The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments

Elsayed Abdallah Abdel-Khalek(1), Nesreen El Mekawy(2)
(1) Mansoura University, Faculty of Dentistry, Department of Removable Prosthodontics, Mansoura, Egypt,
(2) Mansoura University, Faculty of Dentistry, Department of Removable Prosthodontics, Mansoura, Egypt

Abstract

Aim: The aim was to evaluate the efficacy of attachment placement on initial stability and bone height changes for immediately loaded single-implants retaining mandibular overdentures.


Methodology: Twenty edentulous patients were recruited for this study; 9 females (45.0%) and, 11 males (55.0%)  (age ranged from 59.0 to 70.0 year). Single endoosseos implant was inserted in the mandibular midline region. Immediately after surgery; Locator abutment was secured on the implant and the male housing was connected intraorally using direct pick-up procedure. Marginal bone height measurements and implant stability values were assessed at the time of implant placement (baseline), 2,4,6,8, 12, 24 weeks then every 6-month interval up to 18 months post-implant placement.   


Results: The implant stability values decreased markedly from the baseline, during 4 weeks and, then increased gradually until reaching the initial values after 12 weeks followed by continuous increase to study’s end (p<0.05). The peri-implant marginal bone level revealed an acceptable range of bone loss with a statistically significant differences between different follow-up times and it continued to the end of the study (p<0.05).


Conclusion: Retaining an overdenture by immediately loaded single implant could be a successful treatment option for mandibular edentulous arches, especially in people with limited financial resources. The use of Locator attachment seemed to have a favorable effect on implant stability and marginal bone around immediately loaded single implant mandibular overdenture after 18-months of function.


 


How to cite this article: Abdel-Khalek EA, El Mekawy N. Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. Int Dent Res 2018;8(3):96-104.


 


Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.

Full text article

Generated from XML file

Authors

Elsayed Abdallah Abdel-Khalek
elsayed_abdallah@mans.edu.eg (Primary Contact)
Nesreen El Mekawy
Abdel-Khalek, E. A., & El Mekawy, N. (2018). The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. International Dental Research, 8(3), 96-104. https://doi.org/10.5577/intdentres.2018.vol8.no3.1

Article Details

How to Cite

Abdel-Khalek, E. A., & El Mekawy, N. (2018). The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. International Dental Research, 8(3), 96-104. https://doi.org/10.5577/intdentres.2018.vol8.no3.1
Smart Citations via scite_

Similar Articles

You may also start an advanced similarity search for this article.

No Related Submission Found