Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles

Nezif Çelik (1) , Sadullah Kaya (2) , Özkan Adıgüzel (3)
(1) Harran University, Faculty of Dentistry, Departmant of Endodontics, Şanlıurfa, Turkey , Türkiye
(2) Dicle University, Faculty of Dentistry, Departmant of Endodontics, Diyarbakır, Turkey , Türkiye
(3) Dicle University, Faculty of Dentistry, Department of Endodontics, Diyarbakir, Turkey , Türkiye

Abstract

Aim: To compare the amount of apically extruded debris using Reciproc (R25) file with different reciprocal angles.


Methodology: In this research, 60 extracted mandibular premolars with a single root, a single canal, and a single apical foramen were used. Specimens, the working length of which was determined by a stainless steel 10-K file, were randomly distributed into three experimental groups (n = 20) as follows: Group 1 150° counterclockwise (CCW)-30° clockwise (CW); Group 2 180° CCW-60° CW; and Group 3 210° CCW-90° CW. For the irrigation, 10 mL of distilled water was administered via syringe pump. The extruded debris was collected into Eppendorf tubes tared in advance. The distribution of data was analyzed using a Shapiro-Wilk test. A Kruskal-Wallis H test was used for statistical analysis. The null hypothesis is no significant difference between the groups in terms of the amount of apical extrusion of debris.


Results: There was no statistically significant difference between the groups with regard to amount of apical extrusion of debris (p>0.05). Nevertheless, the highest average amount of extrusion of debris was detected in group 1, and the lowest in group 3.


Conclusion: According to the results of this study, different reciprocal angles during chemomechanical preparation has no significant effect on the amount of apical extrusion of debris.


 


How to cite this article: Çelik N, Kaya S, Adıgüzel Ö. Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles. Int Dent Res 2021;11(Suppl.1):63-6. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.10


 


Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.

Full text article

Generated from XML file

Authors

Nezif Çelik
dtnezifcelik@gmail.com (Primary Contact)
Sadullah Kaya
Özkan Adıgüzel
Çelik, N., Kaya, S., & Adıgüzel, Özkan. (2021). Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles. International Dental Research, 11(Suppl. 1), 63-66. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.10
Copyright and license info is not available

Article Details

How to Cite

Çelik, N., Kaya, S., & Adıgüzel, Özkan. (2021). Comparing the effect of Reciproc R25 rotary file system on the amount of apical extrusion of debris via using it with different reciprocal angles. International Dental Research, 11(Suppl. 1), 63-66. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.10

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1 2 3 4 > >> 

Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation

Ahmet Akay, Özkan Adıgüzel, Seda Erkan Akay, Sadullah Kaya
Abstract View : 292
Download :261