Search
Search Results
##search.searchResults.foundPlural##
-
Evaluation of dentinal micro-cracks caused by the ProTaper Universal, ProTaper Next and Reciproc rotary file systems used in root canal preparation
Objective: In this study, we compared the occurrence of dentinal micro-cracks after use of the ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), and Reciproc (VDW, Munich, Germany) nickel–titanium rotary file systems in root canal preparation. Method: One hundred mandibular anterior teeth were divided into five groups of 20 specimens each. Group 1 served as a control, with no intervention. In group 2, preparation was performed using the step-back technique and K files. In groups 3–5, root canal preparation was performed using the ProTaper Universal, ProTaper Next, and Reciproc file systems, respectively. Following preparation, specimens were sectioned at 3, 6, and 9 mm using a Minitom precision cut-off machine. The sections were evaluated under a stereomicroscope. The following scoring system was used to rate specimens: 1, no micro-crack; 2, incomplete micro-crack; and 3, vertical root fracture. The results were statistically assessed ( p ≤ 0.05). Results: No micro-crack formation was observed in groups 1 and 2. The highest rate of micro-crack formation was observed in specimens prepared with the ProTaper Universal file system (20%), followed by those prepared with the Reciproc (11.7%) and ProTaper Next (6.7%) file systems. However, no significant difference was detected among groups ( p > 0.05). In the groups ProTaper Universal and Reciproc files were used, 1 vertical root fracture was found in 9 mm sections for each. Conclusion: Considering the limitations of in vitro studies, we can conclude that all rotary file systems used in this study led to dentinal micro-crack formation in roots. The ProTaper Universal file system caused more dentinal micro-cracking than did the ProTaper Next and Reciproc file systems. How to cite this article: Deveci Taç M, Kaya S, Falakaloğlu S. Evaluation of dentinal micro-cracks caused by the ProTaper Universal, ProTaper Next and Reciproc rotary file systems used in root canal preparation. Int Dent Res 2018;8(3):111-16. Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Micro-crack, ProTaper Universal, Reciproc, ProTaper NextMeltem Deveci Taç, Sadullah Kaya, Seda Falakaloğlu30.12.2018111-116 -
The comparison of cyclic fatigue resistance of two different reciprocal files according to different access angles into the root canal
Aim: Root canal preparation is one of the most important steps of root canal treatment. Preparation procedure includes disinfection and shaping protocols. Ni-Ti rotary file systems are usually used for shaping. The biggest disadvantage of the usage of Ni-Ti rotary file systems is that the file gets broken during the treatment. There are many reasons for the breakage of files. One of the reasons may be the increase in the access angle. The purpose of this study is to compare the cyclic fatigue of reciprocating Reciproc and WaveOne Gold rotary systems according to different angles of accessing the root canal of Ni-Ti files. Methodology: In our study, 90 root canal files were used, 45 of which is Reciproc R25 (VDW GmbH, Munich, Germany) and the other 45 of which is WaveOne Gold Primary 25/07 (Dentsply, Maillefer, Ballaigues, Switzerland). Specially designed and manufactured stainless steel artificial roots whose curvature angle is 60° and curvature radius is 5 mm, which replicates the clinical conditions, were arranged. By enabling the files access the roots at 0°- 15°- 30° degrees, the lap numbers that they do till they break due to cyclic fatigue were examined. Results: When looking at the lap numbers that the Reciproc and WaveOne Gold root canal files do till they break, at accessing the roots at the same angles WaveOne Gold root canal file makes more lap numbers at all angles when compared with the Reciproc root canal file. Significant results were found when the groups were compared within one another and between groups and among all numeric data in the statistical analysis performed. It was also found that WaveOne Gold root canal file had more cyclic fatigue resistance. When the groups were compared within one another, it was found that the increase in the root access angle decreases the cyclic fatigue resistance of the files (p<0.05). No significant difference was found in the statistical analysis for comparison of the length of the broken file pieces (p=0.01). It was analyzed that when the broken files were examined via scanning electron microscope, file breakages occurred due to cyclic fatigue. Conclusion: Not only do the design features and production technology affect the breakage resistance due to cyclic fatigue of the root canal, the access angle to the roots affects the cyclic fatigue of the root canal files, as well. How to cite this article: Adıgüzel Ö, Dundar M, Kaya S. The comparison of cyclic fatigue resistance of two different reciprocal files according to different entry angles into the root canal. Int Dent Res 2021;11(Suppl.1):114-21. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.18 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.cyclic fatigue, Reciproc, WaveOne Gold, reciprocating motion, access angle, static test modelMehmet Dundar, Özkan Adıgüzel, Sadullah Kaya30.09.2021114-121 -
Root canal cleaning with different reciprocating and rotary instrumentation systems
Aim: The purpose of the present study was to compare the cleaning effectiveness of two reciprocating single-file systems with ProTaper Next and ProTaper Universal rotary instruments during the preparation of single-rooted extracted teeth. Methodology: Sixty freshly extracted single-rooted human teeth were randomly divided into 4 groups (n=15). In group 1, root canals were prepared with ProTaper Universal, in group 2, they were prepared with ProTaper Next, in group 3, they were prepared with WaveOne and in group 4, root canals prepared with Reciproc systems. Canals were prepared to the following apical sizes: ProTaper Universal F3, ProTaper Next X3, WaveOne Primary and Reciproc 25. The irrigant in all groups was 2ml 2.5% sodium hypochlorite (NaOCl) solution, the final irrigation after preparation all groups was 2ml NaOCl, 2ml EDTA and 2ml saline solution. The roots were split longitudinally into halves and the canals examined using a scanning electron microscope. The presence of a debris and smear layer was recorded at the coronal, middle and the apical thirds of root canals using a five-step scoring scale. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: All groups showed more efficient smear layer and debris removal coronally than in the middle and apical regions, whereas the mean total debris score and the mean smear layer score in all groups were less in the WaveOne and the Reciproc groups. Conclusions: Under the conditions of this study, for root canal cleanliness Reciproc and WaveOne may be preferred rather than ProTaperUniversal and ProTaperNext. How to cite this article: İnce Yusufoğlu S, Arı Aydınbelge H. Root canal cleaning with different reciprocating and rotary instrumentation systems. Int Dent Res 2019;9(1):1-8. Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Debris, ProTaper Next, Reciproc, WaveOne, SEMSelen İnce Yusufoğlu, Hale Arı Aydınbelge30.04.20191-8 -
Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles
Aim: To compare the amount of apically extruded debris using Reciproc (R25) file with different reciprocal angles. Methodology: In this research, 60 extracted mandibular premolars with a single root, a single canal, and a single apical foramen were used. Specimens, the working length of which was determined by a stainless steel 10-K file, were randomly distributed into three experimental groups (n = 20) as follows: Group 1 150° counterclockwise (CCW)-30° clockwise (CW); Group 2 180° CCW-60° CW; and Group 3 210° CCW-90° CW. For the irrigation, 10 mL of distilled water was administered via syringe pump. The extruded debris was collected into Eppendorf tubes tared in advance. The distribution of data was analyzed using a Shapiro-Wilk test. A Kruskal-Wallis H test was used for statistical analysis. The null hypothesis is no significant difference between the groups in terms of the amount of apical extrusion of debris. Results: There was no statistically significant difference between the groups with regard to amount of apical extrusion of debris (p>0.05). Nevertheless, the highest average amount of extrusion of debris was detected in group 1, and the lowest in group 3. Conclusion: According to the results of this study, different reciprocal angles during chemomechanical preparation has no significant effect on the amount of apical extrusion of debris. How to cite this article: Çelik N, Kaya S, Adıgüzel Ö. Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles. Int Dent Res 2021;11(Suppl.1):63-6. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.10 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Reciproc, kinematics, reciprocation, debris extrusionNezif Çelik, Sadullah Kaya, Özkan Adıgüzel30.09.202163-66 -
Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation
Aim: The purpose of this in vitro study is to compare the cyclic fatigue resistance of Reciproc Nickel-Titanium (Ni-Ti) rotary files while operating root canals using in three different reciprocal angles. Methodology: Forty-five pieces of Reciproc R25 canal files were tested using artificial canals with a 60° angle of curvature, 5 mm curvature radius, and 1.5 mm diameter carved into a stainless steel block. The Ni-Ti files were checked with a stereomicroscope and then randomly separated into 3 groups. Group 1 consisted of reciprocal angles CCW 150°–CW 30°, Group 2 consisted of CCW 180°–CW 60°, and Group 3 consisted of CCW 210°–CW 90°. The duration of the cyclic fatigue being measured, elapsed time until a file fractured was determined with a chronometer. The lengths of the fractured pieces were measured with a digital caliper. After the cyclic fatigue test, two samples from each group were examined with a Scanning Electron Microscope (SEM) to determine the signs of cyclic fatigue. Results: One-way analysis of variance (ANOVA) was applied to the normally distributed groups (p<0,05). Since there was a significant statistical difference of file’s cyclic fatigue resistance (p=0,001) between the groups, Tukey’s honestly significant difference (HSD) post-hoc pairwise comparison test were used for determine to between which groups. While there were statistically significant differences between Group 1 and Group 2 (p=0,001), and between Group 1 and Group 3 (p=0,001), there was no significant difference between Group 2 and Group 3 (p=0,376). Group 1 displayed the highest resistance to cyclic fatigue. There were no statistically significant differences between the lengths of the fractured files within the three groups according to the one-way analysis of variance (p=0,847). Conclusion: In our study, it was observed that the reciprocal angles of CCW 150°–CW 30°, which were also suggested by the file manufacturer firms, had the highest fracture resistance against cyclic fatigue. How to cite this article: Akay A, Adıgüzel Ö, Erkan Akay S, Kaya S. Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation. Int Dent Res 2021;11(Suppl.1):67-72. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.11 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.cyclic fatigue, reciprocal movement, kinematics, reciproc fileAhmet Akay, Özkan Adıgüzel, Seda Erkan Akay, Sadullah Kaya30.09.202167-73 -
Efficacy of passive ultrasonic activation and photon-initiated photoacoustic streaming on apical extruded debris of different rotary systems in curved canals
Aim: The aim of this study was to investigate the impact of photon-initiated photoacoustic streaming (PIPS) and ultrasonic activator Ultra X (UX) on the extrusion of debris using the One Curve (OC) rotary system and the Reciproc Blue (RB) system in curved canals. Methodology: Ninety extracted mandibular first molar teeth were divided into six groups (n = 15), Group (1): OC with PIPS, (2) OC with UX, (3) OC with conventional needle irrigation (CNI), (4) RB with PIPS, (5) RB with UX, and (6) RB with CNI. The irrigation activation methods were used in the final irrigation with 2.5 cc of distilled water. The apically protruded debris was collected into pre-weighed Eppendorf tubes. By deducting the tube's initial weight from the final weight, the weight of dry protruded debris was calculated. Two-way ANOVA test was used to analyze the results statistically. Results: A significant difference was found among all groups ( p < 0.05). No statistically significant difference was found among the instrumentation systems, regardless of the irrigation technique employed ( p > 0.05). The statistically significant difference was found among the PIPS, UX, and CNI irrigation systems, regardless of the rotary systems ( p < 0.05). CNI caused significantly less debris extrusion than the UX ultrasonic irrigation activation systems. Conclusion: The UX irrigation activation system caused the highest amount of debris extrusion in curved canals. PIPS can be preferred to ultrasonic devices as irrigation activation systems. How to cite this article: Akman M, Bozkurt DA, Zogheib C. Efficacy of passive ultrasonic activation and photon-initiated photoacoustic streaming on apical extruded debris of different rotary systems in curved canals. Int Dent Res 2023;13(1):13-18. https://doi.org/10.5577/idr.2023.vol13.no1.3 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Apical debris extrusion, PIPS, laser-activated irrigation, ultrasonic activation, Reciproc Blue, One CurveMelek Akman, Durmuş Alperen Bozkurt, Carla Zogheib30.04.202313-18 -
The Effects of Antioxidant Application and Time Factor on Fiber Post Bonding to Root Dentin after Intracoronal Bleaching
Aim: The aim was to evaluate the effects of antioxidant application and delayed cementation on the bond strength of fiber posts after intracoronal bleaching. Methodology: Fifty-five maxillary central incisors were used. Root canals were enlarged using Reciproc system up to R40 instrument. Root canals were irrigated, dried with paper-points, and obturated with gutta-percha and a sealer. In 44 teeth, root canal fillings were removed 2-mm coronally and canal orificies were sealed with glass-ionomer-cement. A 37% CP gel was used to bleach the teeth. Five experimental groups were defined (n=11). G1: No bleaching, G2: Immediate FPC, G3: Immediate FPC after SA application, G4: 14-days delayed FPC, G5: 14-days delayed FPC after SA application. Push-out tests were performed. Statistical interpretations were made (α=0.05). Results: There was no significant difference among the groups in apical thirds (p>0.05). However, significant differences were detected among the groups in middle and coronal thirds (p<0.05). Conclusion: The 14-days delayed cementation seems to be a more reliable method than the SA application before FPC procedure after intracoronal bleaching. How to cite this article: Aslan T, Üstün Y, Sağsen B, Şener İ, Biricik E, Tatlı Ş. The effects of antioxidant application and time factor on fiber post bonding to root dentin after intracoronal bleaching. Int Dent Res 2018;8(1):22-7. Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Internal bleaching, devital bleaching, antioxidant application, sodium ascorbate, delayed cementation, push-outTuğrul Aslan, Yakup Üstün, Burak Sağsen, İbrahim Şener, Eda Biricik, Şifa Tatlı30.04.201822-27 -
The effect of different final irrigation solutions on apical impermeability
Aim: This study aimed to compare ethylenediaminetetraacetic acid (EDTA), phytic acid, and citric acid as chelation agents in final irrigation procedures on teeth with apical impermeability. Methodology: We used 66 mandibular premolar teeth with a single root and single canal extracted for periodontal or orthodontic reasons. All teeth crowns were removed to achieve a 14-mm root length. Mechanical preparation of the root canal was completed with a Reciproc R25 (VDW, Munich, Germany) file system. Teeth were randomly separated into three groups: Group 1: 5 ml 17% EDTA, Group 2: 5 ml 1% phytic acid, and Group 3: 5 ml 20% citric acid. We used 6 ml 5.25% sodium hypochlorite (NaOCl) in the mechanical preparation of all groups. Three teeth were selected for both the positive and negative control groups. All teeth in the experimental groups were filled by the lateral condensation method using AH Plus canal sealer and gutta-percha. For hardening of the canal sealer, samples were kept at 37 oC and at 100% humidity in a drying oven for 7 days. Later, following removal from the drying oven, two layers of nail polish were used to cover all but the apical 2 mm of each tooth. The teeth were then kept in 2% methylene blue solution at 37 oC for 7 days. The root was divided by cutting in the buccolingual direction and gutta-percha was removed. The dye leakage was measured linearly in millimeters (mm) under a stereomicroscope. Results: As a result of the apical leakage assessment, the lowest apical leakage is observed in the phytic acid group. There was a statistically significant difference between the phytic acid group and citric acid group. There was no statistically significant difference between other groups. Conclusion: While phytic acid showed similar results with EDTA on apical impermeability, it was more effective than citric acid. How to cite this article: Akın Tartuk G, Kaya S, Adıgüzel Ö. The effect of different final irrigation solutions on apical impermeability. Int Dent Res 2021;11(Suppl.1):201-5. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.28 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.microleakage, EDTA, phytic acid, dye penetration testGizem Akın Tartuk, Sadullah Kaya, Özkan Adıgüzel30.09.2021201-205 -
Comparison of the accuracy of three different electronic apex locators used in root canals enlarged in different apical diameters
Aim: This study aimed to evaluate the accuracy of three apex locators in enlarged teeth with different apical diameters using files that are compatible and incompatible with the apical diameters. Methodology: Sixty lower premolars were used in this study. The actual canal length was determined with a stereo microscope, and the teeth were divided into three different groups (G25, G40 and G50). The teeth in G25, G40 and G50 were enlarged in actual canal length with apical diameters of 0.25, 0.40 and 0.50 mm using hand files and Reciproc R25, R40, and R50, respectively. In the electronic measurements, a #15 hand file was used in each group, and #25, #40 and #50 hand files that were compatible with the apical diameters of the teeth in the groups were used. An alginate model was created with enlarged teeth. The electronic working length was determined for each tooth using Root ZX Mini, Raypex 6, and Propex Pixi electronic apex locators (EALs). Results: Electronic measurement results that were shorter by 0.50 mm or longer by 0.05 mm than the actual length were considered unsuccessful; otherwise, they were deemed successful. Analysis of variance was used to evaluate the accuracy of the EALs with different files in the same apical diameter. For the different apical diameters, the chi-square exact test was used to evaluate the accuracy effect of using files that were incompatible with each apical diameter. The level of significance was p > 0.05. In all the groups, the measured lengths were closer to the actual canal length with the use of #25, #40 and #50 hand files that were compatible with the apical diameters. However, there was no significant difference between the measurements with the #15 hand file (p > 0.05). According to the electronic measurement results made with the #15 hand file in teeth with 0.25, 0.40 and 0.50 apical diameters, the use of a file that was incompatible with the apical diameter did not have a significant effect on accuracy (p > 0.05). Conclusion: The use of a file that is compatible with the apical diameter of the tooth in the determination of the working length with measurement of EALs close to the actual canal length. The accuracy of EALs is not affected by the file size in electronic measurements with file sizes smaller than the apical diameter in teeth with apical diameters up to 0.50 mm. How to cite this article: Öz H, Adıgüzel Ö, Kaya S. Comparison of the accuracy of three different electronic apex locators used in root canals enlarged in different apical diameters. Int Dent Res 2021;11(Suppl.1):12-8. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.3 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.electronic apex locator, apical constriction, apical diameterHasan Öz, Özkan Adıgüzel, Sadullah Kaya30.09.202112-18 -
Evaluation of the effectiveness of reciprocal and conventional shaping systems and EDDY and CanalBrush activation systems in calcium hydroxide removal
Aim: To compare the effectiveness of two preparation systems and two irrigation techniques in calcium hydroxide removal from straight root canals. Methodology: Forty-four mandibular premolar teeth were included in this study. The teeth were filled with a calcium hydroxide-based paste and randomly divided into two different preparation groups (Reciproc 50 (R50; VDW, Munich, Germany and ProTaper Universal F5 (PTU; Dentsply Maillefer, Ballaigues, Switzerland). Subsequently, the groups were divided into two subgroups and irrigated using EDDY (VDW, Munich, Germany) and CanalBrush (CB; Roeko, Langenau, Germany) irrigation activation systems. The percentage of calcium hydroxide removed from the canal walls was analyzed using a dental operating microscope (DOM) at 25× magnification. An independent samples t -test, a Mann–Whitney U, Wilcoxon’s tests were used for statistical analysis. Results: There was no significant difference in calcium hydroxide removal throughout the root canal using the R50 and PTU F5 preparation systems ( P = 0.847). Both activation systems significantly increased the amount of calcium hydroxide removed from the root canal. Conclusions: EDDY and CB significantly improved calcium hydroxide removal. There was no significant difference between the R50 and PTU F5 systems in calcium hydroxide removal. How to cite this article: Keskin NB, İnce Yusufoğlu S. Evaluation of the effectiveness of reciprocal and conventional shaping systems and EDDY and CanalBrush activation systems in calcium hydroxide removal. Int Dent Res 2021;11(1):16-22. https://doi.org/10.5577/intdentres.2021.vol11.no1.4 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.Calcium hydroxide, CanalBrush, EDDY, Reciproc, root canal dressingNeslihan Büşra Keskin, Selen İnce Yusufoğlu30.04.202116-22
1 - 10 of 10 items


















Open Access articles are distributed under the terms of the