Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • Examination of the Effect of Preheating Process on Microtensile Bond Strength in the Cementation of Indirect Restorations The Effect of Preheating Process on Microtensile Bond Strength

    Aim: The aim of this study was to investigate the effect of preheating of inlay and onlay restorations prepared from composite materials and using a CAD/CAM device on microtensile bond strength in different structures. Methodology: In this study, 90 impacted human third molar teeth unaffected by the mouth environment were used. These teeth were divided into 3 groups. MOD inlay cavity preparation was performed on all samples according to the parameters specified. For the first group, restorations were prepared using a CAD/CAM device. For the second group, a fiber-reinforced composite (EverX Posterior, GC, Tokyo, Japan) was used on the bottom of the cavity to simulate dentin structure. Restoration was then completed using the laboratory composite system (Gradia, GC, Tokyo, Japan). For the third group, restorations were completed using the laboratory composite system (Gradia, GC, Tokyo, Japan) alone. Er,Cr:YSGG laser (Fotona Laser AT Fidelis Plus III, Slovenia) was administered on all prepared restorations for surface roughening. In the cementation of the restorations, resin cement was administered with and without preheating. The prepared samples were placed in a microtensile tester, and the sticks were broken off by setting the loading speed at 1 mm/min. The prepared samples were tested for microtensile bond strength (Microtensile Tester, Bisco, Schaumburg, IL, USA). The results obtained in Newtons were divided into the surface area and converted to MPa. The results were recorded as microtensile bond strength values. Results: There was no statistically significant difference between the groups in terms of the statistical evaluation of the microtensile bond strengths of the samples in which the adhesive cement was pre-heated (P) and not pre-heated (N) during the cementations (p>0.05). There was a statistically significant difference (p<0.05) in terms of the microtensile bond strength values between the groups in which the adhesive cement was pre-heated during the cementation of restorations. Conclusion: It was observed that exposure of the adhesive cement to preheating in the cementation of the EverX Posterior-based inlays adversely affects the bond strength. It was observed that the preheating process statistically significantly increased the bond strength in the inlays made using the Gradia composite. Preheating of the cement in the cementation of Cerasmart composite inlays produced using the CAD/CAM system did not affect the microtensile bond strength.       
    Preheating, CAD/CAM, microtensile, fiber-reinforced composite
    Zuhal Görüş
    30.04.2018
    15-21
    Abstract Views: 1729 Download: 990 DOI 10.5577/intdentres.2018.vol8.no1.3
  • Evaluation of the effect of shelf life of different universal bond systems on dentin bonding

    Aim: The aim of this study was to investigate changes in dentin bonding caused by the expiry of shelf life of five universal bond systems. Methodology: According to the manufacturer’s instructions, both expired and non-expired samples of five universal bond agents [Prime&Bond (Dentsply), Solare Bond (GC), OptiBond (Kerr), Clearfil S Bond (Kuraray), and G-Premio Bond (GC)] were applied to 10 human teeth. Composite blocks measuring 4–5 mm in thickness were then created on the teeth following the application of the bond. The teeth were cut to obtain samples in the form of square sectioned rods approximately 1.0 × 1.0 mm in width and 8–9 mm in length. These samples were then subjected to microtensile bond strength testing, and the results were statistically analyzed ( p <0.05). Results: When evaluating the difference in microtensile bond strength between expired and non-expired adhesive agent groups of the same brand at different shelf life stages, there was a significant decrease between the Kerr, Clearfil, and G-Premio groups ( p <0.05), while no significant difference was found in the Prime&Bond and Solare groups ( p >0.05). When microtensile bond strength values were assessed among different groups based on shelf life, no significant difference was observed ( p >0.05). Among expired adhesive agents, Solare exhibited the highest microtensile bond strength, while among non-expired adhesive agents, G-Premio showed the highest microtensile bond strength. Conclusion: Universal bond systems should be used in accordance with the manufacturer’s instructions under appropriate storage conditions and considering the shelf life. However, it has been shown that there is no difference in bond strength of universal bond systems within the first six months following the expiration date indicated; they can be used during this period if stored under appropriate conditions.   How to cite this article: Bas A, Çelikel P. Evaluation of the effect of shelf life of different universal bond systems on dentin bonding. Int Dent Res. 2024;14(3):129-134. https://doi.org/10.5577/intdentres.579
    Bonding agents, shelf life, universal bond system, microtensile bond strength
    Aybike Bas, Periş Çelikel
    31.12.2024
    129-134
    Abstract Views: 1704 Download: 584 DOI 10.5577/intdentres.579
  • Comparative evaluation of the effects of sodium ascorbate, alcohol, and calcium hydroxide on the bond strength of composite resin to dentin in non-vital teeth bleaching

    Aim: The aim of this in vitro study was to investigate the effects of sodium ascorbate, alcohol, and calcium hydroxide as a buffering agent on composite resin-dentin bond strength of non-vital teeth bleaching. Methodology: For our study, we used 80 human upper central teeth. An endodontic access cavity was opened on the palatal surface of the teeth. The root portion of the teeth was removed 2-3 mm below the enamel-cementum junction. Sodium perborate was used for the nonvital bleaching of all teeth. Following bleaching, four experimental groups were created: sodium ascorbate, alcohol, calcium hydroxide, and a control group. 1x1 mm specimens were obtained using a precision cutting device in all four experimental groups restored with bond and composite resin. The specimens were then subjected to tension tests in a microtensile device, and the resulting data were compared in terms of composite resin-dentin bond strength. Results: The study data were analyzed using the Kruskal-Wallis H test due to non-normal distributions of variables to compare groups. If the Kruskal-Wallis test indicated significant differences, a post-hoc multiple-comparison test was used to identify which groups differed. The Shapiro-Wilk test was used to determine whether the variables followed a normal distribution, based on the number of units. A statistically significant difference in binding strength was found between the study groups ( p <0.05). Specifically, the binding strength value of the sodium ascorbate group was significantly higher than that of the calcium hydroxide and control groups ( p <0.05). However, no statistically significant difference was observed between the other groups. Conclusion: After non-vital bleaching, sodium ascorbate can be used to improve the bond strength between composite resin and dentin. Further studies are needed to support the effect of alcohol and calcium hydroxide applications on bond strength.
    non-vital bleaching, bond strength, sodium perborate, sodium ascorbate, alcohol, calcium hydroxide
    Beyhan Başkan, Özkan Adıgüzel
    30.04.2025
    38-44
    Abstract Views: 1534 Download: 429 DOI 10.5577/intdentres.536
1 - 3 of 3 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information