Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2146-1767
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing Service
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics & Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Research Ethics Policy
    • Publication Ethics Policy
  • Journal Info
    • About
    • Abstracting & Indexing
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Useful Links
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • The comparison of cyclic fatigue resistance of two different reciprocal files according to different access angles into the root canal

    Aim: Root canal preparation is one of the most important steps of root canal treatment. Preparation procedure includes disinfection and shaping protocols. Ni-Ti rotary file systems are usually used for shaping. The biggest disadvantage of the usage of Ni-Ti rotary file systems is that the file gets broken during the treatment. There are many reasons for the breakage of files. One of the reasons may be the increase in the access angle. The purpose of this study is to compare the cyclic fatigue of reciprocating Reciproc and WaveOne Gold rotary systems according to different angles of accessing the root canal of Ni-Ti files. Methodology: In our study, 90 root canal files were used, 45 of which is Reciproc R25 (VDW GmbH, Munich, Germany) and the other 45 of which is WaveOne Gold Primary 25/07 (Dentsply, Maillefer, Ballaigues, Switzerland). Specially designed and manufactured stainless steel artificial roots whose curvature angle is 60° and curvature radius is 5 mm, which replicates the clinical conditions, were arranged. By enabling the files access the roots at 0°- 15°- 30° degrees, the lap numbers that they do till they break due to cyclic fatigue were examined. Results: When looking at the lap numbers that the Reciproc and WaveOne Gold root canal files do till they break, at accessing the roots at the same angles WaveOne Gold root canal file makes more lap numbers at all angles when compared with the Reciproc root canal file. Significant results were found when the groups were compared within one another and between groups and among all numeric data in the statistical analysis performed. It was also found that WaveOne Gold root canal file had more cyclic fatigue resistance. When the groups were compared within one another, it was found that the increase in the root access angle decreases the cyclic fatigue resistance of the files (p<0.05). No significant difference was found in the statistical analysis for comparison of the length of the broken file pieces (p=0.01). It was analyzed that when the broken files were examined via scanning electron microscope, file breakages occurred due to cyclic fatigue. Conclusion: Not only do the design features and production technology affect the breakage resistance due to cyclic fatigue of the root canal, the access angle to the roots affects the cyclic fatigue of the root canal files, as well.   How to cite this article: Adıgüzel Ö, Dundar M, Kaya S. The comparison of cyclic fatigue resistance of two different reciprocal files according to different entry angles into the root canal. Int Dent Res 2021;11(Suppl.1):114-21. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.18   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    cyclic fatigue, Reciproc, WaveOne Gold, reciprocating motion, access angle, static test model
    Mehmet Dundar, Özkan Adıgüzel, Sadullah Kaya
    30.09.2021
    114-121
    Abstract Views: 2598 Download: 677 DOI 10.5577/intdentres.2021.vol11.suppl1.18
  • Evaluation of dentinal micro-cracks caused by the ProTaper Universal, ProTaper Next and Reciproc rotary file systems used in root canal preparation

    Objective: In this study, we compared the occurrence of dentinal micro-cracks after use of the ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), and Reciproc (VDW, Munich, Germany) nickel–titanium rotary file systems in root canal preparation. Method: One hundred mandibular anterior teeth were divided into five groups of 20 specimens each. Group 1 served as a control, with no intervention. In group 2, preparation was performed using the step-back technique and K files. In groups 3–5, root canal preparation was performed using the ProTaper Universal, ProTaper Next, and Reciproc file systems, respectively. Following preparation, specimens were sectioned at 3, 6, and 9 mm using a Minitom precision cut-off machine. The sections were evaluated under a stereomicroscope. The following scoring system was used to rate specimens: 1, no micro-crack; 2, incomplete micro-crack; and 3, vertical root fracture. The results were statistically assessed ( p ≤ 0.05). Results: No micro-crack formation was observed in groups 1 and 2. The highest rate of micro-crack formation was observed in specimens prepared with the ProTaper Universal file system (20%), followed by those prepared with the Reciproc (11.7%) and ProTaper Next (6.7%) file systems. However, no significant difference was detected among groups ( p > 0.05). In the groups ProTaper Universal and Reciproc files were used, 1 vertical root fracture was found in 9 mm sections for each. Conclusion: Considering the limitations of in vitro studies, we can conclude that all rotary file systems used in this study led to dentinal micro-crack formation in roots. The ProTaper Universal file system caused more dentinal micro-cracking than did the ProTaper Next and Reciproc file systems.   How to cite this article:  Deveci Taç M, Kaya S, Falakaloğlu S. Evaluation of dentinal micro-cracks caused by the ProTaper Universal, ProTaper Next and Reciproc rotary file systems used in root canal preparation. Int Dent Res 2018;8(3):111-16.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Micro-crack, ProTaper Universal, Reciproc, ProTaper Next
    Meltem Deveci Taç, Sadullah Kaya, Seda Falakaloğlu
    30.12.2018
    111-116
    Abstract Views: 2197 Download: 1200 DOI 10.5577/intdentres.2018.vol8.no3.3
  • Comparison of the incidence of post-operative pain after low-level laser therapy between single- and multi-visit root canal treatments for chronic apical periodontitis: A prospective randomized clinical trial

    Aim: The aim of this clinical study was to evaluate the effect of low-level laser therapy, used in conjunction with conventional canal disinfection techniques, on post-operative pain after single- and multi-visit root canal treatments for chronic apical periodontitis. Methodology: 100 volunteers were randomly divided into 4 groups. The main inclusion criteria were radiographic evidence of apical periodontitis (minimum size of 2.0 × 2.0 mm) and a diagnosis of pulpal necrosis confirmed by a negative response to vitality tests. All the root canals were prepared using a standard shaping technique and irrigation procedure. In Groups I and III, the root canals were obturated during the first visit following chemo-mechanical preparation. In Groups II and IV, the root canals were medicated with calcium hydroxide and obturated during a second visit, 1 week later. In Groups III and IV, after the chemo-mechanical preparation, the root canals were additionally irradiated by an 810-nm diode laser at 1.5 W output for 20 seconds. A modified visual analogue scale was used to measure pain at 4, 8, 12, 24, and 48 hours and 7 days after the treatment. Results: There was no statistically significant difference between the groups in terms of post-operative pain at any time during the observation period (p > .05). Post-operative pain occurred only at 8 and 12 hours and at 1, 2, and 3 days in all groups. There was no correlation between the results regarding age, gender, periapical index scores, or tooth type. Conclusion: The use of low-level laser therapy had no significant effect on the incidence of post-operative pain, and single-visit root canal treatment may be a strong alternative to multi-visit treatment. How to cite this article:  Özkan Özcan H, Haznedaroğlu F, Gökyay S. Comparison of the incidence of post-operative pain after low-level laser therapy between single- and multi-visit root canal treatments for chronic apical periodontitis: A prospective randomized clinical trial. Int Dent Res 2021;11(1):30-7.  https://doi.org/10.5577/intdentres.2021.vol11.no1.6   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Post-operative pain, apical periodontitis, lasers, endodontics
    Helin Özkan Özcan, Faruk Haznedaroğlu, Selçuk Gökyay
    30.04.2021
    30-37
    Abstract Views: 2094 Download: 770 DOI 10.5577/intdentres.2021.vol11.no1.6
  • Root canal cleaning with different reciprocating and rotary instrumentation systems

    Aim: The purpose of the present study was to compare the cleaning effectiveness of two reciprocating single-file systems with ProTaper Next and ProTaper Universal rotary instruments during the preparation of single-rooted extracted teeth. Methodology: Sixty freshly extracted single-rooted human teeth were randomly divided into 4 groups (n=15). In group 1, root canals were prepared with ProTaper Universal, in group 2, they were prepared with ProTaper Next, in group 3, they were prepared with WaveOne and in group 4, root canals prepared with Reciproc systems. Canals were prepared to the following apical sizes: ProTaper Universal F3, ProTaper Next X3, WaveOne Primary and Reciproc 25. The irrigant in all groups was 2ml 2.5% sodium hypochlorite (NaOCl) solution, the final irrigation after preparation all groups was 2ml NaOCl, 2ml EDTA and 2ml saline solution. The roots were split longitudinally into halves and the canals examined using a scanning electron microscope. The presence of a debris and smear layer was recorded at the coronal, middle and the apical thirds of root canals using a five-step scoring scale. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: All groups showed more efficient smear layer and debris removal coronally than in the middle and apical regions, whereas the mean total debris score and the mean smear layer score in all groups were less in the WaveOne and the Reciproc groups. Conclusions: Under the conditions of this study, for root canal cleanliness Reciproc and WaveOne may be preferred rather than ProTaperUniversal and ProTaperNext.   How to cite this article: İnce Yusufoğlu S, Arı Aydınbelge H. Root canal cleaning with different reciprocating and rotary instrumentation systems. Int Dent Res 2019;9(1):1-8.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Debris, ProTaper Next, Reciproc, WaveOne, SEM
    Selen İnce Yusufoğlu, Hale Arı Aydınbelge
    30.04.2019
    1-8
    Abstract Views: 1621 Download: 1211 DOI 10.5577/intdentres.2019.vol9.no1.1
  • The effect of different final irrigation solutions on apical impermeability

    Aim: This study aimed to compare ethylenediaminetetraacetic acid (EDTA), phytic acid, and citric acid as chelation agents in final irrigation procedures on teeth with apical impermeability. Methodology: We used 66 mandibular premolar teeth with a single root and single canal extracted for periodontal or orthodontic reasons. All teeth crowns were removed to achieve a 14-mm root length. Mechanical preparation of the root canal was completed with a Reciproc R25 (VDW, Munich, Germany) file system. Teeth were randomly separated into three groups: Group 1: 5 ml 17% EDTA, Group 2: 5 ml 1% phytic acid, and Group 3: 5 ml 20% citric acid. We used 6 ml 5.25% sodium hypochlorite (NaOCl) in the mechanical preparation of all groups. Three teeth were selected for both the positive and negative control groups. All teeth in the experimental groups were filled by the lateral condensation method using AH Plus canal sealer and gutta-percha. For hardening of the canal sealer, samples were kept at 37 oC and at 100% humidity in a drying oven for 7 days. Later, following removal from the drying oven, two layers of nail polish were used to cover all but the apical 2 mm of each tooth. The teeth were then kept in 2% methylene blue solution at 37 oC for 7 days. The root was divided by cutting in the buccolingual direction and gutta-percha was removed. The dye leakage was measured linearly in millimeters (mm) under a stereomicroscope. Results: As a result of the apical leakage assessment, the lowest apical leakage is observed in the phytic acid group. There was a statistically significant difference between the phytic acid group and citric acid group. There was no statistically significant difference between other groups. Conclusion: While phytic acid showed similar results with EDTA on apical impermeability, it was more effective than citric acid.   How to cite this article: Akın Tartuk G, Kaya S, Adıgüzel Ö. The effect of different final irrigation solutions on apical impermeability. Int Dent Res 2021;11(Suppl.1):201-5. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.28   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    microleakage, EDTA, phytic acid, dye penetration test
    Gizem Akın Tartuk, Sadullah Kaya, Özkan Adıgüzel
    30.09.2021
    201-205
    Abstract Views: 2576 Download: 837 DOI 10.5577/intdentres.2021.vol11.suppl1.28
  • Evaluation of the effectiveness of reciprocal and conventional shaping systems and EDDY and CanalBrush activation systems in calcium hydroxide removal

    Aim: To compare the effectiveness of two preparation systems and two irrigation techniques in calcium hydroxide removal from straight root canals. Methodology: Forty-four mandibular premolar teeth were included in this study. The teeth were filled with a calcium hydroxide-based paste and randomly divided into two different preparation groups (Reciproc 50 (R50; VDW, Munich, Germany and ProTaper Universal F5 (PTU; Dentsply Maillefer, Ballaigues, Switzerland). Subsequently, the groups were divided into two subgroups and irrigated using EDDY (VDW, Munich, Germany) and CanalBrush (CB; Roeko, Langenau, Germany) irrigation activation systems. The percentage of calcium hydroxide removed from the canal walls was analyzed using a dental operating microscope (DOM) at 25× magnification. An independent samples t -test, a Mann–Whitney U, Wilcoxon’s tests were used for statistical analysis. Results: There was no significant difference in calcium hydroxide removal throughout the root canal using the R50 and PTU F5 preparation systems ( P = 0.847). Both activation systems significantly increased the amount of calcium hydroxide removed from the root canal. Conclusions: EDDY and CB significantly improved calcium hydroxide removal. There was no significant difference between the R50 and PTU F5 systems in calcium hydroxide removal. How to cite this article:  Keskin NB, İnce Yusufoğlu S. Evaluation of the effectiveness of reciprocal and conventional shaping systems and EDDY and CanalBrush activation systems in calcium hydroxide removal. Int Dent Res 2021;11(1):16-22.  https://doi.org/10.5577/intdentres.2021.vol11.no1.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Calcium hydroxide, CanalBrush, EDDY, Reciproc, root canal dressing
    Neslihan Büşra Keskin, Selen İnce Yusufoğlu
    30.04.2021
    16-22
    Abstract Views: 1748 Download: 635 DOI 10.5577/intdentres.2021.vol11.no1.4
  • The effects of different irrigation agents on root canal dentine micro-hardness and surface roughness

    Aim: Successful endodontic treatments rely on sufficient mechanical preparation and irrigation of the root canal followed by an adequate three-dimensional filling. This study investigated the changes in root dentine micro-hardness and surface roughness upon treatment with different irrigating agents. Methodology: A total of 60 human maxillary incisors and canine teeth were used in this study. The crowns of all teeth were decoronated and roots were divided longitudinally. The samples were separated into three groups prior to irrigation. A 5% NaOCl irrigation agent was applied to the first group, a QMix agent was used for the second group, and a 2% CHX agent was used for the third group. All irrigations were performed for 15 minutes. Following irrigation, microstructural and surface-roughness measurements were taken again from all samples. Results: Micro-hardness was not significantly different between QMix or 5% NaOCl (p>0.05). A significant difference was observed between the QMix- and 2% CHX-treated groups, and between the 5% NaOCl- and QMix-treated groups (p<0.05). A significant difference in surface roughness was observed between the QMix and 2% CHX, and between the 5% NaOCl and QMix (p<0.05). No difference in surface roughness was observed between 5% NaOCl or 2% CHX. The 5% NaOCl and QMix agents reduced the dentine micro-hardness equal to or more than that of the 2% CHX agent. The QMix agent also increased the dentine surface roughness significantly more than the other agents. The 5% NaOCl and 2% CHX agents increased surface roughness equally. Conclusions: It was seen that all of the irrigation agents used in our study affected dentin microhardness and surface roughness at different rates.   How to cite this article: Öztekin F, Adıgüzel Ö. The effects of different irrigation agents on root canal dentine micro-hardness and surface roughness. Int Dent Res 2019;9(1):16-21.   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Micro-hardness, surface roughness, QMix, NaOCl, CHX
    Faruk Öztekin, Özkan Adıgüzel
    30.04.2019
    16-21
    Abstract Views: 2918 Download: 1322 DOI 10.5577/intdentres.2019.vol9.no1.3
  • Effects of sonic irrigation activation on postoperative pain following root canal treatment of teeth with apical periodontitis

    Aim: To evaluate postoperative pain of teeth with apical periodontitis after sonic irrigation activation. Methodology: One hundred five asymptomatic patients with periapical lesions were included in this study. After chemomechanical canal preparation using rotary instruments and NaOCl, the teeth were randomly assigned to three groups (n=35 per group): control (conventional needle irrigation-CNI), manual dynamic irrigation activation (MDI), and sonic irrigation activation (SI). In each group, final irrigation was performed using 3 ml of 2.5% NaOCl and 2 ml of 17% EDTA solution, and the relevant activation method. Patients recorded their pain intensity at 24 h, 48 h, and 7 days after treatment on a modified visual analogue scale (VAS), as well as their analgesic consumption. Demographic data and pain levels were compared across groups using Fisher’s Exact and one-way ANOVA tests, with differences of p < 0.05 considered statistically significant. Results: There was a significant increase in pain levels at 24 and 48 hours postoperatively, and no difference was found between the groups (p = 0.1464 and p = 0.0655, respectively). At day 7 postoperatively, pain intensity and incidence were significantly lower in the SI group compared to the CNI and MDI groups (p = 0.0435). However, the frequency of analgesic intake did not differ significantly between the groups (p = 0.863). Furthermore, none of the methods resulted in any adverse effects. Conclusion: The conventional needle irrigation and manual dynamic activation used in this study were associated with a similar intensity of postoperative pain in asymptomatic patients receiving primary root canal treatment. However, on the seventh day, sonically activated irrigation resulted in lower postoperative pain.
    Apical periodontitis, irrigation, sonic activation, manual dynamic activation, postoperative pain, visual analog scale
    Şeyda Erşahan, Yelda Erdem Hepşenoğlu, Celalettin Topbaş
    31.12.2025
    175-182
    Abstract Views: 770 Download: 392 DOI 10.5577/intdentres.597
  • Prevalence of radix entomolaris and radix paramolaris in mandibular first and second molars in a Turkish population

    Aim: This retrospective study determined the prevalence and distribution of extra roots (radix entomolaris [RE] and radix paramolaris [RP]) in mandibular first and second molars in a southeastern Anatolian Turkish population using cone-beam computed tomography (CBCT). Methodology: A total of 2010 mandibular first and second molars from the archived CBCT images of 662 patients (325 males, 337 females) were evaluated for the associations of RE and RP with sex, side, molar type, and unilateral/bilateral presence. Fisher's exact test was used for categorical comparisons and McNemar's exact test for the paired right-left comparison at patient level; prevalences are reported with Wilson score 95% confidence intervals, and the 24 pairwise post-hoc comparisons were corrected for multiplicity by the Holm procedure. Results: An extra root was detected in 3.7% of the examined teeth (75/2010, 95% CI 3.0-4.7%) and 9.5% of the patients (63/662, 95% CI 7.5-12.0%). Prevalence did not differ significantly by sex (8.9% [29/325] in males versus 10.1% [34/337] in females, p = 0.61), side (McNemar exact p = 0.16), or unilateral/bilateral presence (p = 1.00). Although the overall per-tooth prevalence was similar in first and second molars (3.9% versus 3.6%, p = 0.73), the distribution of root type among the 75 affected teeth differed significantly (Fisher exact p = 0.002). RP was the most frequent type in both first (1.95%, 19/974) and second (3.09%, 32/1036) molars but exceeded RE significantly only in the second molars (RE 4/1036, p < 0.001; first molars RE 14/974, p = 0.49). Among the affected teeth, RP was relatively more common in the second molars (Holm-adjusted p = 0.025), whereas the excess of RE in the first molars did not survive correction for multiple testing (Holm-adjusted p = 0.26). Conclusion: The presence of extra roots in mandibular molars within the Turkish population is a key variation for access cavity preparation in endodontics. The different distributions of these roots between the first and second molars emphasize the need for a thorough pre-treatment radiographic assessment.
    Cone-beam computed tomography, root canal anatomy, prevalence, tooth abnormalities, radix entomolaris, radix paramolaris
    Ayşenur Çam, Merve Defişet, Merve Yeniçeri Özata, Özkan Adıgüzel
    07.08.2026
    e260663
    Abstract Views: 597 Download: 200 DOI 10.5577/intdentres.663
  • Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion

    Aim: The aim of this study is to evaluate the amount of debris extruded apically by the primary shaping files of three rotary file systems manufactured with different alloy technologies [TruNatomy (TRN), ProTaper Ultimate (PTUltimate), and VDW.Rotate (VDW.R) files]. Methodology: Thirty lower premolar teeth with moderate curvature (10-20°) were randomly divided into three equal groups (n=10) according to three rotary file systems [TRN (26.04v), PTUltimate (25.08v), and VDW.R (25.06v)]. The debris extruded apically was collected in Eppendorf tubes of known weights. After preparation, the tubes were placed in an incubator at 70°C for five days to evaporate the distilled water. The tubes filled with debris were then weighed again, and the net weight of the extruded debris was calculated in grams (g) by subtracting the initial weight from the final weight. The data were analyzed using one-way ANOVA test. Results: There was no significant difference in the amount of debris extruded apically by the three shaping files ( p > 0.05). The highest amount of debris extruded apically was 0.9534 g for PTUltimate. VDW.R extruded the minimum amount of debris apically, with 0.1833 g. Conclusion: All rotary files have caused apical debris extrusion. Even though there was no significant difference among the files, the VDW.R file extruded less debris compared to other file systems.   How to cite this article: Eskibağlar M, Yeniçeri Özata M, Timis Ll. Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion. Int Dent Res 2023;13(S1):26-31. https://doi.org/10.5577/idr.2023.vol13.s1.4   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Apically extruded debris, nickel-titanium file, root canal preparation, ProTaper Ultimate, TruNatomy, VDW.Rotate
    Mehmet Eskibağlar, Merve Yeniçeri Özata, Lucia lacobina Timis
    15.10.2023
    26-31
    Abstract Views: 4904 Download: 1361 DOI 10.5577/idr.2023.vol13.s1.4
  • Evaluation of ProTaper Ultimate, ProTaper Next, and ProTaper Gold system instruments for debris and irrigant extrusion

    Aim: The aim of this investigation was to compare recently released ProTaper Ultimate system (PTU) instruments, ProTaper Next (PTN), and ProTaper Gold (PTG) in terms of apically extruded debris and irrigant. Methodology: Forty-five human extracted mandibular molar teeth had their mesial roots decoronated. The roots were then split into three groups (n = 15) for the root canal preparation system: PTU, PTG, and PTN. Using the Myers and Montgomery technique, the roots were embedded in the experimental apparatus to collect and analyze the extruded material. The root canals were prepared according to the manufacturer's instructions. The weights of the extruded debris and irrigant were analyzed using ANOVA with post hoc Tukey tests to evaluate the level of significance (p < 0.05). Results: The PTU group produced the least amount of irrigant and debris. The amount of extruded irrigant produced by each group was statistically significantly comparable (p > 0.05). PTU produced lower debris weight than PTG in terms of debris extrusion (p < 0.05). For apically extruded debris, no statistically significant differences were observed among the other comparison pairs (p > 0.05). Conclusion: For apically extruded irrigant extrusion, the investigated instrument systems produced comparable results. Similar to PTG, the recently introduced PTU method showed promising findings.
    Irrigant extrusion, debris, rotary instruments, nickel-titanium, ProTaper Ultimate, ProTaper Next, ProTaper Gold
    Esma Sarıçam, Sümeyye Türker Konukman
    31.12.2025
    153-158
    Abstract Views: 609 Download: 235 DOI 10.5577/intdentres.614
  • Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles

    Aim: To compare the amount of apically extruded debris using Reciproc (R25) file with different reciprocal angles. Methodology: In this research, 60 extracted mandibular premolars with a single root, a single canal, and a single apical foramen were used. Specimens, the working length of which was determined by a stainless steel 10-K file, were randomly distributed into three experimental groups (n = 20) as follows: Group 1 150° counterclockwise (CCW)-30° clockwise (CW); Group 2 180° CCW-60° CW; and Group 3 210° CCW-90° CW. For the irrigation, 10 mL of distilled water was administered via syringe pump. The extruded debris was collected into Eppendorf tubes tared in advance. The distribution of data was analyzed using a Shapiro-Wilk test. A Kruskal-Wallis H test was used for statistical analysis. The null hypothesis is no significant difference between the groups in terms of the amount of apical extrusion of debris. Results: There was no statistically significant difference between the groups with regard to amount of apical extrusion of debris (p>0.05). Nevertheless, the highest average amount of extrusion of debris was detected in group 1, and the lowest in group 3. Conclusion: According to the results of this study, different reciprocal angles during chemomechanical preparation has no significant effect on the amount of apical extrusion of debris.   How to cite this article: Çelik N, Kaya S, Adıgüzel Ö. Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles. Int Dent Res 2021;11(Suppl.1):63-6. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.10   Linguistic Revision:  The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
    Reciproc, kinematics, reciprocation, debris extrusion
    Nezif Çelik, Sadullah Kaya, Özkan Adıgüzel
    30.09.2021
    63-66
    Abstract Views: 1855 Download: 679 DOI 10.5577/intdentres.2021.vol11.suppl1.10
1 - 12 of 12 items

Journal Issue

Vol. 16 (2026): International Dental Research
Vol. 16 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 16 (2026): International Dental Research
  • Vol. 16 No. S1 (2026): International Dental Research
  • Vol. 16 No. Advanced Online (2026): International Dental Research
2025
  • Vol. 15 No. 3 (2025): International Dental Research
  • Vol. 15 No. 2 (2025): International Dental Research
  • Vol. 15 No. 1 (2025): International Dental Research
2024
  • Vol. 14 No. 3 (2024): International Dental Research
  • Vol. 14 No. Suppl. 1 (2024): International Dental Research
  • Vol. 14 No. 2 (2024): International Dental Research
  • Vol. 14 No. 1 (2024): International Dental Research
  • 2024: Advanced Online
2023
  • Vol. 13 No. S1 (2023): International Dental Research
  • Vol. 13 No. 3 (2023): International Dental Research
  • Vol. 13 No. 2 (2023): International Dental Research
  • Vol. 13 No. 1 (2023): International Dental Research
2022
  • Vol. 12 No. Suppl. 1 (2022): International Dental Research
  • Vol. 12 No. 3 (2022): International Dental Research
  • Vol. 12 No. 2 (2022): International Dental Research
  • Vol. 12 No. 1 (2022): International Dental Research
  • No. Accepted Articles: International Dental Research
Show more Show less
2021
  • Vol. 11 No. 3 (2021): International Dental Research
  • Vol. 11 No. Suppl. 1 (2021): International Dental Research
  • Vol. 11 No. 2 (2021): International Dental Research
  • Vol. 11 No. 1 (2021): International Dental Research
2020
  • Vol. 10 No. 3 (2020): International Dental Research
  • Vol. 10 No. 2 (2020): International Dental Research
  • Vol. 10 No. 1 (2020): International Dental Research
2019
  • Vol. 9 No. 3 (2019): International Dental Research
  • Vol. 9 No. 2 (2019): International Dental Research
  • Vol. 9 No. 1 (2019): International Dental Research
2018
  • Vol. 8 No. 3 (2018): International Dental Research
  • Vol. 8 No. 2 (2018): International Dental Research
  • Vol. 8 No. 1 (2018): International Dental Research
2017
  • Vol. 7 No. 3 (2017): International Dental Research
  • Vol. 7 No. 2 (2017): International Dental Research
  • Vol. 7 No. 1 (2017): International Dental Research
2016
  • Vol. 6 No. 1 (2016): Volume 6, No 1, 2016
2012
  • Vol. 2 No. 3 (2012): Volume 2, No 3, 2012
  • Vol. 2 No. 1 (2012): Volume 2, No 1, 2012
  • Vol. 2 No. 2 (2012): Volume 2, No 2, 2012
2011
  • Vol. 1 No. 3 (2011): Volume 1, No 3, 2011
  • Vol. 1 No. 2 (2011): Volume 1, No 2, 2011
  • Vol. 1 No. 1 (2011): Volume 1, No 1, 2011

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Congresses & Events

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 1073 873
h-index 13 11
i10-index 18 12
0 50 100 150 200 250
  • 37 2019
  • 50 2020
  • 71 2021
  • 112 2022
  • 146 2023
  • 140 2024
  • 202 2025
  • 199 2026
Citations per year
Year Citations
2019 37
2020 50
2021 71
2022 112
2023 146
2024 140
2025 202
2026 (to date) 199

2026 counts citations recorded so far this year.

icmje and ithenticate

Indexed in CiteLink

EBSCO

TR Dizin Journal List

Keywords

Information

  • For Readers
  • For Authors
  • For Librarians

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo
Most Read Articles
  • Endodontic Irrigation Solutions: A Review
    13336 13336 views 2017
  • Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex
    11127 11127 views 2021
  • Areas for use of PEEK material in dentistry
    9560 9560 views 2018
  • Comparative evaluation of the responses from ChatGPT-5, Gemini 2.5 Flash, and DeepSeek-V3.1 chatbots to patient inquiries about endodontic treatment in terms of accuracy, understandability, and readability
    7864 7864 views 2025
  • Evaluation of the color stability and surface roughness of dual-cure, bulk-fill composites
    7181 7181 views 2021

announcement

Announcement

visitors

Visitors 

Flag Counter

Web Analytics

View My Stats

Most Cited Articles
  • Areas for use of PEEK material in dentistry
    162 162 citations 2018
  • Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review
    61 61 citations 2011
  • The Latest Developments Related to Composite Resins
    44 44 citations 2017
  • PEEK in dentistry, properties and application areas
    37 37 citations 2020
  • A Literature Review of Self Adjusting File
    31 31 citations 2011

Browse

  • Categories
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
logo
E-ISSN: 2146-1767

Download App

Contact

Publisher: International Dental Research

Email: info@dental-research.com

Website: www.dental-research.com

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

ElsevierCiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2011-2026 | International Dental Research. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information