate the amount of debris extruded apically by the primary shaping files of three rotary file systems manufactured with different alloy technologies [TruNatomy (TRN), ProTaper Ultimate (PTUltimate), and VDW.Rotate (VDW.R) files]. Methodology: Thirty lower premolar teeth with moderate curvature (10-20°) were randomly divided into three equal groups (n=10) according to three rotary file systems [TRN (26.04v), PTUltimate (25.08v), and VDW.R (25.06v)]. The debris extruded apically was collected in Eppendorf tubes of known weights. After preparation, the tubes were placed in an incubator at 70°C for five days to evaporate the distilled water. The tubes filled with debris were then weighed again, and the net weight of the extruded debris was calculated in grams (g) by subtracting the initial weight from the final weight. The data were analyzed using one-way ANOVA test. Results: There was no significant difference in the amount of debris extruded apically by the three shaping files ( p > 0.05). The highest amount of debris extruded apically was 0.9534 g for PTUltimate. VDW.R extruded the minimum amount of debris apically, with 0.1833 g. Conclusion: All rotary files have caused apical debris extrusion. Even though there was no significant difference among the files, the VDW.R file extruded less debris compared to other file systems.   How to cite this article: Eskibağlar M, Yeniçeri Özata M, Timis Ll. Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion. Int Dent Res 2023;13(S1):26-31. https://doi.org/10.5577/idr.2023.vol13.s1.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Apically extruded debris, nickel-titanium file, root canal preparation, ProTaper Ultimate, TruNatomy, VDW.Rotate
    Mehmet Eskibağlar, Merve Yeniçeri Özata, Lucia lacobina Timis
    15.10.2023
    26-31
    Abstract Views: 4904 Download: 1361 DOI 10.5577/idr.2023.vol13.s1.4
  • Comparative evaluation of the dimensional compatibility of ISO #30/.06 gutta-percha cones from four different manufacturers using an endodontic gauge

    Aim: Gutta-percha is the most commonly used biocompatible obturation material in endodontics for the three-dimensional and hermetic sealing of the root canal system. However, despite the dimensions defined in the ISO 6877 standard, dimensional discrepancies between gutta-percha cones and endodontic files have been reported. The aim of this study was to comparatively evaluate the dimensional variability of ISO #30/.06 gutta-percha cones from four different manufacturers using an endodontic gauge. Methodology: A total of 240 ISO #30/.06 gutta-percha cones (n = 60 per brand) from four manufacturers (ProTaper Ultimate, MetaBiomed, Diadent, and EndoArt) were evaluated. Cone diameters were measured at the D0, D5, D10, and D15 levels using a Woodpecker R1 Plus endodontic gauge. Based on the ISO 6877 nominal dimensions, measurements were categorized as undersized, within the nominal range, or oversized. Statistical analysis was performed using Pearson's chi-square and Fisher's exact tests with Bonferroni correction (p < 0.05). Results: Dimensional discrepancies from the nominal ISO values were observed across all measurement levels, with statistically significant differences among the brands (p < 0.05). ProTaper Ultimate and MetaBiomed showed the highest compatibility with nominal dimensions, whereas EndoArt exhibited a consistently high proportion of undersized cones (57.1–67.2%) across all regions. Diadent showed a notably high proportion of oversized cones at the D15 level (66.7%). Effect sizes for between-brand comparisons were large at every level (Cramer's V = 0.386–0.503). Conclusion: ISO #30/.06 gutta-percha cones from different manufacturers did not show complete dimensional compatibility. These discrepancies may adversely affect apical adaptation, particularly in single-cone obturation techniques, potentially reducing clinical success. The use of an endodontic gauge provides a practical means of objectively verifying cone–canal adaptation in clinical practice, helping to prevent microleakage and obturation errors.
    Gutta-percha, endodontic gauge, dimensional compatibility, root canal treatment, dimensional accuracy, ISO 6877, root canal obturation
    Kumru Şaz, Hülya Nur Nalbant, Celalettin Topbaş
    11.07.2026
    e260664
    Abstract Views: 505 Download: 157 DOI 10.5577/intdentres.664
1 - 3 of 3 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information