Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Does preheating affect the microleakage of bulk-fill composite restorations?

    Aim: Microleakage is one of the most important factors in restoration failure in today’s dentistry. The aim of this in vitro study is to evaluate the microleakage of preheated bulk-fill composites. Methodology: In the study, 160 slot cavities prepared in the mesial and distal of 80 molar teeth were used. In the gingival of the cavities, Estelite Bulk Fill Flow (Tokuyama, Tokyo, Japan) in the mesial and SDR ® Posterior Bulk Fill Flowable Base (Dentsply, DeTrey, Konstanz, Germany) in the distal were used, and the remaining occlusal parts were restored using Filtek TM One Bulk Fill Restorative (3M, St Paul, MN, US). Composites were applied at four different temperatures (4 o C, room temperature, 39 o C and 55 o C). After finishing and polishing, specimens were thermocycled and then placed in 0.5% methylene blue for 24 hours. Specimens were sectioned into two parts in a mesiodistal direction, and the microleakage levels were examined by a stereomicroscope (x40). Results: In the statistical evaluation of the microleakage levels of Filtek TM One Bulk Fill Restorative applied at four different temperatures on the occlusal surface with One-way ANOVA, it was observed that there was a significant difference between the groups ( p =0.02). In the comparison of the microleakage values of Estelite Bulk Fill Flow applied in the gingival region with the one-way ANOVA test at four different temperatures, there was no statistically significant difference between the groups ( p >0.05), while there was a significant difference between the groups using SDR ® Posterior Bulk Fill Flowable Base ( p =0.002). The highest microleakage values were observed at 4 o C in all groups. Conclusion: The results obtained in the study show that heating bulk fill composites before polymerization is effective in reducing microleakages, but longer in vivo studies are required.   How to cite this article: Aktuğ Karademir S, Akarsu S. Does preheating affect the microleakage of bulk fill composite restorations?. Int Dent Res 2024;14(2):84-92. https://doi.org/10.5577/intdentres.481
    Bulk-fill composite, preheating, microleakage, composite restorations
    Sultan Aktuğ Karademir, Serdar Akarsu
    31.08.2024
    84-92
    Abstract Views: 1284 Download: 596 DOI 10.5577/intdentres.481
  • Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays

    Aim: The aim of the study was to evaluate the fracture resistance and microleakage of different CAD-CAM inlay restorations. Methodology: Inlay restorations from nine restorative materials as monolithic zirconia (TZI), resin nano ceramic (LU), hybrid ceramic (VE), feldspathic ceramic (CB), zirconia reinforced lithium silicate (VS), lithium disilicate (e.max), leucite reinforced glass ceramic (Emp), resin ceramic (GCS), and conventional composite resin (CR) were used (n=10). For evaluating the fracture resistance, restorations were cemented to resin teeth and subjected to thermomechanical aging. The data of fracture resistance were analyzed using One-way Analysis of Variance (ANOVA) and Games-Howel tests (a=0.05). For evaluating the microleakage, restorations were cemented on human teeth and subjected to thermocycling. The teeth were vertically sectioned into two parts and microleakages were assessed as yes or no.  Results: The highest and lowest fracture resistance values were found in TZI and LU groups, respectively ( p >0.05). The most frequent microleakage was observed in TZI and CR groups, and the least microleakage was seen in the VE group. Microleakage was frequently found in cervical surfaces and followed by occlusal, axial, and pulpal surfaces. Conclusion: Hybrid ceramics showed similar fracture resistance with the monolithic zirconia; besides, the lowest microleakage was observed for these ceramics. Hybrid ceramics may be a good alternative for inlay restorations.   How to cite this article: Bankoğlu Güngör M, İnal CB, Hürbağ M, Toksoy B, Turhan Bal B, Karakoca Nemli S. Effect of aging on the fracture resistance and microleakage of CAD-CAM-produced ceramic inlays. Int Dent Res 2024;14(1):10-18. https://doi.org/10.5577/intdentres.324
    CAD-CAM, ceramic, inlays, aging, fracture resistance, microleakage
    Merve Bankoğlu Güngör, Ceyda Başak İnal, Meryem Hürbağ, Burcu Toksoy, Bilge Turhan Bal, Seçil Karakoca Nemli
    30.04.2024
    10-18
    Abstract Views: 1477 Download: 533 DOI 10.5577/intdentres.324
  • Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study

    Aim: Using AutoCAD, we examined the microleakage of permanent molars in Class I restorations using a conventional posterior composite resin, a bulk-fill composite resin, and a high-viscosity glass-ionomer cement (HVGIC). Methodology: In total, 33 extracted noncarious third molars were used. Class I cavities were prepared. The teeth were randomly divided into three groups of 11 teeth each, as follows: Group A (Filtek Z550), Group B (Filtek Bulk-Fill Posterior Restorative), and Group C (EQUIA Fil). All specimens were stored for 24 h at 37 °C in distilled water. The teeth were thermocycled 1,000 times between 5 ± 2°C and 55 ± 2°C prior to immersion in 0.5% basic fuchsin for 24 h. Two mesiodistal cuts of each tooth were photographed under a stereomicroscope equipped with a digital camera. The dye-infiltrated surface area was measured. Results: Statistical evaluations were performed by one-way analysis of variance [ANOVA]. One-way ANOVA showed no significant difference between the three groups in microleakage (P = 0.07). However, the lowest microleakage ratio was seen in Group C (EQUIA Fil).  Similar results were obtained with all tested materials, but the lowest microleakage rate was obtained with EQUIA Fil (Group C). Conclusion: In this study, the tested materials were not completely successful in eliminating microleakage, although the lowest microleakage rate was obtained with EQUIA Fil.   How to cite this article: Çelenk S, Ataş O, Ayna B, Günay A. Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study. Int Dent Res 2022;12(1):34-8. https://doi.org/10.5577/intdentres.2022.vol12.no1.6   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    composite resin, high-viscosity glass-ionomer cement, microleakage, AutoCAD
    Sema Çelenk, Osman Ataş, Buket Ayna, Ayşe Günay
    30.08.2022
    34-38
    Abstract Views: 1676 Download: 576 DOI 10.5577/intdentres.2022.vol12.no1.6
  • Investigation of microleakage of polymerized with LED and halogen light devices four different restorative materials

    Aim: This study aimed to evaluate the in vitro effects on microleakage of LED and halogen light devices used in the polymerization of monomer structure composite resins of different viscosities and inorganic filling particle size applied to standard class V cavities in primary teeth. Methodology: 80 non caries primary molar teeth with standard class v cavity on the buccal surfaces were used. The teeth were randomly divided into 4 main groups and restored with composite resins (Herculite® XRV, Ultra™, Filtek™ Silorane, Vertise™ Flow, Æliteflo™). Each group was divided into 2 sub-groups for polymerization with LED or halogen light devices. Following the thermal cycle and subsequent procedures, the dye penetration method was used to evaluate microleakage. The microleakage scores were evaluated using the Kruskal-Wallis and Mann-Whitney U-tests. Results: According to the results of the statistical analysis, in polymerization made with halogen and LED light devices at the occlusal edge, the microleakage scores from lowest to highest were as follows: Filtek™ Silorane < Herculite® XRV Ultra™ < Æliteflo™ < Vertise™ Flow. In polymerization made with halogen and LED light devices at the gingival edge, the microleakage scores from lowest to highest were as follows: Filtek™ Silorane < Herculite® XRV Ultr™ < Vertise™ Flow < Æliteflo™. Conclusion: In the polymerizations made by using LED and halogen light devices, Herculite® XRV Ultra™, was found to be successful as it showed similar values to Filtek™ Silorane, which gave the best results in terms of microleakage. Moreover, as we have reached similar findings in our thesis study in respect of microleakage, in cases indicating the use of flow composite resin materials such as Æliteflo™, Vertise™ Flow can be used as it has the advantage of ease application and thus provide an ideal alternative in pediatric dentistry.   How to cite this article: Günay A, Tümen EC. Investigation of microleakage of polymerized with LED and halogen light devices four different restorative materials. Int Dent Res 2020;10(3):73-9. https://doi.org/10.5577/intdentres.2020.vol10.no3.2   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Primary tooth, microleakage, class V cavity, light devices
    Ayşe Günay, Emin Caner Tümen
    31.12.2020
    73-79
    Abstract Views: 1669 Download: 598 DOI 10.5577/intdentres.2020.vol10.no3.2
  • The evaluation of effectiveness of adhesive systems on dental amalgam restorations

    Aim: The purpose of this study was to evaluate the effectiveness of different adhesive systems in amalgam restorations and their effects on microleakage. Methodology: In this study, 105 caries-free extracted human permanent molar teeth were used. Teeth were randomly assigned to five groups (n=21), and class I cavities were created on the surface of each tooth. The first was a control group to which no adhesive system was applied. Amalgam Liner (VOCO GmbH, Cuxhaven Germany) was applied to Group II, Clearfil SE-Bond (Kuraray Europe GmbH, Frankfurt Germany) was applied to Group III, Panavia F 2.0 (Kuraray Europe GmbH, Frankfurt Germany) was applied to Group IV, Amalgambond Plus (Parkell Inc.Edgewood, NY USA) was applied to Group V, and then amalgam (Tytin, Kerr, California USA) restorations were placed. After the polishing process, samples were subjected to thermocycling 1,000 times. Teeth were sectioned bucco-palatinally/lingually, and microleakage scores of the occlusal walls were evaluated under a stereomicroscope at 15X magnification by a standardized scale ranging from 0 to 4. One tooth was selected randomly from each group for SEM (Scanning Electron Microscope), and SEM LEO EVO 40 (LEO Ltd., Cambridge UK) photographs of amalgam-tooth hard tissue interfaces were also taken at different magnifications. The results of the microleakage tests were statistically analyzed by both the Kruskal-Wallis Test and the Mann Whitney U Test. Results: In terms of microleakage among groups, the differences that were determined were significant (p<0.05). Microleakage within the control group was determined to be the highest, and statistically important differences were observed between the other groups. Group V (Amalgambond Plus) was determined to have the lowest microleakage scores. Conclusion: In prepared class I cavities, amalgam adhesive systems are effective in preventing occlusal microleakage but do not completely blocked it.   How to cite this article: Ünal M, Atakul F. The evaluation of effectiveness of adhesive systems on dental amalgam restorations. Int Dent Res 2021;11(2):83-92. https://doi.org/10.5577/intdentres.2021.vol11.no2.5   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    dental amalgam, adhesive, scanning electron microscope
    Mehmet Ünal, Fatma Atakul
    31.08.2021
    83-92
    Abstract Views: 1728 Download: 798 DOI 10.5577/intdentres.2021.vol11.no2.5
  • Evaluation of marginal microleakage in composite restorations with different placement techniques

    Aim: The purpose of this in vitro study was to evaluate the effect of different layering techniques (bulk, oblique, centripetal, split horizontal) on the marginal microleakage of Class II adhesive restorations. Methodology: Forty-eight standardized Class II cavities were prepared on both mesial and distal sides of extracted non-carious human molar teeth. Following preparation, all specimens were randomly divided into four groups (n=12). Group 1: bulk technique; Group 2: oblique incremental technique; Group 3: centripetal incremental technique; Group 4: split horizontal incremental technique. The teeth were restored with a total-etch adhesive system and a microhybrid composite resin. After thermocycling and immersion in a 0.2% methylene blue solution for 24 hours, the restorations were sectioned, and dye penetration was evaluated under a stereomicroscope. The microleakage scores (0 to 4) obtained from the occlusal and gingival margins were analyzed with Kruskal-Wallis and Mann-Whitney U tests (p<0,05).   Results: Incremental placement techniques showed lower microleakage compared with bulk and lower microleakage was seen at occlusal margin compared with gingival margin. However, there were no statistically significant differences among four placement techniques and the margins (p>0,05). Conclusions: Based on the results of the present study, none of the four placement techniques were found to be effective in eliminating marginal microleakage entirely in Class II restorations. All of the placement techniques showed similar results when the cavity margins were located on the enamel.   How to cite this article:  Misilli U, Yılmaz F. Evaluation of marginal microleakage in composite restorations with different placement techniques. Int Dent Res 2018;8(2):70-7.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Composite resin, incremental technique, microleakage, polymerisation shrinkage
    Umut Misilli, Fikret Yılmaz
    27.08.2018
    70-77
    Abstract Views: 2259 Download: 1193 DOI 10.5577/intdentres.2018.vol8.no2.4
  • Comparative evaluation of the dimensional compatibility of ISO #30/.06 gutta-percha cones from four different manufacturers using an endodontic gauge

    Aim: Gutta-percha is the most commonly used biocompatible obturation material in endodontics for the three-dimensional and hermetic sealing of the root canal system. However, despite the dimensions defined in the ISO 6877 standard, dimensional discrepancies between gutta-percha cones and endodontic files have been reported. The aim of this study was to comparatively evaluate the dimensional variability of ISO #30/.06 gutta-percha cones from four different manufacturers using an endodontic gauge. Methodology: A total of 240 ISO #30/.06 gutta-percha cones (n = 60 per brand) from four manufacturers (ProTaper Ultimate, MetaBiomed, Diadent, and EndoArt) were evaluated. Cone diameters were measured at the D0, D5, D10, and D15 levels using a Woodpecker R1 Plus endodontic gauge. Based on the ISO 6877 nominal dimensions, measurements were categorized as undersized, within the nominal range, or oversized. Statistical analysis was performed using Pearson's chi-square and Fisher's exact tests with Bonferroni correction (p < 0.05). Results: Dimensional discrepancies from the nominal ISO values were observed across all measurement levels, with statistically significant differences among the brands (p < 0.05). ProTaper Ultimate and MetaBiomed showed the highest compatibility with nominal dimensions, whereas EndoArt exhibited a consistently high proportion of undersized cones (57.1–67.2%) across all regions. Diadent showed a notably high proportion of oversized cones at the D15 level (66.7%). Effect sizes for between-brand comparisons were large at every level (Cramer's V = 0.386–0.503). Conclusion: ISO #30/.06 gutta-percha cones from different manufacturers did not show complete dimensional compatibility. These discrepancies may adversely affect apical adaptation, particularly in single-cone obturation techniques, potentially reducing clinical success. The use of an endodontic gauge provides a practical means of objectively verifying cone–canal adaptation in clinical practice, helping to prevent microleakage and obturation errors.
    Gutta-percha, endodontic gauge, dimensional compatibility, root canal treatment, dimensional accuracy, ISO 6877, root canal obturation
    Kumru Şaz, Hülya Nur Nalbant, Celalettin Topbaş
    11.07.2026
    e260664
    Abstract Views: 505 Download: 157 DOI 10.5577/intdentres.664
  • The Latest Developments Related to Composite Resins

    In the field of restorative dentistry, the use of composites has become widespread with increasing aesthetic demand. Nowadays the composites are divided into various classes depending on the type and size of the filler particles. Apart from this, many new composites have been produced in order to protect the healthy tooth structure, to reduce microleakage and secondary caries formation, to reduce marginal pigmentation and postoperative sensitivity together with developments in technology. The aim of this review is to improve the clinical performance and to evaluate new composite resins that will provide more selection criteria for dentists. How to cite this article: Cangul S, Adiguzel O. The latest developments related to composite resins. Int Dent Res 2017;7:32-41.
    Composite resin, particle size, microleakage, marginal coloration
    Suzan Cangul, Ozkan Adiguzel
    31.08.2017
    32-41
    Abstract Views: 6840 Download: 3001 DOI 10.5577/intdentres.2017.vol7.no2.3
  • Comparing MTA and Ketac Molar Easymix for Furcation Perforation Repair using a Volumetric Method

    Aim: We compared the ability of mineral trioxide aggregate (MTA) and Ketac Molar Easymix (KM) to repair furcal perforations in extracted human molars, based on the volume of methylene blue dye penetration. Methodology: In total, 44 human mandibular molars were divided randomly into two (n = 20 each) experimental groups, with two teeth used as positive controls and two teeth without perforations used as negative controls. Group 1 was repaired with MTA and group 2 with Ketac Molar Easymix. The volumetric determination of dye penetration was based on the molecular characteristics of methylene blue. The standard area of a methylene blue particle is known and the surface area can be calculated. We converted the dye penetration area into a volume and performed quantitative analyses. Results: Volume measurement using the dye penetration method showed that KM resulted in more microleakage than MTA (p < 0.05). Conclusions: Mineral trioxide aggregate resulted in significantly less dye leakage than Ketac Molar Easymix using a volumetric measurement method.   How to cite this article:  Kaya S,  Ganidağlı Ayaz S, Doğan MS,  Aydın H.  Comparing MTA and Ketac Molar Easymix for furcation perforation repair using a volumetric method. Int Dent Res 2011;1:13-17.  
    MTA, Ketac Molar Easymix, volume measurement method, methylene blue
    Sadullah KAYA, Selengül GANİDAĞLI AYAZ, Mehmet Sinan DOĞAN, Haluk AYDIN
    15.04.2011
    Abstract Views: 2420 Download: 677 DOI 10.5577/intdentres.2011.vol1.no1.3
1 - 9 of 9 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information