Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Comparison of the effect of different rapid maxillary expansion treatments on tooth hardness values: Splint mouth study

    Aim: The purpose of this study, planned as a splint mouth design, is to compare the effects of different rapid maxillary expansion (RME) appliances on the hardness values of teeth. Methodology: This study utilized extracted upper first premolar teeth from a previous study conducted by Yıldırım and Akın in 2019 on 20 patients. Five patients were excluded from this study due to fractures of the tooth crown during extraction, which also necessitated the exclusion of the opposing arch teeth. The extracted teeth were stored in distilled water at +4 degrees Celsius. The crowns and roots of these teeth were separated at the cementoenamel junction using an aerator and a diamond bur under water cooling. The crowns were then embedded into rings of standard thickness using the cold acrylic dripping method. Hardness measurements were performed using a Vickers Hardness tester. Enamel samples obtained from the patients were placed under a test microscope and examined at X40 magnification; force was applied to each enamel sample for 10 s. The device automatically calculated and recorded the microhardness value relationship. The Shapiro-Wilk test was used to confirm the normal distribution of the data. Comparisons between groups were conducted using Student's t-test. Results: The group using the hybrid maxillary expansion appliance showed lower hardness values than the conventional group, although the difference was not statistically significant. Conclusion: Fixed orthodontic treatments similarly increase the demineralization of teeth. Therefore, individual or preventive measures by dentists or orthodontists should be taken against mineral losses.   How to cite this article: Sağoğlu S, Yıldırım M, Akın M, Erdur EA. Comparison of the effect of different rapid maxillary expansion treatments on tooth hardness values: Splint mouth study. Int Dent Res. 2024;14(S1):45-49. https://doi.org/10.5577/indentres.564
    Hardness test, rapid maxillary expansion, splint mouth design, tooth extraction, hardness
    Seda Sağoğlu, Mücahid Yıldırım, Mehmet Akın, Emire Aybüke Erdur
    31.12.2024
    45-49
    Abstract Views: 2114 Download: 474 DOI 10.5577/indentres.564
  • A comparative study of the 5 mm-layer Vickers hardness model with bulk-fill resin-based composites

    Aim: The aim of this study was to compare the Vickers hardness numbers (VHNs) of two bulk-fill resin-based composites (BFRBC) and a conventional hybrid resin-based composite (RBC) through the layers of a 5mm thickness model with two different light-curing time intervals. Methodology: In the present study, a sonic-activated and dual-cure BFRBC, and a conventional hybrid RBC were used. Semi-cylindrical specimens 4 mm in radius and 5 mm in height were prepared using a two-piece stainless-steel mold (n=10). The BFRBCs allowed a single 5mm increment to be introduced into the molds, whereas hybrid RBC was incremented (2+2+1 mm). Two different time intervals were applied for the light-curing (irradiance of 1200 mW/cm 2 ) of each material (hybrid-sonic-activated bulk-fill, 20 s and 40 s; dual-cure bulk-fill, 7 s and 15 s). VHN measurements were carried out from top to bottom at every 1 mm of the specimen thickness. Data were analyzed using three-way and two-way ANOVA for the VHN and bottom/top ratios and Bonferroni correction for multiple comparisons (p=0.05). Results: For each layer and time interval groups, there was a significant difference between the materials. The highest VHN was found within hybrid groups, whereas dual-cure bulk-fill groups showed the lowest results. Sonic-activated bulk-fill had the lowest bottom/top ratios, which were significantly different from those of the other materials. There was no significant difference between the different time intervals for bottom/top ratios within each material. Conclusion: Increased irradiation intervals positively affected the VHN of hybrid and dual-cure bulk-fill. BFRBCs showed clinically acceptable bottom/top hardness ratios.   How to cite this article: Aytaç Bal F, Ağaccıoğlu M, Demir O. A comparative study of the 5 mm-layer Vickers hardness model with bulk-fill resin-based composites. Int Dent Res 2021;11(2):172-9. https://doi.org/10.5577/intdentres.2021.vol11.no3.6   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    bulk-fill, dental composite, hardness, Vickers
    Fatma Aytaç Bal, Merve Ağaccıoğlu, Osman Demir
    31.12.2021
    172-179
    Abstract Views: 1537 Download: 667 DOI 10.5577/intdentres.2021.vol11.no3.6
  • The The effect of different solutions and thermocycling on the Vickers hardness of acrylic resin denture teeth

    Aim: The aim of this study was to evaluate the effect of artificial saliva, disinfectant solution, distilled water, and thermocycling on Vickers hardness of 4 commercial brands of acrylic resin denture teeth. Methodology: Four different brands of acrylic resin denture teeth (Major Dent, Acry Lux, Acry Rock, Imident Lux) were evaluated. 15 anterior and 15 posterior teeth of each group embedded in autopolymerized acrylic resin.  The occlusal surfaces of posterior teeth and the vestibule surfaces of anterior teeth were flattened by using silicon carbide paper. After polishing, microhardness measurements were repeated three times for each teeth. The teeth were submitted to different conditions: (1) storage in distilled water at 37±2°C for 7 days; (2) storage in artificial saliva at 37±2°C for 30 days and (3) storage in 1 % sodium hypochlorite. After, thermal cycling between 5 and 55 °C for 2500 cycles was made. The microhardness measurements were repeated. Data were analyzed with one-way analysis of variance (ANOVA) and Duncan test (p<0.05). Results: There were statistically significant differences between initial and final microhardness values of different brands of acrylic resin denture teeth. Anterior teeth showed lower microhardness values than posterior teeth. Conclusions: Storage in different solutions and thermal cycling significantly reduced the Vickers hardness of the acrylic resin denture teeth.   How to cite this article:  Özdemir H, Duymuş ZY. The effect of different solutions and thermocycling on the Vickers hardness of acrylic resin denture teeth. Int Dent Res 2018;8(3):117-22.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Solution, hardness, acrylic resin teeth, thermocycling
    Hatice Özdemir, Zeynep Yeşil Duymuş
    30.12.2018
    117-122
    Abstract Views: 2041 Download: 741 DOI 10.5577/intdentres.2018.vol8.no3.4
  • Investigation of microhardness, surface roughness, and color change of preheated composite resins

    Aim: Applying heat is a method currently used to enhance the depth of polymerization in composite resin. This study aimed to evaluate the effects of heat treatment on resin hardness, color change, and surface roughness. Methodology: In this study, 64 samples (8 mm 2 × 2 mm 2 ) were produced (3M Filtek Universal, G-aenial A’CHORD, Neo Spectra and Clearfil Majesty ES-2) using a Teflon mold (n = 8). Half of the samples were preheated to 50 o C, while the other half were polymerized at room temperature. Initial color measurements were performed using a spectrophotometer, the surface roughness was assessed with a profilometer, and the microhardness was determined using a Vickers microhardness device. Subsequently, all samples were immersed in a coffee solution at 37 o C. The color changes were documented by the seventh day. The changes in color, roughness, and hardness of the materials were examined by the thirtieth day. Results: The groups that received heat treatment exhibited higher hardness values. The unheated G-aenial A’CHORD composite resin demonstrated the most significant color change by the end of the thirtieth day, while heated and unheated Clearfil Majesty ES-2 composite samples exhibited the least color change. By the end of the thirtieth day, the surface roughness of all samples increased significantly from the baseline, with the 3M Filtek Universal samples, both heated and unheated, showing the highest surface roughness. Conclusion: According to the results of this study, heat treatment of composite resins before polymerization reduces discoloration and improves hardness. Therefore, it is recommended to heat composite resins before application.   How to cite this article: Çekmez MB, Karaoğlanoğlu S, Aybala Oktay E, Aydın N, Ersöz B. Investigation of microhardness, surface roughness, and color change of preheated composite resins. Int Dent Res 2024;14(1):42-49. https://doi.org/10.5577/intdentres.523    
    Composite resin, microhardness, surface roughness, color change, preheating, polymerization
    Malhun Begüm Çekmez, Serpil Karaoğlanoğlu, Elif Aybala Oktay, Numan Aydın, Bilge Ersöz
    30.04.2024
    42-49
    Abstract Views: 2062 Download: 598 DOI 10.5577/intdentres.523
  • Investigation of nanohardness values of dual-cure, bulk-fill composite resins at different time intervals

    Aim: The aim of this study was to evaluate the surface hardness of dual-cure, bulk-fill composite resins at different depths and time intervals using nanoindentation. Methodology: In the study, a comparison was conducted of the nanohardness values of Fill-Up, HyperFIL, and Cention N dual-cure, bulk-fill composite resins in the experimental group and Reveal HD, a light-cured, bulk-fill composite, in the control group. The dual-cure, bulk-fill composites used in the experimental group were divided into two subgroups. The first group was polymerized with an LED light source, and the second group was chemically polymerized in line with the manufacturer's instructions. The dual-cure composite resins were prepared in two different depths, 5 mm and 10 mm. In the control group, specimens with a depth of 5 mm were prepared, and their polymerization was provided by an LED light source. The nanohardness values of the lower and upper surfaces of the samples were measured using the Hysitron TI 950 Triboindenter 24 hrs and 7 days after polymerization. Results: Following statistical evaluations, no statistically significant difference was found between the nanohardness values measured 24 hrs and 7 days after light or chemical polymerization of the dual-cured, bulk-fill composite resins. It was observed that light polymerization of HyperFIL and Fill-Up dual-cure, bulk-fill composite resins had no effect on nanohardness values. When Cention N dual-cure, bulk-fill composite resin was polymerized with a light source, higher values of nanohardness were obtained. Conclusion: It was determined that the investigated dual-cure, bulk-fill composites reached their final hardness after 24 hrs. In all groups, it was observed that the highest nanohardness values belonged to Cention N for both polymerization methods.   How to cite this article: Bolgül B, Özdemir E. Investigation of nanohardness values of dual cure bulk-fill composite resins at different time intervals. Int Dent Res 2021;11(Suppl.1):19-25. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  
    dual-cure, bulk-fill, composite resin, nanohardness, pediatric dentistry
    Eda Özdemir, Behiye Bolgül
    30.09.2021
    19-25
    Abstract Views: 2925 Download: 669 DOI 10.5577/intdentres.2021.vol11.suppl1.4
  • Mechanical behavior of newly developed glass carbomer-based dental filling material

    Aim: This study measured the microhardness of a newly developed glass carbomer dental filling material within the first 24 hours after setting and compared it against that of two different glass ionomers, with and without heating during setting, and a resin-modified glass ionomer. Methodology: Six cavities were prepared on acrylic resin discs. PMMA blocks were randomly divided into six groups of six cylinders and each cavity was filled with one of the tested materials according to their group. The groups were: Group1, Fuji Triage™ with heat; Group 2, GCP Glass Fill™; Group 3, Equia™ with heat; Group 4, Riva LC™; Group 5, Fuji Triage™; and Group 6, Equia™. Microhardness was measured by the Vickers hardness scale using a microindentation hardness tester at 2, 4, 6, 12 and 24 hours after initial setting of the materials. Results: After 24 hours, the glass carbomer  (GCP Glass Fill™) was not the strongest of the tested materials. Fuji Triage™ with heat applied during setting (Group 1) proved to be the hardest material, while Riva LC™ (Group 4) and GCP Glass Fill™ (Group 2) were the softest.  Heating the Fuji Triage™ during the initial setting period significantly increased its physical strength after 24 hours.   How to cite this article:  Arslanoğlu Z, Kale E, Meşe A, Altan H. Evaluation of microhardness of newly developed glass carbomer-based dental filling material. Int Dent Res 2019;9(2):58-62.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Glass carbomer, heat application, mechanical behavior, glass ionomer, Equia
    Zeki Arslanoğlu, Ediz Kale, Ayse Meşe, Halenur Altan
    31.08.2019
    58-62
    Abstract Views: 1691 Download: 735 DOI 10.5577/intdentres.2019.vol9.no2.4
  • The effect of antioxidants against electromagnetic field on enamel microhardness in rats

    Aim: In current studies, it is reported that exposure to electromagnetic field (EMF) is related to numerous illnesses. Important parts of our bodies, oral and dental tissues can also be influenced by the EMF. In this study, it was aimed to determine possible negative impacts of EMFs on dental enamel hardness and to test the efficiency of the antioxidant agents against possible adverse effects. Methodology: In this study, 4-month-old 32 Winster strain Albino rats were used, each weighing 250-300 gr in average. In total, 40 teeth were used from these 32 rats. These teeth were classified into four groups. Group 1 was determined as the control group, and Group 2,3, and 4 were exposed to EMF measured as 2.48 μT magnetic field intensity and 80.3 V / m electric field intensity for 52 days. Ganodermalucidum (20 mg/kg/ day) was applied to the Group 3 together with the EMF. Melatonin (10 mg/kg/ day) was applied to the Group 4 together with the EMF. The teeth pulled out after the euthanasia were embedded into acrylic blocks and micro-hardness test was applied. The normality of the variables was analyzed through the Shapiro-Wilk test. After the homogeneity test, one-way analysis of variance (ANOVA) was used to compare surface micro-hardness (p<0.05). Results: As a result of the conducted statistical analyses, there was statistically no significant difference among the groups concerning micro-hardness (P>0.05). Conclusions: It was determined in our study that 52-day exposure to 2.48 μT EMF did not cause any micro-hardness change in the tooth enamels of the rats. It was also observed that the used antioxidant agents did not cause any significant difference.    How to cite this article: Aras A,  Doğan MS, Yavaş MC. The effect of antioxidants against electromagnetic field on enamel microhardness in rats. Int Dent Res 2019;9(3):133-7.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Antioxidants, magnetic field, enamel, microhardness, melatonin
    Ahmet Aras, Mehmet Sinan Doğan, Mehmet Cihan Yavaş
    31.12.2019
    133-137
    Abstract Views: 1580 Download: 665 DOI 10.5577/intdentres.2019.vol9.no3.7
1 - 7 of 7 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information