The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments

Elsayed Abdallah Abdel-Khalek(1), Nesreen El Mekawy(2)
(1) Mansoura University, Faculty of Dentistry, Department of Removable Prosthodontics, Mansoura, Egypt, Egypt
(2) Mansoura University, Faculty of Dentistry, Department of Removable Prosthodontics, Mansoura, Egypt, Egypt

Abstract

Aim: The aim was to evaluate the efficacy of attachment placement on initial stability and bone height changes for immediately loaded single-implants retaining mandibular overdentures.


Methodology: Twenty edentulous patients were recruited for this study; 9 females (45.0%) and, 11 males (55.0%)  (age ranged from 59.0 to 70.0 year). Single endoosseos implant was inserted in the mandibular midline region. Immediately after surgery; Locator abutment was secured on the implant and the male housing was connected intraorally using direct pick-up procedure. Marginal bone height measurements and implant stability values were assessed at the time of implant placement (baseline), 2,4,6,8, 12, 24 weeks then every 6-month interval up to 18 months post-implant placement.   


Results: The implant stability values decreased markedly from the baseline, during 4 weeks and, then increased gradually until reaching the initial values after 12 weeks followed by continuous increase to study’s end (p<0.05). The peri-implant marginal bone level revealed an acceptable range of bone loss with a statistically significant differences between different follow-up times and it continued to the end of the study (p<0.05).


Conclusion: Retaining an overdenture by immediately loaded single implant could be a successful treatment option for mandibular edentulous arches, especially in people with limited financial resources. The use of Locator attachment seemed to have a favorable effect on implant stability and marginal bone around immediately loaded single implant mandibular overdenture after 18-months of function.


 


How to cite this article: Abdel-Khalek EA, El Mekawy N. Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. Int Dent Res 2018;8(3):96-104.


 


Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.

Full text article

Generated from XML file

Authors

Elsayed Abdallah Abdel-Khalek
elsayed_abdallah@mans.edu.eg (Primary Contact)
Nesreen El Mekawy
Abdel-Khalek, E. A., & El Mekawy, N. (2018). The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. International Dental Research, 8(3), 96-104. https://doi.org/10.5577/intdentres.2018.vol8.no3.1

Article Details

How to Cite

Abdel-Khalek, E. A., & El Mekawy, N. (2018). The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments. International Dental Research, 8(3), 96-104. https://doi.org/10.5577/intdentres.2018.vol8.no3.1
Smart Citations via scite_

Similar Articles

You may also start an advanced similarity search for this article.

No Related Submission Found