Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Evaluation of stress distribution in restorations of maxillary central incisor with post-traumatic enamel-dentin fracture using two different techniques: A micro-computed tomography study

    Aim: The aim of this study is to investigate the stress distribution created by two restorative techniques, adhesive reattachment of the fractured fragment and direct composite restoration, used in the treatment of a maxillary central incisor with enamel-dentin fracture. The analysis is conducted using the finite element stress analysis method on a three-dimensional (3D) model prepared based on micro-computed tomography data, following the application of different adhesive procedures on fractured teeth. Methodology: The avulsed left maxillary central incisor was scanned using a micro-computed tomography device. The obtained data was transferred to a computer and used for 3D modeling. In the models, a fracture line was created obliquely at a 45° angle, 3 mm away from the mesial surface towards the distoincisal corner of the tooth. Six restorations were planned on this model: three direct composite restorations and three adhesives, reattachments followed by composite application. The models for the adhesive reattachment method included: (1) internal dentin groove, (2) palatal composite laminate veneer, and (3) double palatal retentive groove. The models for the composite restoration technique included: (1) composite laminate veneer, (2) direct composite restoration following enamel beveling, and (3) composite application after double palatal groove preparation. Upon completion of the restorations, a 100-N force was applied from the palatal direction using the finite element stress analysis method. The results were analyzed to examine the amount and distribution of stress on the restorations and the tooth. Results: In all models, the highest stress values within tooth structures were observed in the enamel. The lowest stress value in the enamel layer was seen in model R-1, whereas the highest stress value was observed in model K-2. For direct composite restorations, the stresses on enamel, dentin, and restoration were relatively similar in each model, with no significant differences noted among these values. Among all applied composite restorations, the lowest stress value was observed in model R-3. When analyzing the stresses generated at the tooth-restoration and tooth-fractured fragment interface of the six models, the lowest stress in the enamel was observed in models R-1 and K-3, while the highest stress was seen in model R-3. Conclusion: According to the data obtained from the models, the shape of the restoration applied on the tooth, the technique used, and the location of the restoration affect the amount and distribution of stress accumulated in the tooth and restoration. However, the stress analysis results are not sufficient to evaluate the clinical success of restorations. There is a need for further studies utilizing different techniques to support the models used.   How to cite this article: Olgaç Akgönül Ş, Çelenk S, Adıgüzel Ö. Evaluation of stress distribution in restorations of maxillary central incisor with post-traumatic enamel-dentin fracture using two different techniques: A finite element analysis based on micro-computed tomography data. Int Dent Res 2024;14(2):76-83. https://doi.org/10.5577/intdentres.535
    Reattachment technique, stress distribution, finite element analysis, micro-computed tomography, direct composite restoration, enamel dentin fracture
    Seyma Olgaç Akgönül, Sema Çelenk, Özkan Adıgüzel
    31.08.2024
    76-83
    Abstract Views: 2809 Download: 523 DOI 10.5577/intdentres.535
  • An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study

    Aim: Metal-supported ceramics as crown material and glass fiber posts as dental post materials are in frequent current use. In recent years, it has been claimed that stress-based biomechanical problems in dentistry can be resolved with the benefit of the low elasticity modulus of polyetheretherketone (PEEK) material. The aim of this study was to use finite element analysis (FEA) to compare the stresses formed by forces applied after the use of PEEK material as dental post and crown material as an alternative to glass fiber posts and metal-supported ceramic crowns. Methodology: The stress analysis method used in this study was FEA. First, micro-computed tomography (micro-CT) images were obtained of a maxillary central incisor tooth and the data of the post materials scanned with a 3-dimensional (3D) laser scanner were uploaded to a computer program. 3D models were obtained with designs made in the computer program of all the materials. The modelling of a maxillary central tooth was completed using 2 different post materials (glass fiber and PEEK) and 2 different crown materials (metal ceramic and PEEK) and 4 groups were formed for analysis. By applying force of 100 N at 135 o from the absolute central point of the palatinal surface of the tooth, the stress values and distribution occurring in the 3D periodontal models were compared. Results: The use of PEEK post reduced the stresses occurring on the periodontal ligament (PDL) and the cortical bone, and caused no significant change in the stresses on the crown. The use of PEEK crown reduced the stresses occurring on the crown and increased the stresses occurring on the PDL and cortical bone. Conclusions: With further in vitro and clinical studies of PEEK material, it can be considered that within a short time PEEK post and PEEK crown could be in routine use in dentistry.   How to cite this article:  Tekin S, Adıgüzel Ö, Cangül S. An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study. Int Dent Res 2018;8(3):144-50.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Polyetheretherketone, PEEK post, glass fiber post, PEEK crown, finite element analysis, micro-CT
    Samet Tekin, Özkan Adıgüzel, Suzan Cangül
    30.12.2018
    144-150
    Abstract Views: 4697 Download: 1137 DOI 10.5577/intdentres.2018.vol8.no3.8
  • 3D micro-CT analysis of void formation of glass fiber posts bonded using different resin cements

    Aim: The aim of this in vitro study was to evaluate and compare the void volumes at the dentin–post interface when glass fiber posts were bonded using different resin cements, as assessed by 3D micro-computed tomography (µCT). Methodology: For this investigation, thirty extracted human maxillary central incisors with a single root were chosen. The specimens were divided into three groups at random (n = 10) and restored with glass fiber posts that were cemented using Variolink N, Panavia F 2.0, and RelyX Unicem resin cements, respectively. A resolution of 13.7 µm was used for high-resolution µCT scanning to obtain detailed images of the specimens. The Kruskal–Wallis test (post hoc: Mann–Whitney U with Bonferroni correction), the Friedman test, and the Spearman rank correlation test (α = 0.05) were used for statistical evaluation. Results: µCT analysis revealed that the mean total void volume at the dentin–post interface was 1.67 ± 0.69 mm³ for the Variolink N group, 2.59 ± 1.75 mm³ for the Panavia F 2.0 group, and 3.28 ± 2.13 mm³ for the RelyX Unicem group. The differences between the groups were statistically significant (p < 0.05), with the lowest void volume in the Variolink N group and the highest in the RelyX Unicem group. Within each group, void formation was distributed homogeneously across root levels (p > 0.05), whereas specimens cemented with RelyX Unicem showed significantly higher void formation in the apical third than the other two cements (p < 0.05). No correlation was found between empty canal volume or empty canal surface area and void volume (p = 0.34 and p = 0.19, respectively). Conclusion: Post-cementation analysis revealed significant differences in total void volume among the resin cements, whereas within-group regional comparisons did not yield statistically significant differences. Decementation of fiber posts is frequently associated with voids within the luting cement layer, so the choice of resin cement and its delivery technique remains clinically relevant.
    Fiber post, resin cement, micro-CT, void formation, luting agent
    Zuhal Görüş, Anastasiia Bilei, Hayriye Yasemin Yay Kuşçu, Nur Sena Alioğlu Koparal
    18.08.2026
    e260766
    Abstract Views: 707 Download: 197 DOI 10.5577/intdentres.766
1 - 3 of 3 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information